My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG D 2025-08-06
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG D
>
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG D 2025-08-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:18:03 AM
Creation date
8/4/2025 3:07:42 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG D
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e. Expected operating state and confirmation of proper operation indicated at the smoke <br />control panel within 60 seconds. <br />9. Smoke control power and control wiring is fully enclosed in continuous raceways in accordance <br />with IBC Section 909.12.2. The equipment, control wiring, power wiring, and ductwork is <br />protected to a 2-hour fire -resistance rating as prescribed in IBC Section 909.20.6.1. <br />10. The smoke control system operated correctly under normal and secondary power. The <br />pressurization system continued to operate correctly under transfer to secondary power (tap - <br />ahead). <br />11. A weekly self -test was successfully performed. A fire alarm event during the weekly self -test <br />resulted in over -ride of the weekly self -test and automatic operation of the smoke control system <br />and initiation of the fire alarm notification devices. Testing also demonstrated that the weekly <br />self -test did not over -ride automatically or manually initiated smoke control events. <br />12. The printer for the fire alarm system has been installed in the Building B fire alarm room. <br />FINAL COMMENTS: <br />The Stair 1 and Stair 2 fire alarm wiring serving the smoke control fan and damper was originally planned <br />to run from the fire alarm room to Stair 1 and Stair 2 in the PT deck. However, the conduits were damaged <br />and unusable. Therefore, both Stair 1 and Stair 2 smoke control fire alarm wiring has been revised to <br />utilize separate paths from the fire alarm room to each associated stair enclosure as follows: wiring runs <br />within conduit attached to the parking garage ceiling utilizing 2-hour fire rated wire within metallic <br />raceway thus maintaining the required separation and protection of the wiring. <br />The construction team will assemble smoke control O&M, design, and test documents for transition to <br />the building operations team. <br />Based on the findings above and by personal knowledge and on -site observation, the stair pressurization <br />systems for Stair 1 and Stair 2 of Four Corners Building D have been satisfactorily tested as documented <br />in this report and the attached test forms. <br />Prepared by: oD�WA <br />WAS� ti% <br />Allen Engineering, PLLC I �� <br />'A 31713 <br />Travis E. Allen, P.E. F 'S"91oNA�RENG\�� <br />Member <br />Smoke control special inspection Final Report 2024.2.15 -Four Corners Bldg D. docx <br />Attachments: Test forms <br />Cc: Steve Sullivan (email) <br />E Engineering Your Success 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.