B2010-048—Plan Review Response <br /> March 11,2021 <br /> 7. On Detail 5/S8,appears to be a special boundary element detail.Please verify that cross-ties are <br /> extending a minimum of 12"into the foundation,as it does not appear to be captured in the detail or <br /> shear wall elevations.ACI 318-1418.10.6.4. <br /> The cross ties in the boundary zones will extend 12"into the foundation. Detail 5/58 has been updated to <br /> show the cross ties continuing 12"into the foundation. <br /> If you have any further questions or comments please call our office at 206.523.0024. <br /> Sincerely, <br /> C SCm_ <br /> Davido Consulting Group,Inc. 4�� of wAsy� , _ L iI',tico 1�� <br /> — - 37334 tip,�q' <br /> �C;IA` cruRA L ENG\ �v <br /> Eric Maunder, PE Matthew C.Schmitter, PE,S SS/ONAL E� <br /> Structural Engineer IV Vice President/Principal <br /> Davido Consulting Group,Inc. <br /> Page 2 <br />