My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG E 2025-08-06
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG E
>
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG E 2025-08-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:58:29 AM
Creation date
8/4/2025 3:08:09 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG E
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
331
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM: SPF-1 <br />AREA SERVED: STAIR #1 <br />Fan Information <br />1. <br />Rated voltage: 208 <br />2. Actual Operating Voltage: 211 <br />3. <br />Rated Amperage: 5.6 <br />4. Actual Operating Amperage: 1.8 <br />5. <br />Fan RPM: 30.0 HZ <br />6. Number Fan Belts: DIRECT DRIVE <br />7. <br />Fan Belts Condition: DIRECT DRIVE <br />Measurements Taken <br />Floor <br />Inches H2O <br />Floor <br />Inches <br />H2O <br />Floor <br />Door Force <br />(LBS) <br />Floor <br />Door Force <br />(LBS.) <br />G-OUTSIDE <br />0.18 <br />5TH <br />018 <br />G- <br />OUTSIDE <br />8 <br />5TH <br />22 <br />G-PARKING <br />0.18 <br />6TH <br />018 <br />G- <br />PARKING <br />8 <br />6TH <br />22 <br />2ND <br />0.18 <br />2ND <br />22 <br />3RD <br />0.18 <br />3RD <br />23 <br />4TH <br />0.18 <br />4TH <br />23 <br />General <br />YES <br />NO <br />N/A <br />1. <br />Do stair shafts have flush? CFM <br />❑ <br />❑ <br />2. <br />Were measurements taken from atmospheric pressure? <br />® <br />❑ <br />❑ <br />3. <br />Were measurements taken from shaft and the main occupied area? <br />® <br />❑ <br />❑ <br />4. <br />What was static pressure? _0.18 in. H2O <br />5. <br />Were readings taken at every 5th floor? <br />® <br />❑ <br />❑ <br />6. <br />Do fans operate when fire alarm is activated? <br />® <br />❑ <br />❑ <br />7. <br />Do fans operate on emergency power? <br />❑ <br />❑ <br />8. <br />If no sprinklers, is elevator shaft pressure 0.15 in H2O or greater? <br />❑ <br />❑ <br />9. <br />Do elevator shaft pressures measure 0.10 in H2O, in 100% automatic <br />❑ <br />❑ <br />sprinklered building? <br />10.All <br />doors (stairway and elevator) operate correctly? <br />® <br />❑ <br />❑ <br />11. <br />System can be operated manually? <br />® <br />❑ <br />❑ <br />12. <br />Does life safety core type building have 0.05 in H2O between pressurized <br />❑ <br />❑ <br />core and tenant area? <br />13.Are <br />gaskets in good condition on stair and elevator doors? <br />® <br />❑ <br />❑ <br />14. <br />Do all dampers, controls work properly on shaft pressurization system? <br />® <br />❑ <br />❑ <br />15. <br />Do stair shaft pressures measure 0.10 in H2O? <br />® <br />❑ <br />❑ <br />Additional Measurements, Calculations and Comments: <br />EMERGENCY POWER TEST PERFORMED BY OTHERS. <br />Shaft Pressurization Page 2 of 4 <br />