Laserfiche WebLink
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> PLUMB 02- JASON <br /> 2/28/2022 2/28/2022 GROUND MORRISSEY APPROVAL eTRAKiT Inspection Request <br /> WORK/SLAB <br /> Notes: <br /> 2/24/2022 3:47 PM Joseph Stephanson <br /> Contact Name:Joseph Stephanson <br /> Site Address:2216 GRAND AVE <br /> Phone:2065959401 <br /> e-Mail:digits@uw.edu <br /> (2/28/2022 12:23 PM JJM) <br /> -Underground plumbing ok. <br /> PERMIT EXTENSION SHEYENNE EXTENSION <br /> 9/20/2022 9/20/2022 (REASON <br /> MORTON APPROVED <br /> REQUIRED) <br /> Notes: <br /> EXTENSION REQUESTED BY TYLER 425-948-5763 <br /> TYLER@GALLAGHERCONSTRUCTIONLLC.COM <br /> 9/21/2022 9/21/2022 PLUMB 03-ROUGH JASON CORRECTION see notes <br /> IN MORRISSEY REQUIRED <br /> Notes: <br /> 9/20/2022 2:14 PM GALLAGHER CONSTRUCTION LLC <br /> Contact when in route <br /> Contact Name:GALLAGHER CONSTRUCTION LLC <br /> Site Address:2216 GRAND AVE <br /> Phone:4257484468 <br /> e-Mail:tyler@gallaghercontructionllc.com <br /> -No test on drain,waste and vent system.Test waste system to 10'above highest fixture or through roof vent per 2018 UPC 712.2 Water Test.-Replace <br /> medium sweep fittings where needed with approved 1/8th bend or long sweep fittings per 2018 UPC 706.0 Changes in Direction of Drainage Flow.- <br /> Support ABS drain waste and vent every 4'on horizontal runs at each floor and mid story per 2018 UPC 313.3 Suspended Piping.-Install in wall <br /> mechanical vent box or extend outside wall for downstairs sink.All traps require a vent per 2018 UPC 1002.1 Vent Pipes.-Support pex pipe every 32"on <br /> the horizontal per mid story and at each floor per 2018 UPC 7.0 Hangers and Supports.-Rough in upstairs AW trap to 6"minimum above the floor with <br /> tailpiece between 18"and 30"per 2018 UPC 804.1 Standpipe Receptors.-Ensure water distribution system is sized per 2018 UPC 610.0 Size of Potable <br /> Water Piping.-Before final need proof of 91%water heater efficiency.'All plumbing fixtures to be installed per 2018 UPC and on site approved set of <br /> plans!!!*** Make sure to obtain electrical permit before starting any electrical work. <br /> JASON <br /> 9/23/2022 9/23/2022 PLUMB I ROUGHN MORRISSEY NOT READY eTRAKiT Inspection Request <br /> Notes: <br /> 9/22/2022 11:18 AM GALLAGHER CONSTRUCTION LLC <br /> Call Tyler Barberi when in-route to job <br /> 425-948-5763 <br /> Contact Name:GALLAGHER CONSTRUCTION LLC <br /> Site Address:2216 GRAND AVE <br /> Phone:4257484468 <br /> e-Mail:Tyler@gallaghercomstructionllc.com <br /> Spoke with Tyler.Corrections have not been completed yet. <br /> I <br /> Printed:Wednesday,06 August, 2025 2 of 3 rk <br /> SUPERION <br />