Laserfiche WebLink
Enclosures CONTROL UNIT FEATURES <br /> The ARIES NETLink offers two enclosure sizes, 2-Tier Seamless Integration with Specialty Detectors <br /> and 3-Tier, for both main and expansion enclosures. The SmartOne loop protocol interface cards enable the <br /> enclosures accommodate the MCB, PMU/PSU, Expan- ARIES NETLink to seamlessly integrate with specialty <br /> sion Card Cages and Batteries. The enclosures are sized detectors. AIR-Intelligence Air Sampling Smoke Detec- <br /> to fit between standard 16"-spaced wall studs and can tors (ASD) and ORION XT High Sensitivity Smoke <br /> accommodate a pair of 12 VDC12-AH or 17-AH SLA Detectors (HSSD) connect via Addressable Protocol <br /> batteries (max. 40-AH). The enclosures are painted red, Interface Cards (APIC) and PEGAsys Addressable Loop <br /> rated NEMA 1 and constructed from 16 AWG cold rolled Modules (PALM) respectively and report pre-alarms and <br /> steel per ASTM A-366. All Kidde enclosures utilize a alarms in a manner analogous to SmartOne smoke <br /> common key. Despite its compact dimensions, the enclo- detectors. AlarmLine Integrating Linear Heat Detector <br /> sure allows a minimum of 1.5 in. (38 mm)of wiring space sensors (LHD) connect via AlarmLine Addressable Mod- <br /> between the wall and any wiring terminal. Multiple knock- ules (AAM) and report pre-alarms and alarms similar to a <br /> outs provide flexibility in wiring entry. Smart-One heat detector. Fixed Temperature Linear Heat <br /> Dead Front Covers Sensor cables (LHS) connect via Addressable Input <br /> A sheet-steel dead-front cover may optionally be Modules (AI) and report point alarms. <br /> mounted between the door and electronics to prevent Field Programming Options <br /> unwanted access to the electronics. With the dead-front The ARIES NETLink Configuration Software (ACT8000) <br /> installed, an operator has access only to the user inter- tool is used to program the control unit for each individual <br /> face. A blanking plate (included) may be removed if an site-specific application. Programming is for control-by- <br /> integrated LED Annunciator is present. The dead front is event scenarios and consists of entering a series of con- <br /> typical in ULC/cUL applications. ditional control statements that logically join initiating <br /> Enclosure Trim Ring points to control-unit-based outputs and remote control <br /> A sheet-steel red-enamel finished trim ring may be modules. Each SmartOne field device can be assigned a <br /> mounted around a semi-flush ARIES NETLink enclosure location message of up to 40 characters via the configu- <br /> to enhance the Control Unit's aesthetic appeal after ration tool. A USB Device Port is available to connect a <br /> installation. laptop computer for application upload. <br /> The ARIES NETLink provides programming flexibility to <br /> Material of Construction: 16 gauge (0.053 in. or 1.35 prohibit the silencing of releasing service signals via the <br /> mm) rolled sheet steel <SIGNAL SILENCE> key and to set the maximum auto- <br /> Enclosure Rating/ NEMA 1 matic delay for the release operation in accordance with <br /> Degree of Protection: ULC S527-11 requirements. A Releasing Service Signal <br /> Silence Station is available for purchase and should be <br /> Color: Red installed near the control unit in these applications. <br /> Enclosure Dimensions <br /> (H x W x An AutoLearn routine that creates a general alarm (one- <br /> • 3-Tier: 31-1/2 x 14-3/8 x 5-3/8 (in.) input-activates-all outputs) application can be invoked <br /> 81- x x 1 -3/ (x 5- from the User Interface to speed the configuration pro- <br /> cess. A more sophisticated Auto-Setup routine which <br /> 22-1/2 x 14-3/8 x 5-3/8 (in.) automatically configures the control unit for a typical <br /> • 2-Tier: 572 x 365 x 137 (mm) waterless fire-suppression system can also be invoked. <br /> Dead Front Dimensions Automatic SLC Device Testinq <br /> (H x W): The ARIES NETLink features an exclusive automatic <br /> • 3-Tier: 31-1/3 x 14 (in.) SLC device testing protocol. With this cutting edge super- <br /> 796 x 356 (mm) visory technology, the control unit routinely checks all <br /> SLC devices in groups of 32 for operational status. If a <br /> 2-Tier: 22-5/8 x 14 (in.) group fails, the control unit then interrogates at lower <br /> • 567 x 355 (mm) level in that group and pin-points and reports the mal- <br /> Trim Ring Dimensions: functioning device on the User Interface within seconds. <br /> • 3-Tier: 17-1/2 x 34-5/8 (in.) Duplicate Address Detection <br /> 444 x 879 (mm) Electronic device addressing is via the Handheld Pro- <br /> grammer (HHP). The fully-digitized ARIES NETLink <br /> • 2-Tier: 17-1/2 x 25-5/8 (in.) Control Unit protocol has the ability to monitor the SLC <br /> 444 x 651 (mm) for devices with duplicate addresses. Should such dupli- <br /> cation be detected, the control unit displays these <br /> addresses on the User Interface — thereby reducing the <br /> overall configuration time. <br /> - 9 - <br />