HORIZONTAL AND VERTICAL DETECT-A-FIRE <br /> Table S: D-A-F Response Time Index (RTI) and Spacing <br /> Model Contact Temperature Response Time RTI RTI Rated Old Rated <br /> No. Configuration Operation (Set Point) Index(ft-s)1/2 Classification Spacing Spacing <br /> 270210 Horizontal <br /> Flush Mount Normally Open ° ° ° ° (20 X 20)ft (25 x 25)ft <br /> 27021-1 Horizontal <br /> (Close on Rise) 140 F(60 C),160 F(71 C) 110 Quick (6 x 6)m (8 x 8)m <br /> Surface Mount <br /> 270210 Horizontal <br /> Flush Mount Normally Open 190°F(88°C°),210°FF(990C), (25 x 25)ft (25 x 25)ft <br /> (Close on Rise) 225 F(107 C),275 F(135 C), 140 Fast (8 x 8)m (8 x 8)m <br /> 27021-1 Horizontal 325°F(163°C) <br /> Surface Mount <br /> 27121-0 Vertical <br /> Brass Head 140-F(60-C),160-F(71-C), 99(140°F, 160°F) <br /> 190 F(88 C),210 F(99 C), <br /> Vertical Normally Open 225°F(1070C),275°F(1350C), 148(190°F,210°F, (30 X 30)ft (25 x 25)ft <br /> 27121 20 Stainless Head (Close on Rise) 325°F(163°C),360°F(1821C), 225°F,275°F,325°F, V Fast (9 x 9)m (8 x 8)m <br /> 450°F(2320C),500°F(2600C), 360°F,450°F,Vertical Stainless 600°F(3160C),725°F(385°C) 600°F,725-F) <br /> F) <br /> 28021-5 Coupling Head <br /> Note:Spaces shown are distances between detectors on smooth ceilings,the distances from partitions or walls would be half that shown. <br /> Authority Having Jurisdiction(AHJ)should be consulted before installation. <br /> DETECT-A-FIRE MOUNTING <br /> D-A-F detectors are not position sensitive. Horizontal and vertical detectors refer to the most common mounting configuration for that <br /> detector. However each type can be mounted either horizontally or vertically depending on the application and installation requirements. <br /> Table 6: Mounting and Hazardous Location Class Table 7: Derating Factor for Ceiling Height <br /> Fitting required Heat Detector Spacing Reduction Based on Ceiling Height <br /> Model Number Hazardous for UL&ULC Ceiling Height Above Up to and Including <br /> (Vertical Only) Location Listing and FM Derating <br /> Approval m ft m ft Factor <br /> 27120-2 Class I,Groups 0 0 3.05 10 1.00 <br /> 27121-20 A,B,C and D; Mount detector to a 3.05 10 3.66 12 0.91 <br /> 28020-3 Class II,Groups suitable listed fitting 3.66 12 4.27 14 0.84 <br /> 28021-5 E,F and G in accordance with <br /> National Electric 4.27 14 4.88 16 0.77 <br /> Class I,Groups Code and/or local 4.88 16 5.49 18 0.71 <br /> 27120-0 B,C and D; authority having 5.49 18 6.10 20 0.64 <br /> 27121-0 Class II Groups jurisdiction. <br /> E,F and G 6.10 20 6.71 22 0.58 <br /> 6.71 22 7.32 24 0.52 <br /> 7.32 24 7.93 26 0.46 <br /> 7.93 26 8.54 28 0.40 <br /> 8.54 28 9.14 30 0.34 <br /> This table outlines the derating factor required depending on ceiling height <br /> based on NFPA 72 guidelines for D-A-F detector installation. <br /> CONSTRUCTION <br /> • Stainless steel shell sensing element. Cold rolled steel mounting facility. Off-White finish. <br /> • #18 AWG Teflon TM insulated wire is used on detectors exposed to temperatures up to 375°F. <br /> • #16 AWG TGGT insulated wire is used on detectors exposed to temperatures above 375°F. <br /> MODIFICATIONS <br /> • Add ULC Label to any temperature setting. <br /> • Add fluorocarbon coating for better corrosion resistance on select models and temperatures. <br /> (Models 27120-22, 27121-20, 28020-3, 28021-5. Maximum temperature is 5000F.) <br /> • Add extended leadwires on select models and temperatures. <br /> 4 F-12-0-001 <br /> FENWAL Effective: June 2020 <br /> CONTROLS <br />