Laserfiche WebLink
19011 Wood-Sno Road NE,Suite 100 <br /> Woodinville,WA 98072-4436 <br /> Phone:425-814-8448 <br /> E NGI[ EE•RI1\ Fax 425-821-2120 <br /> Pacific Ridge Hornes Revision Date: 1/11/2021 <br /> Thelon (Elevations A & B) <br /> Criteria _ <br /> Code: 2018 IBC <br /> Allowable Stress Design(ASD) <br /> Seismic Design: ASCE 7-16: 12.8 Equivalent Lateral Force Procedure <br /> Wind Design: ASCE 7-16:Ch.28 Envelope Procedure, Low Rise <br /> Risk Category: II-Other Structures v Table 1.5-1 <br /> Snow Importance Factor lS = 1.00 Table 1.5-2 <br /> Ice Importance Factor-Thickness l; = 1.00 Table 1.5-2 <br /> Ice Importance Factor-Wind I ,, = 1.00 Table 1.5-2 <br /> Seismic Importance Factor le = 1.00 Table 1.5-2 <br /> Spectral Response, Short Period SS = 1,500 (Mapped) <br /> Spectral Response, 1-s Period S, = 0.500 (Mapped) <br /> site Class assumed,no Geotechnical Report <br /> Site Class: <br /> D v Table 20.3-1 <br /> Site Coefficient Fd = 1.20 Table 11.4-1 <br /> Site Coefficient F„ = 1.80 Table 11.4-2 <br /> Structural Systems: <br /> Light framed walls with shearpanels <br /> All other structural systems ► Ti = 6 (Figs. 22-14 thru 22-17) <br /> Response Modification Coefficient R = 6.5 Table 12.2-1 <br /> Overstrength Factor DO = 3 Table 12.2-1 <br /> Deflection Amplification Factor Cd = 4 Table 12.2-1 <br /> Basic Wind Speed:_ too mph <br /> Ex Section 26.7.3 osure s v <br /> Exposure to Wind: P �� <br /> Topographical Factor Kn= 1.00 <br /> Date:4/6/2022 <br /> Page: L1.1 <br />