Laserfiche WebLink
A I B I c I D I E I F I G I H <br /> AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES <br /> L)4 °0 <br /> -.,.--.:.,':-.-,'„:,,,'-.::c,,-',--:'--:A''.'....‘ <br /> -2 4_ki°..,,•'-'' <br /> 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY <br /> ,:4— DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY <br /> "'" '' ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES <br /> SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. <br /> THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, <br /> 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS & RULES OF THE <br /> [ THE MULTI WIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH <br /> — `l • <br /> BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. — <br /> (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY <br /> 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT <br /> LABORATORY SHALL LIST ALL OF WORK. <br /> r EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL <br /> ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA <br /> cN ` _ # 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, N <br /> - A` STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. <br /> 4 . INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED <br /> Fe 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER CONDITIONING <br /> C/Ty i AT THE UL LISTED LOCATION PROVIDED INVERTER. <br /> — /Jer 0F 202 "n BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF — <br /> UL LISTED GROUNDING HARDWARE. <br /> I?j F/j ,r� �a ANY KIND, OR UPS. <br /> /t�S`p�,�IQF `Y ` .. 6. ALL SOLAR MOUNTING FRAMEWORK TO <br /> 6. MODULE FRAMES, RAIL, AND POSTS <br /> IijC,e x.l e , SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. <br /> S. i' ; GROUND CONDUCTORS AND GROUNDED : FOLLOWMANUFACTURERSSuGGESTED <br /> AT THE MAIN ELECTRICAL PANEL. INSTALLATIONPRACTICESANDWIRING <br /> 0, ��` 7. THE DC GROUNDING ELECTRODE SPECIFICATIONS. c, <br /> RESIDENCE PHOTO CONDUCTOR SHALL BE SIZED ALL WORK TO BE IN COMPLIANCE WITH <br /> ACCORDING TO ARTICLE 250.166E & THE INTERNATIONAL BUILDING CODES. <br /> 690.47. (IBC) <br /> • .,f 9. ALL ELECTRICAL WORK TO BE IN <br /> r+ RC ., w <br /> J R iO, COMPLIANCE WITH THE NATIONAL <br /> 0 ., `. I , t "77.- `S` ELECTRIC CODE (NEC). <br /> c k .071 $ 44• !'` G'y <br /> ,,,, .. s ,apt Y' •,� d AZ* <br /> �. <br /> . i <br /> h 7 <br /> :. - rr v <br /> ICON <br /> 01/27/2022 <br /> . A { <br /> STRUCTURAL ONLY <br /> — , - ?a , SHEET INDEX — <br /> lrA 7 <br /> PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM <br /> i <br /> i..� -,, -- PV 2 SITE PLAN PV 6 PLACARD <br /> �. 4 -a „ ;, `�' ,, ,, .4 � .• z <br /> . ' PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED <br /> PV 4 CHIKO MOUNTING <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL - THE INFORMATION CONTAINED MJ N CUSTOM <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Aaron Gay DATE DESIGN <br /> 4rjp S 0 SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 1/25/2022 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> POWER THE RECIPENT'S ORGANIZATION, EXCEPT IN <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 �/j 3904 Federal Ave Everett, WA 98201 PAGE# <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN �p pv 1 <br /> CONSENT FROM SOLGEN POWER. <br />