My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3904 FEDERAL AVE B 2025-08-07
>
Address Records
>
FEDERAL AVE
>
3904
>
3904 FEDERAL AVE B 2025-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2025 3:42:53 PM
Creation date
8/7/2025 3:02:25 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3904
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A I B I C I D 1 E I F 1 G I H <br /> LOAD CALCS-TOTAL AMPS AVAILABLE MAX AC OPERATING CURRENT CALCS <br /> BUS RATING 120% TOTAL MAIN BREAKER MAX BREAKER SIZE <br /> 200A _ X _1_.2_ = 240 - 200A = 40A #OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT <br /> COMBINER BOX PANEL SIZE CALCS 21 x 1.23 = 25.83A <br /> NUMBER OF NUMBER OF NOMINAL OUTPUT TOTAL FUSE SIZE CALCS <br /> CIRCUIT# TOTAL 125 BREAKER SIZE <br /> MODULES MICROINVERTERS CURRENT IN AMPS I AMPS MAX AC OPERATING CURRENT 125% TOTAL FUSE SIZE <br /> _ e- CIRCUIT 1 9 9 x 1.23 = 11.07 x 1.25 = 13.84 = 15A j <br /> CIRCUIT 2 12 12 x i 1.23 = 14.76 ,x 1.25 = 18.45 = 20A 25.83A x i 1.25 x 32.29A I= 35A <br /> NOTES: <br /> UTILITY METER(E) <br /> ITY <br /> 1. 200A UTILITY METER GLOBE ONLY.(EXISTING) <br /> 2. 200A LOAD CENTER.(EXISTING) To UTIL <br /> 3. 60A RATED FUSED LOCKABLE AC DISCONNECT WITH(2) n n GRID(6) <br /> 35A FUSES.(NEW) ,�/, <br /> 4. 125A RATED COMBINER PANEL.(NEW) <br /> ALL CONDUIT SIZES ARE MINIMUM SIZES <br /> ALL WIRE SIZES ARE FOR COPPER WIRE <br /> (2)6 AWG (2)6 AWG EXISTING <br /> N N <br /> (1)8 AWG EGG (1)6 AWG NEUTRAL WIRE -MA IN SERVICE PANEL(E) <br /> I //J <br /> SUPPLY-SIDE INTERCONNECTION <br /> r �NEC 705.11(B) <br /> 4 VERIFY CONDUCTOR SIZE,4/0 AL <br /> j OR 2/0 CU <br /> 0 <br /> If7 2W- <br /> MAIN SERVICE <br /> .. DISCONNECT(E) <br /> CIRCUIT#1-9 ZNSHINE ZXM6-NH120-360M <br /> MODULES <br /> WITH HOYMILES HM-300N MICRO INVERTERS <br /> � r))) 2 <br /> (1)8AWGEGC I` 1 <br /> co (9-1 • • • (2-1 (.1" \`` I (.4 <br /> _L <br /> • • • (2)12 AWG L (1)6 AWG EGC J <br /> J J (1)8AWG EGG <br /> J J <br /> CIRCUIT#2-12 ZNSHINE ZXM6-NH120-360M ` <br /> MODULES <br /> WITH HOYMILES HM-300N MICRO INVERTERS <br /> (I • . • (21 (*1.d <br /> • • • _ _ (2)12 AWG <br /> ti ti ti (1)8 AWG EGC <br /> in Oh <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED M J N NOT TO SCALE <br /> lfri IN THIS PACKET AND SUBSEQUENT CUTSHEETS Aaron Gay DATE: DESIGN <br /> 0 L G <br /> S - N SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER J IZrJ/LOZZ <br /> ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, w <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO,WA 99301 <br /> POWER THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE# 1 <br /> CONNECTION WITH THE SALE AND USE OF THE P:509-931-1663 3 6 3904 Federal Ave Everett, WA 98201 <br /> RESPECTIVE EQUIPMENT,WITHOUT WRITTEN PV <br /> CONSENT FROM SOLGEN POWER. \3 <br />