My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10930 HOLLY DR Geotech Report 2025-08-08
>
Address Records
>
HOLLY DR
>
10930
>
Geotech Report
>
10930 HOLLY DR Geotech Report 2025-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2025 9:49:44 AM
Creation date
8/8/2025 9:44:07 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
10930
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Helix Design Group,Inc.—Greenwood Heating&Air Conditioning,Everett,WA April 22,2022 <br /> Geotechnical Engineering Report Z0219 <br /> The 2018 IBC considers earthquake shaking having a 2 percent probability of exceedance in 50 years <br /> (i.e. a 2475-year return period), as the code-based design requirement. Using the third-party <br /> graphical user interface tools made available by the USGS at https://seismicmaps.org,MGI derived <br /> the design ground motions to be used for design of the structures. Our evaluation used ASCE 7-16 <br /> as the code reference, Risk Category I/II/III, and Site Class D-Stiff Soils. The results of our <br /> evaluation are provided in Table 2 (below): <br /> TABLE 2 <br /> SEISMIC DESIGN PARAMETERS <br /> Parameter Value Basis <br /> Site Class D-Stiff Soils Table 20.3-1 of ASCE 7-16 <br /> Ss 1.398 seismicmaps.org <br /> Fa 1.0A seismicmaps.org <br /> SMs 1.398 =Fa•Ss,2018 IBC Eqn.16-36 <br /> SDs 0.932 =2/3 SMs,2018 IBC Eqn.16-38 <br /> S� 0.498 seismicmaps.org <br /> Fv 1.8 B.c 2018 IBC <br /> SMi 0.896 B.c =Fv•Si,2018 IBC Eqn.16-37 <br /> SDi 0.598 B•C =2/3 SMi,2018 IBC Eqn.16-39 <br /> PGA 0.604g seismicmaps.org <br /> PGAM 0.665g seismicmaps.org <br /> To --c Not applicable <br /> Ts --c Not applicable <br /> Ti. 6 sec. seismicmaps.org <br /> Notes: <br /> A. Use the value provided unless the simplified design procedure of ASCE 7 Section 12.14 is <br /> used. If this occurs,please contact our office for more information. <br /> B. Based on Table 1613.2.3(2)of the 2018 IBC—An ASCE 7-16 Chapter 21 analysis has not been <br /> performed. <br /> C. More detailed seismic design criteria are available upon request. Please contact MGI's office <br /> for more information. <br /> 3.6 Liquefaction Potential <br /> Liquefaction is a sudden increase in pore water pressure and a sudden loss of soil shear strength <br /> caused by shear strains, as could result from an earthquake. Research has shown that saturated, <br /> loose,fine to medium sands with a fines(silt and clay)content less than about 20 percent are most <br /> susceptible to liquefaction. Our explorations did not encounter any extensive deposits of poorly <br /> consolidated sandy soil, and we do not anticipate that site soils will liquefy during a large-scale <br /> seismic event. <br /> Migizi Group,Inc. Page 6 of 16 <br /> rnwiz� It.4j <br />
The URL can be used to link to this page
Your browser does not support the video tag.