Laserfiche WebLink
19011 Wood-Sno Road NE,Suite 100 <br /> Woodinville,WA 98072-4436 <br /> Phone 425-814-8448 <br /> ENGINEERING Fax:425-821-2120 <br /> Pacific Ridge Homes Revision Date: 1/11/2021 <br /> Thelon (Elevations A & B) <br /> Criteria <br /> Code: toys 18C <br /> Allowable Stress Design(ASD) <br /> Seismic Design: ASCE 7-16: 12.8 Equivalent Lateral Force Procedure <br /> Wind Design: ASCE 7-16:Ch.28 Envelope Procedure, Low Rise <br /> Risk Category: I1-Other structures v Table 1.5-1 <br /> Snow Importance Factor is = 1.00 Table 1.5-2 <br /> Ice Importance Factor-Thickness l; = 1.00 Table 1.&2 <br /> Ice Importance Factor-Wind 1, = 1.00 Table 1.5-2 <br /> Seismic Importance Factor le = 1.00 Table 1.5-2 <br /> Spectral Response, Short Period Ss = 1.500 (Mapped) <br /> Spectral Response, 1-s Period S1 = 0.500 (Mapped) <br /> Site Class assumed,no Geotechnical Report v <br /> Site Class: D • Table 20.3-1 <br /> Site Coefficient F8 = 1.20 Table 11.4-1 <br /> Site Coefficient F„ = 1.80 Table 11.4-2 <br /> Structural Systems: <br /> Light framed walls with shear panels <br /> All other structural systems w i Tc = 6 (Figs. 22-14 tthru 22-17) <br /> Response Modification Coefficient R = 6.5 Table 12.2-1 <br /> Overstrength Factor Oo = 3 Table 12.24 <br /> Deflection Amplification Factor Cd = 4 Table 12.2-1 <br /> Basic Wind Speed:_ 100 mph - `• <br /> Exposure to Wind: Exposure s Section 25.7.3 <br /> Topographical Factor Kam= 1.00 <br /> Date:4/6/2022 <br /> Page: L1.1 <br />