Laserfiche WebLink
Structural Design Criteria <br /> Building Code: 2018 International Building Code <br /> Building Department: City of Everett <br /> Materials Criteria <br /> Structural Steel: <br /> Wide-Flange Sections: A-992 Fy= 50,000 PSI <br /> Snow Load Roof 25 psf <br /> Assembly Loads <br /> Roof (e)Gravit(n)Gravit Comments <br /> 3x Top Plate 0.6 psf 0.6 psf <br /> 1 1/2" B Deck 2.3 psf 2.3 psf <br /> 5/8"GWB 2.8 psf <br /> Steel Framing 6.7 psf 6.7 psf <br /> Mech./Elec. <br /> Acoustic Panels <br /> Sprinklers <br /> PV Panels <br /> Misc. 0.3 psf 0.5 psf <br /> Total: 10.0 psf 13.0 psf SL=25 psf <br /> Beam Load 5.7 psf <br /> Girder Load 10.1 psf <br /> Detlection Criteria <br /> Roof <br /> Live Load: L/180 <br /> Total Load: L/120 <br /> Quantum Consulting Engineers LLC Project: COE Service Building 3 Roof Date: 8/4/23 Job No: 23294.01 <br /> ` 1511 Third Avenue, Suite 323 Designer: JJS Sheet: 1 <br /> Seattle,WA 98101 Client: 2812 Architecture Checked By: <br />