My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3200 CEDAR ST PANAMA BLDG 2025-09-10
>
Address Records
>
CEDAR ST
>
3200
>
PANAMA BLDG
>
3200 CEDAR ST PANAMA BLDG 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 8:19:35 AM
Creation date
8/12/2025 2:12:04 PM
Metadata
Fields
Template:
Address Document
Street Name
CEDAR ST
Street Number
3200
Tenant Name
PANAMA BLDG
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Title: <br /> Engineer: <br /> Project ID: <br /> Project Descr: <br /> Steel Beam Project File:Everett Storage.ec6 <br /> LIC#:KW-06016450,Build:20.23.05.22 QUANTUM CONSULTING ENGINEERS (c)ENERCALC INC 1983-2023 <br /> DESCRIPTION: Girder <br /> CODE REFERENCES <br /> Calculations per AISC 360-16, IBC 2021,ASCE 7-16 <br /> Load Combination Set: IBC 2021 <br /> Material Properties <br /> Analysis Method toad Resistance Factor Design Fy:Steel Yield : 50.0 ksi <br /> Beam Bracing: Beam is Fully Braced against lateral-torsional buckling E:Modulus: 29,000.0 ksi <br /> Bending Axis: Major Axis Bending <br /> D(0.250 S 0.6250 D 0.250 S 0.6250 D 0.250 S(0.6250) <br /> I ' <br /> W21 x48 W21 x48 21 x48 <br /> Span=4.50 ft Span=50.0 ft Sran=4.50 ft <br /> Il f � <br /> Applied Loads Service loads entered.Load Factors will be applied for calculations. <br /> Beam self weight NOT internally calculated and added <br /> Load for Span Number 1 <br /> Uniform Load : D=0.010, S=0.0250 ksf, Tributary Width=25.0 ft, (Roof Load) <br /> Load for Span Number 2 <br /> Uniform Load : D=0.010, S=0.0250 ksf, Tributary Width=25.0 ft,(Roof Load) <br /> Load for Span Number 3 <br /> Uniform Load : D=0.010, S=0.0250 ksf, Tributary Width=25.0 ft,(Roof Load) <br /> DESIGN SUMMARY • <br /> Maximum Bending Stress Ratio = 0.988: 1 Maximum Shear Stress Ratio= 0.150 : 1 <br /> Section used for this span W21 x48 Section used for this span W21 x48 <br /> Mu:Applied 393.088 k-ft Vu:Applied 32.50 k <br /> Mn`Phi:Allowable 397.951 k-ft Vn" Phi:Allowable 216.30 k <br /> Load Combination +1.20D+1.60S Load Combination +1.20D+1.60S <br /> Location of maximum on span 4.500 ft <br /> Span#where maximum occurs Span#2 Span#where maximum occurs Span#1 <br /> Maximum Deflection <br /> Max Downward Transient Deflection 3.062 in Ratio= 195 - Span:3:S Only <br /> Max Upward Transient Deflection -0.864 in Ratio= 125 - Span:3:S Only <br /> Max Downward Total Deflection 4.297 in Ratio= 140 - Span:3:+D+S <br /> Max Upward Total Deflection -1.210 in Ratio= 89 - Span:3:+D+S <br /> Maximum Forces& Stresses for Load Combinations <br /> Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values <br /> Segment Length Span# M V max Mu+ max Mu- Mu Max Mnx Phi`Mnx Cb Rm VuMax Vnx Phi'Vnx <br /> +1.40D <br /> Dsgn. L= 4.50 ft 1 0.009 0.040 -3.54 3.54 442.17 397.95 1.00 1.00 8.75 216.30 216.30 <br /> Dsgn.L= 50.00 ft 2 0.266 0.040 105.83 -3.54 105.83 442.17 397.95 1.00 1.00 8.75 216.30 216.30 <br /> Dsgn.L= 4.50 ft 3 0.009 0.007 -3.54 3.54 442.17 397.95 1.00 1.00 1.57 216.30 216.30 <br /> +1.20D <br /> Dsgn.L= 4.50 ft 1 0.008 0.035 -3.04 3.04 442.17 397.95 1.00 1.00 7.50 216.30 216.30 <br /> Dsgn.L= 50.00 ft 2 0.228 0.035 90.71 -3.04 90.71 442.17 397.95 1.00 1.00 7.50 216.30 216.30 <br /> Dsgn.L= 4.50 ft 3 0.008 0.006 -3.04 3.04 442.17 397.95 1.00 1.00 1.35 216.30 216.30 <br /> +1.20D+0.50S <br /> Dsgn. L= 4.50 ft 1 0,016 0.071 -6.20 6.20 442.17 397.95 1.00 1.00 15.31 216.30 216.30 <br /> Dsgn. L= 50.00 ft 2 0.465 0.071 185.20 -6.20 185.20 442.17 397.95 1.00 1.00 15.31 216.30 216.30 <br /> Dsgn. L= 4.50 ft 3 0.016 0.013 -6.20 6.20 442.17 397.95 1.00 1.00 2.76 216.30 216.30 <br /> +1.20D+1.60S <br /> Dsgn. L= 4.50 ft 1 0.033 0.150 -13.16 13.16 442.17 397.95 1.00 1.00 32.50 216.30 216.30 <br />
The URL can be used to link to this page
Your browser does not support the video tag.