Laserfiche WebLink
TO ETHERNET PM <br /> FOR 5.31 FOR 5.31 CONNECTION <br /> FDR 6-31 FOR 6-31 <br /> LEGEND <br /> SEE LEGEND SHEET 40-058-EO&40-058-El FOR <br /> r-- ------------ ------------------------------------------ ------------------------------------ ABBREVIATIONS,&NOTES. <br /> I I <br /> � ETHERNET <br /> S CONNECTIVITY <br /> FOR PM <br /> SUBSTATION 31-2 (V58-1A) �� GENERAL NOTES <br /> G2 2 6 1 NOT USED <br /> 1200 AMP,3 POLE,61KA 480Y/277V 30 4W 3200A <br /> G1 Gi AIR INTERRUPTER LOAD D1 <br /> BREAKER SWITCH 85 KA I C <br /> 1 <br /> 100E <br /> 1 G2 0 15001AA/2000FA KVA <br /> CONSTRUCTION NOTES <br /> 12.47KV-480Y/277V <br /> 1 3PH,4W Z=5.75% a " FURNISH AND INSTALL 1600 AMP EATON DIGITRIP 1150+LSIG ELECTRONIC TRIP <br /> UNIT IN EXISTING SPARE 1600 AMP BREAKER FRAME IN CUBICLE AS. <br /> z D` CONTRACTOR SHALL WORK WITH SIEMENS REPRESENTATIVE TO DETERMINE <br /> a PROPER SETTINGS FOR BREAKER COORDINATION. <br /> 1 a FURNISH AND INSTALL NEW CONDUIT AND CONDUCTORS.ROUTE CONDUIT FROM <br /> 3200AF T �� m 4V -1A A.4- CUBICLEAR L.AND TERMINATE AT THE 1200A <br /> 2500AT 0\ ^ CPT D IST IB 10 PA E <br /> MAIN SKVA w <br /> _ 480V-240/120V w FURNISH AND INSTALL 48OV,3P,4W,1200A 65KAIC,NEMA 12,DISTRIBUTION <br /> PANEL.PANEL VENDOR:IEM OR APPROVED EQUAL. <br /> w <br /> 2400:5 B PM AS A 0-2400 N FURNISH AND INSTALL METERING EQUIPMENT AS PER DRAWING SHEET <br /> M.R. (4) z E814-03-09.METERING PART NO.LEVITON SERIES 4000-R OR APPROVED EQU <br /> A,B,C,N ) <br /> S R BUTION <br /> FURNISH <br /> INSTALL <br /> PANEL.IEM CATALOG NUMBER: <br /> 30,4-WIRE,35KAIC <br /> D <br /> 1 CPT TRANSFER D1 ASB-PIU-225MLO-4803P4W42CKT-N12 OR APPROVED EQUAL. <br /> SCHEME� — — <br /> B VS V 240/120V ©FURNISH AND INSTALL 100A BUS,100A MAIN CIRCUIT BREAKER,208Y/12OV,30, <br /> UNIT SUBSTATION TIE 4-WIRE,1 OKAIC,DISTRIBUTION PANEL.IEM CATALOG NO.: <br /> (3)PTS CONTROL POWER (NI y ASB-PIU-100AMCB-208V3P4W42CKT-N12 OR APPROVED EQUAL. <br /> 277-120V Q 7�FURNISH AND INSTALL 30KVA,48OV-208Y/12OV,3-PHASE DRY TYPE <br /> Al A2 A3 A4 A5 A6 A7 A8 A9 E-o �� TRANSFORMER.IEM CATALOG NUMBER:ASB-9T10C1002G34,OR APPROVED <br /> 1 EQUAL. <br /> 3200AF I <br /> m 00AT 8 FURNISH AND INSTALL COPPER GROUND BUS BAR. <br /> 1 a` SPACE SPACE a a SPACE a a b FURNISH ARC FLASH REDUCTION MAINTENANCE SWITCH AS PER NEC 240.87 <br /> / 1806 OAT / i600ATF / i800AT / i800ATF / 800AT / 1200AT <br /> 10 REFER TO DRAWING#1E111-14 FOR HAZARDOUS CLASSIFIED AREAS FOR <br /> CONDUIT&CABLE INSTALLATION REQUIREMENTS <br /> L-------------- ----------------------------- -------------------------- --------- ----------- --- ------ -----------------------� <br /> REFERENCE DRAWINGS <br /> at u is is SPARE CD <br /> Y Y Z Y Z Y U <br /> o w o w <br /> o z SUBSTATION 31-2(V58-1A)/31-1(V58-16)LOAD SUMMARY <br /> M w <br /> a EXISTING ELECTRICAL LOAD=261+34= 295 AMPS ` <br /> S2N SQN SQN 59 D1 <br /> N w NEW CONNECTED LOAD=964+1034= 1998 AMPS <br /> V <br /> TOTAL CONNECTED ELECTRICAL LOAD= 2293 AMPS <br /> D (4)SETS:(4)#400KCMIL,#3/0 G <br /> EFR PAINT BOOTH 2. EA.SET IN 3"C r-- ---------- <br /> ----------- <br /> ----� <br /> REFERENCE PARIDURR <br /> D CU N TI S T. 1 )1200A GFR <br /> -------------- ----------- —————————————— ————————————— ——————————————— --J <br /> 3V58-1AB4.0-D 3V58-1AC4.0-D 3V58-1APB4.0-D <br /> I I I 1 3V58-1AMA3.75D <br /> 480V 30,4W 480V 3H,4W 480V 3Q1,4W <br /> D 1 800A MLO I 800A ML I 800A MLO I I 800A MLO 1 480V 3Ph,4W,1200A <br /> 1 65 kAIC I 480V 1 65 kAIC 1 1 65 kAIC 65 kAIC,NEMA 12 <br /> I I 30,3W I I <br /> I V58-1APB4.0 I <br /> I 65 kAIC I <br /> 1 >150A )400A )50A )225A )225A )SOA )225A )150A )400A I >100A )50A )50A )40A )90A )200A )200A )200A )200A >125A )60A )50A D 1 <br /> I I <br /> L--- ---- ----- ------- ----- --- -- ---- ------i L----------- -----J L----- ----- ----- ----- ----- ---- <br /> U U U U SPARE # # U SPARE <br /> �ipE U O (V c�pk <br /> # N # 5 V M th M N # N # N N M 19 <br /> C7 <br /> M <br /> 225A MLO J <br /> N U 60 480Y/277V `U BOOTH 2 BOOTH 2 BOOTH 2 BOOTH 2 BOOTH 2 BOOTH 2 LIFTING BOOTH 2 <br /> Y 60/3 <br /> 3E c NF 225A MLO 225A MLO NF 30,4W o NF APPLICATION ASH 1 ASH 1 SUPPLY ASH 1 EXHAUST ASH 1 SUPPLY ASH 1 EXHAUST SYSTEM 92& SPAR CART <br /> 480V 480V 3V58-1AMA4.0-1 MCP1 FAN 1 FAN 1 FAN 2 FAN 2 SUPERVISORY POWER <br /> 35 ONIC <br /> EQUIPMENT#2 <br /> 3V58-1AA3.65 3V58-1AB4.0-1 U <br /> Q T-2V58-1A64.0-2 <br /> 35 kAIC 35 kAIC # 30KVA <br /> 0 T-2V58-1AA3.65 Q T-2V58-1AB4.0-1 �� `T-2V58-1AMA4.0 480:208Y/120V <br /> 30KVA 30KVA 30KVA <br /> 480:208YI120V 480:208Y/120V 480:208Y/120V <br /> V V V <br /> _ M _ ECN 001 <br /> SPAR SPAR SPAR SPAR <br /> T&D#1 T&D#1 T&D#2 T&D#2 <br /> NCMF ELECTRICAL NCMF ELECTRICAL -� <br /> CABINET CABINET CABINET CABINET <br /> AVAILABLE AVAILABLE AVAILABLE AVAILABLE HARRIS GROUP <br /> FAULT FAULT 100A MCB 100A MCB 100A MCB FAULT FAULT 100A MLO 100A MCB J REVISION'Di"ONLY <br /> CURRENT: CURRENT: 208Y/120V 208Y/120V 208Y/120V CURRENT: CURRENT: 480Y/277V 208Y/120V J PROJECT NO:0012630.06 <br /> 25KA 25KA 30,4W 30,4W 30,4W 25KA 25KA 30,4W (METERED PANEL) 30,4W <br /> 2V58-1AA3.65 2V58-1AB4.0-1 2V58-1AMA4.0 3V58-1AB4.0 2V58-1AB4.0-2 EEL <br /> PROJMGR: RLT <br /> 10 ONIC 10 kAIC 10 kAIC LIGHTING 10 kAIC <br /> 65 kAIC APPROVED: RLT <br /> DATE: 01.27.23 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTRLE CURRENT REVISION SYMBOL DATE <br /> ¢�30HIYd ACCEPTABILITY RER 12105114 W5983281 D1 012723 <br /> A 777X CWC NEW BUILDING-RECORD WBS 2548317 JMG DFC 01103117 C,,�P'Oy WAsyr'1c+��' SPECIFICATION AJ PI ROVED RFW CHECKED 12ro5114 SUB 31-2(V58-1A)ONE-LINE DIAGRAM SHEET <br /> ¢ T'A ENGINEER TITLE E41A <br /> B 777XCWC NEW BUILDING-RECORD WBS2548317 JMG DFC 07105117 ® z APPROVEOBY oEPr. oArE DFC 2ro514 PFP SPAR PAINT BOOTH1AND2PHASE2 <br /> BOE/A/G CHECKED <br /> C PFP SPAR PAINT BOOTH 1 AND 2 PHASE 1-RECORD W5983281 HG RLT XX.XX.XX /'� C 0 <br /> � <br /> D PFP SPAR PAINT BOOTH 1 AND 2 PHASE 2-IFC W5983281 HG RLT 06.03.22 A�0 lEC STES4F'q{A�� APPROVED BUILDING 40-058 NO. COMP NO. <br /> D1 PFP SPAR PAINT BOOTH 1 AND 2 PHASE 2-ECK001 W5983281 HG RLT 01,27.23 �SS70NA, APPROVED ELECTRICAL MASTER EVERETT,WA DWG NO 40-058-E4-1A <br />