My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-58 2025-09-29
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
3003 W CASINO RD BLDG 40-58 2025-09-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 9:12:25 AM
Creation date
8/12/2025 3:19:33 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
2022
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Seismic Bracing <br /> . ..... .........._........_............_ <br /> TOWOT' Fig. 1001 - Sway Brace Attachment (UL Listed) <br /> Size Range: Pipe size to be braced: 1'(25mm)thru 8"(200mm)IPS. QPM C V� US <br /> Pipe size used for bracing: 1'(25mm)and 11/4'(32mm)Schedule 40 IPS. <br /> Material: Steel LISTED <br /> Function: For bracing pipe against sway and seismic disturbance. <br /> The pipe attachment component of a sway brace system: <br /> Fig. 1001 is used in conjunction with a Fig.900 Series fitting and <br /> joined together with bracing pipe per NFPA 13, forming a complete <br /> sway brace assembly. <br /> Features: Can be used to brace schedule 7 through schedule 40 IPS. <br /> Field adjustable, making critical pre-engineering of bracing pipe <br /> length unnecessary. Unique design requires no threading of bracing <br /> pipe.Comes assembled and ready for installation. Fig. 1001 has built-in <br /> visual verification of correct installation.See installation note below. <br /> Installation Note: Position Fig. 1001 over the pipe to be braced Set Betts <br /> and tighten two hex head cone point set bolts until heads bottom Included <br /> out.A minimum of 1'(25mm)pipe extension is recommended. Brace pipe <br /> can be installed on top or bottom of pipe to be braced. <br /> Approvals: Underwriters Laboratories Listed in the USA(UL) <br /> OWN It <br /> r <br /> and Canada(cUL). Included in our Seismic Engineering Guidelines approved r;F <br /> by the State of California Office of Statewide Health Planning and <br /> Development(OSHPD). For additional load, spacing and placement <br /> information relating to OSHPD projects, please refer to our Seismic <br /> Engineering Guidelines, OPM-0062-13. i <br /> For FM Approval information refer to FM Approved page 67. ki <br /> Finish: Plain or Electro-Galvanized. Contact customer service for alternative <br /> finishes and materials. <br /> Order By: Order by figure number, pipe size to be braced,followed by pipe <br /> size used for bracing (1"(25mm)or 1 t/4"132mm)),and finish. <br /> Important Note: Fig. 1001 is precision manufactured to perform its <br /> function as a critical component of a complete bracing assembly.To ensure <br /> performance,the UL Listing requires that Fig. 1001 must be used only with <br /> other TOLCO bracing products. <br /> Pipe Part Numher&Approx.Wt:/100 Design Load-Lbs. <br /> Size 1"(24mm)Brace Pipe 11/4"(32=0 Brace Pipe For Brace Pipe Size 1" <br /> Sch.7 Sch.10 Sch.40 <br /> in. (min) Lbs. (kg) Lbs, (kgl 1"/11/4" 1"111/4" 1"/11/4" <br /> t 3 <br /> 1".. [25} 1001-1:X 1 .::..:'.100.0 145 3) 1001-1 X 1/4 118A 153.5)....r . .... ./... .......1000/1000 1000/1000 <br /> 1 1/4"(321 1001-11/4 X 1 100.0 (45.31 1001-11/4 X 11/4 114.0 (51.7) 1000/1000 1000/1000 1000/1000 <br /> ;1 112":[40}. '. i'1001-1t/2.X.1 100.0 i45.3):;: `':1001-112X1�4.:;::115, 52.1 : 1000 1000 '::::::1500 1500': !;::1500 15 <br /> 2" (50) 1001-2 X 1 108.0 (49.0) 1001-2 X 11/4 121.0 (54.81 1000/1000 2015/2015 2015/2015 <br /> 2t/z fs5) : 1001-2t/2 X 1 138.6.:01) .. . . 1001:2�/z X 1 J4: .. 160.4 i72 7) ? 9600 J 1600 ::::2015/2765 .. ::2015/.2765 <br /> 3" (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 1600/1600 2015/2765 2015/2765 <br /> .10t11-.9X1 160,9 :[73.0): : : 1001-.4X.1,A. i82.4..(82.7}. : 16�):16fHi 2015J2765.: 2015/2165 <br /> 6" (150) 1001-6 X 1 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 1600/1600 2015/2765 2015/2765 <br /> 8". (200 ;:I .1001-8 X 1 217.4 98.6 '1001-8 X 114. . . `238.8 108.3 :: '.1 1 2 2] ; ....... { ) / .. [ 1 I 6001. 600 015/ 765 2015/2765 <br /> Note: Metric sizes are available, contact factory. <br /> - Fig.1001 -- -- <br /> L <br /> All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> .............................._........... ...._............ _._...._..__......_._..................... . . . -.................... ........_....._.......... <br /> _.........._..._......... <br /> Eaton 66 B-Line series Fire Protection Solutions <br />