My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-58 2025-09-29
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
3003 W CASINO RD BLDG 40-58 2025-09-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 9:12:25 AM
Creation date
8/12/2025 3:19:33 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
2022
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Seismic Bracing <br /> TOLCOT" Fig. 828 - Universal Sway Brace Attachment to Steel (FM Approved) <br /> Size Range: One size accommodates all sway Fig.900 Series brace OPM �M <br /> Y <br /> I 3 7 O <br /> attachments. Fits from /8" 19.4mm)to /8" (22.2mm)thick steel structure. For thicknesses APPROVED <br /> less than 3/8" (9.4mm)refer to Fig.825. <br /> j Material: Steel cone Point <br /> Function: To attach sway bracing and/or hangers to various types of steel structural 4colie <br /> et Bolts A <br /> members.Features: Permits secure non-friction connection without drilling or welding. Uniquesot sops <br /> design allows offset placement on wide flange beam, I-beam,C-channel,open web, Included <br /> welded steel trusses, etc.. Secures brace to structure either across or along the beam. <br /> Break-off set bolts allow for visual verification of proper installation torque. <br /> Approvals: Factory Mutual Approved(FM). Included in our Seismic Engineering <br /> Guidelines approved by the State of California Office of Statewide Health Planning and <br /> Development(OSHPD). For additional load, spacing and placement information relating to Point <br /> OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. Set Bolt B <br /> For UL Listed information refer to UL Listed page 52, <br /> Installation Instructions: The Fig.828 is the structural attachment component of a <br /> longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO <br /> transitional attachment,'bracing pipe"and a TOLCO'braced pipe'attachment to form a <br /> complete bracing assembly. NFPA 13 or FM guidelines should be followed. <br /> To Install: Place the Fig.828 on the flange of the beam,truss, or girder. Be sure the <br /> attachment is fully engaged to the rear of the opening.Tighten the cone point set bolts(A) <br /> until the heads break off.Tighten the cone point set bolt 113)until the head breaks off. r <br /> Remove the flange nut from set bolt(B). Install a TOLCO swivel fitting Fig.980 or any <br /> other TOLCO approved transitional fitting). 1 <br /> Use flange nut to secure the swivel fitting'. <br /> Finish: Plain or Electro-Galvanized <br /> Approx.Weight/100: 275 Lbs. (124.7ky) F '.Order By: Figure number and finish <br /> Patent tf6,098,942,#8,534,625 <br /> Canada Patent#2,286,659 <br /> Patent Pending <br /> Designed to meet or exceed requirements of FM DS 2-8. <br /> ' Retaining strap not required. <br /> FM Approved Allowable Horizontal Load* -----.-----, ______________ <br /> With Brace Perpendicular To Beam 1 ! <br /> Brace Angle degrees front vertical) <br /> 30'-44° y 450-590 60°-74° 75*-900 <br /> ..........___ _............................._._.........._...._._._.._.__.... ..... Fig.828 ; <br /> 1570 2220 1210 700 y t__ }_________ ... <br /> (8.98kN1 JUAN) 15.38kN) (3.11kN) <br /> e Fig.828 <br /> Shown with - May pivot in any <br /> FM Approved Allowable Horizontal Load' Fig 3B0 direction <br /> With Brace Parallel To Beam shown with <br /> Brace Angle Idegrees from vertical) Fig.980 <br /> 30'-44° 45°-59* 600-740 75°-90° <br /> ...................................... .. ................................................. <br /> 690 970 1210 1330 <br /> (3.07kN) (4.3lkN) (5.38kN) (5.9lkN1 <br /> FM Approved design loads are based on ASD <br /> design method. <br /> Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, <br /> resulting in a listed seismic bracing assembly.Eaton B-Line Division warranty for seismic bracing components will be the warranty <br /> provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton,except that,in addition to the other <br /> exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are <br /> combined with products not provided by Eaton. <br /> Al dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> . <br /> ................_.............. . ........_.._................._._._.......... <br /> B-Line series Fire Protection Solutions 53 Eaton <br />
The URL can be used to link to this page
Your browser does not support the video tag.