My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-58 2025-09-29
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
3003 W CASINO RD BLDG 40-58 2025-09-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 9:12:25 AM
Creation date
8/12/2025 3:19:33 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
2022
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> 4 Page 2 of 7 <br /> l <br /> k <br /> MAP 714 <br /> EASY RISER® SWING <br /> • • A 4 CHECK VALVE <br /> N41K1W4J <br /> f <br /> MODELS E-1 & F-1 <br /> f <br /> i <br /> f <br /> f The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp.com <br /> i Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com <br />( 4. INSTALLATION <br /> I The Easy Risers Swing Check Valve must be installed in an area not subject to freezing temperatures or physical damage. When <br /> corrosive atmospheres and/or contaminated water supplies are present, it is the owner's responsibility to verify compatibility with the <br /> Easy Riser's Swing Check Valve, trim, and associated equipment. <br /> Prior to installing the valve, thoroughly flush the water supply piping to verify that no foreign matter is present. <br /> The Easy Riser's Swing Check Valve may be installed in the vertical position with direction of flow up, or in the horizontal position <br /> E with the access cover up. <br /> 1. Remove all plastic thread protectors from the openings of the Easy Riser'a Swing Check Valve. <br /> 2.Apply a small amount of pipe-joint compound or tape to the external threads of all pipe connections required.Take care not to allow <br /> r any compound, tape, or other foreign matter inside any of the nipples or openings of the valve or trim components. <br /> 3. Easy Riser"Swing Check Valve Trim Charts are provided with Trim Packages and on the Viking websile. <br />€ 4. Verify that all system components are rated for the water working pressure of the system. <br /> f Hydrostatic Test: <br /> The Easy Riser`s Swing Check Valve is manufactured and listed for use at a maximum water working pressure of 300 psi (20.7 bar). <br /> The valve is factory tested at 600 psi(41.4 bar). Easy Riser's Swing Check Valves may be hydrostatically tested at 350 psi(24.1 bar) <br /> and/or 50 psi(3.5 bar)above the normal water working pressure for limited periods of time(two hours)for the purpose of acceptance <br /> by the Authority Having Jurisdiction. If air testing is required, DO NOT exceed 40 psi (2.8 bar) air pressure. <br /> 5. OPERATION (Refer to Figure 1.) <br /> Water flowing through the Viking Easy Riser® Swing Check Valve lifts the rubber-gasketed clapper (8 and 9) off the seat (12) and <br /> flows into the sprinkler piping. When flow through the valve stops, the clapper(8)closes quickly.The rubber gasket (9)forms a tight <br /> seat against the brass water seat(12), trapping pressurized water above the clapper and preventing reverse flow from the sprinkler <br /> piping. <br /> 6. INSPECTIONS, TESTS, AND MAINTENANCE <br /> 0 <br /> The owner is responsible for maintaining the fire protection system and devices in proper operating condition. <br /> The Viking Easy Risers Swing Check Valve and trim must be kept free of foreign matter,freezing conditions, corrosive atmospheres, <br /> contaminated water supplies, and any condition that could impair its operation or damage the device. <br /> It is imperative that the system be inspected and tested on a regular basis. The frequency of the inspections may vary due to con- <br /> taminated water supplies, corrosive water supplies, and corrosive atmospheres. For minimum maintenance and inspection require- <br /> ments, refer to NFPA 25. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection <br /> requirements that must be followed. <br /> Any system maintenance that involves placing a control valve or detection system out of service may eliminate the <br /> fire protection capabilities of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration <br /> should be given to employment of a fire patrol in the affected areas. <br /> 6-A. Five-Year Internal Inspection <br /> Internal inspection of check valves is recommended every five years unless inspections and tests indicate more frequent inspec- <br /> tions are required. (Refer to Figure 1.) <br /> 1. Notify the Authority Having Jurisdiction, remote station alarm monitors, and those in the area affected that the systern will be <br /> taken out of service. Consideration should be given to employment of a fire patrol in the affected areas. <br /> 2. Close the water supply main control valve, placing the system out of service. <br /> 3. Open the main drain. If necessary, open the systern test valve to vent and completely drain the system. <br /> 4. Use the appropriate wrench to loosen and remove cover screws (14), and remove cover and clapper assembly (2-11). <br /> 5. Inspect water seat(12). Wipe away all contaminants, dirt, and mineral deposits. DO NOT use solvents or abrasives. <br /> 6. Inspect cover and clapper assembly (2-11) and cover gasket (13). Test the hinged clapper (8) for freedom of movement. <br /> Renew or replace damaged or worn parts as required, <br /> Form No. F_011189 18.10.11 Rev 18,1.P65 <br />
The URL can be used to link to this page
Your browser does not support the video tag.