My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7814 E CASINO RD 2025-09-10
>
Address Records
>
E CASINO RD
>
7814
>
7814 E CASINO RD 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 8:00:03 AM
Creation date
8/12/2025 3:46:07 PM
Metadata
Fields
Template:
Address Document
Street Name
E CASINO RD
Street Number
7814
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL YES NO <br /> Bathroom doors are easily and quickly openable from the outside when locked 13 <br /> Carbon Monoxide alarms are installed as required in R315 on each level of the home. ❑ <br /> Smoke alarms are installed on all levels of the dwelling,in each resident sleeping room,outside each separate <br /> sleeping area in the immediate vicinity of sleeping rooms(11314). <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all IR ❑ <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requirements. ❑ <br /> R330.4 Operable parts of door handles,pulls, latches,locks and other devices installed in AEH shall be operable <br /> with one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 69 <br /> Pocket doors shall have graspable hardware available when in the closed or open position. <br /> R311.8 Ramp <br /> YES NO <br /> inside Ramp I N/AJW ❑ ❑ <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope). (Exception R311.8,1 Not allowed in j ❑ ❑ <br /> R330.9) <br /> R311.8.2 landing Requirements: min.3X3 foot landing at top/bottom,where doors open onto ramps,and where <br /> ramp changes directions. ❑ ❑ <br /> R330.9.1 Handrails required on both sides of ramp. ❑ 1 13 <br /> Outside Ramp I N/A© - YES NO <br /> Wr <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311,8,1 Not allowed in [3 <br /> R330.9) <br /> R311.8.2 landing Requirements: min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ❑ <br /> ramp changes directions. <br /> R330.9.1 Handrails required on both sides of ramp. ❑ <br /> R312.1.1 Guards shall be located along open-sided walking surfaces,that are located more than 30 inches measured ❑ <br /> vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. <br /> Guards below are depicted vertically as an example only. <br /> Handrail both sides <br /> Less than 4" ' 34"-38" <br /> Guard <br /> 36"mitt <br /> 3'x3'min <br /> a II 'i ' i I I I, !: I ! I` I landing <br /> ' l Tx 3'min � --�:-�-, I I '• I -- <br /> landing -_- --- <br /> -3' -One unit vertical in twelve units horizontal 3' ---j <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> Implementation Date: 2021 February 01 <br /> Updated: 2021 February <br />
The URL can be used to link to this page
Your browser does not support the video tag.