, , <br /> BirL, 19011 Wood-Sno Road NE,Suite 100 <br /> Woodinville,WA 98072-4436 <br /> Phone:425-814-8448 <br /> E NGINEERIN G Fax:425-821-2120 <br /> Sage Homes Revision Date: 1/11/2021 <br /> Harbors Edge TH-4-Plex(Units 6-9) <br /> Ps=A KZT PS30 (28.5-1) Exposure= C <br /> A= 1.39 (Fig.28.5.1) Mean Roof Ht hn(ft)= 30 ft <br /> Kn= 1.00 (Section 26.8) a(root)= 4.0 ft <br /> a(upper/main floor)= 3.9 ft <br /> Basic Wind Speed= 100 mph <br /> Roof Angle= 15 <br /> North/South Loading 28.5.4 Minimum Design Loads <br /> Zone Area P.a(Psi) Psmdnr.,(Psi) P(Psi) Force(8) ASD Force(6) Force(6) AS0 Force(6) <br /> Root km 32 19.9 19.9 27.7 885 531 512 307 <br /> Agable 20 19.9 19.9 27.7 553 332 320 192 <br /> B 40 -6.6 0.0 0.0 0 0 320 192 <br /> Cwall 280 13.3 13.3 18.5 5176 3106 4480 2688 <br /> Cgable 96 13.3 13.3 18.5 1775 1065 1536 922 <br /> D 200 -3.8 0.0 0.0 0 0 1600 960 <br /> Total Area= 668 Total Load= 8389 5034 8768 5261 <br /> Design: 8768 5261 <br /> Zone Area P.m(Psi) P,, ,,_(Psi) P(psi) Force(4) ASD Force(6) Force(4) ASD Force(4) <br /> Floor 3 Awall 75 19.9 19.9 27.7 2072 1243 1198 719 <br /> Agable 0 19.9 19.9 27.7 0 0 0 0 <br /> B 0 -6.6 0.0 0.0 0 0 0 0 <br /> Cwall 666 13.3 13.3 18.5 12314 7389 10658 6395 <br /> Cgable 0 13.3 13.3 18.5 0 0 0 0 <br /> D 0 -3.8 0.0 0.0 0 0 0 0 <br /> Total Area= 741 Total Load= 14386 8632 11856 7114 <br /> Design: 14386 8632 <br /> Zone Area P sm(pat) P sud.nm(Psi) P(Ps0 Force(6) ASD Force(4) Force(4) ASD Force(A) <br /> Floor2 Awall 74 19.9 19.9 27.7 2050 1230 1186 711 <br /> Agable 0 19.9 19.9 27.7 0 0 0 0 <br /> B 0 -8.6 0.0 0.0 0 0 0 0 <br /> Cwall 667 13.3 13.3 18.5 12329 7397 10670 6402 <br /> Cgable 0 13.3 13.3 18.5 0 0 0 0 <br /> D 0 -3.8 0.0 0.0 0 0 0 0 <br /> Total Area= 741 Total Load= 14379 8627 11856 7114 <br /> Design: 14379 8627 <br /> EasWVest Loading 28.5.4 Minimum Design Loads <br /> Zone Area P sm(Psi P smd..,w(Psi) P(Psi) Force(4) ASD Force(6) Force(4) ASO Force(8) <br /> Roof Awall 32 19.9 19.9 27.7 885 531 512 307 <br /> Agable 0 19.9 19.9 27.7 0 0 0 0 <br /> B 40 -6.6 0.0 0.0 0 0 320 192 <br /> Cwall 128 13.3 13.3 18.5 2366 1420 2048 1229 <br /> Cgable 0 13.3 13.3 18.5 0 0 0 0 <br /> D 160 -3.8 0.0 0.0 0 0 1280 768 <br /> Total Area= 360 Total Load= 3251 1951 4160 2496 <br /> Design: 4160 2496 <br /> Zone Area P.,(Psi) P<md.,r.(Psi) P(Psf) Force(8) ASD Force(4) Force(4) ASO Force(8) <br /> Floor3 Awall 71 19.9 19.9 27.7 1964 1178 1136 682 <br /> Agable 0 19.9 19.9 27.7 0 0 0 0 <br /> B 0 -6.6 0.0 0.0 0 0 0 0 <br /> Cwall 309 13.3 13.3 18.5 5712 3427 4944 2966 <br /> Cgable 0 13.3 13.3 18.5 0 0 0 0 <br /> D 0 -3.8 0.0 0.0 0 0 0 0 <br /> Total Area= 380 Total Load= 7676 4606 6080 3648 <br /> Design: 7676 4606 <br /> Zone Area Ps.(Psi) p wank.(psi) p(psf) Force(8) ASD Force(4) Force(6) ASD Force(4) <br /> Floor 2 Awall 74 19.9 19.9 27.7 2050 1230 1186 711 <br /> Agable 0 19.9 19.9 27.7 0 0 0 0 <br /> B 0 -6.6 0.0 0.0 0 0 0 0 <br /> Cwall 302 13.3 13.3 18.5 5581 3349 4830 2898 <br /> Cgable 0 13.3 13.3 18.5 0 0 0 0 <br /> D 0 -3.8 0.0 0.0 0 0 0 0 <br /> Total Area= 376 Total Load= 7631 4579 6016 3610 <br /> Design: 7631 4579 <br /> Date:5/16/2023 <br /> Page: L1.4 <br />