4 of 34 <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 4 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.2 Bond Strength <br /> Nag =(AANaNO) W ec1,Na Wec2,Na Wed,Na Wcp,Na Nba ACI 318-14 Eq.(17.4.5.1b) <br /> Nay >N. ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANaO =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> cNa =10 da V 100uncr ACI 318-14 Eq.(17.4.5.1 d) <br /> 1 <br /> Wec,Na = \1 eN/ <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> CNa <br /> W ed,Na =0.7+0.3(ca=min) 1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> CNa <br /> W cpNa =MAX(Ca—min,cta) <1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> Cac Cac <br /> Nba =X a•tk,c• •da•het ACI 318-14 Eq.(17.4.5.2) <br /> Variables <br /> k,c,uncr[psi] da[in.] hef[in.] c [in. tl(c si <br /> a,min ] aoverhead [p ] <br /> 2,327 0.500 4.000 1.000 1,190 <br /> ec1,N[in.] eo,N[in.] cad[in.] 2L a <br /> 0.000 0.000 10.058 1.000 <br /> Calculations <br /> CNa[in.] ANa[in 2] ANao[In.2] W ed,Na <br /> 7.239 245.82 209.62 1.000 <br /> W ec1,Na Wec2,Na Wcp,Na Nba[Ib] <br /> 1.000 1.000 1.000 7,475 <br /> Results <br /> Nag[Ib] 4)bond 4 Nag[Ib] N.[lb] <br /> 8,765 0.650 5,697 1,745 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 4 <br /> ., <br />