Laserfiche WebLink
7 of 34 <br /> I�11`TI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 7 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 4.2 Pryout Strength(Bond Strength controls) <br /> Vcpg =kcp[(ANa> W ec1,Na Wec2,Na Wed,Na Wcp,Na Nba , ACI 318-14 Eq.(17.5.3.1b) <br /> ANaO <br /> + Vcpg >Vua ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANag =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> CNa =10 do `1100 ACI 318-14 Eq.(17.4.5.1d) <br /> 1 <br /> Wec Na = \1 eN <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> CNa <br /> W ed,Na =0.7+0.3 (Ca=min)J <1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> CNa <br /> W Cac cP,Na =MAX(Ca=min, C cNa) <1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> ac <br /> Nba =X a't k,c'it'da•hef ACI 318-14 Eq.(17.4.5.2) <br /> Variables 1 <br /> kcp Goverhead tk,c,uncr[psi]1 da[In.] het[in.] ca,min[in.] t k,c[psi7 <br /> 2 1.000 2,327 0.500 4.000 00 1,190 <br /> ec1,N[in.] ecz,N[in.] cac[in.] X a <br /> 0.000 0.000 10.058 1.000 <br /> Calculations <br /> CNa[in.] ANa[in?] ANao[ln 2] W ed,Na <br /> 7.239 364.67 209.62 1.000 <br /> W ec1,Na Wec2,Na Wcp,Na Nba[Ib] <br /> 1.000 1.000 1.000 7,475 <br /> Results <br /> Vcpg[lb] concrete 4t Vcpq[Ib] Vua[lb] <br /> 26,006 0.700 18,204 314 <br /> 5 Combined tension and shear loads <br /> RN RV Utilization 140,[%] Status <br /> R 0.306 0.024 5/3 15 OK <br /> RNV=RN+ V<=1 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 7 <br /> r/ •• <br />