My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE BASE FILE 2025-09-29
>
Address Records
>
PACIFIC AVE
>
916
>
BASE FILE
>
916 PACIFIC AVE BASE FILE 2025-09-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 1:42:29 PM
Creation date
8/18/2025 9:28:15 AM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications <br /> Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for <br /> Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The <br /> detector shall be rated for activation at either 135°F(57°C)or 194°F(90oC),and shall activate by means of a fixed temperature thermal sensor, <br /> or a combination fixed temperature/rate-of-rise thermal sensor.The rate-of-rise element shall be activated by a rapid rise in temperature, <br /> approximately 15°F(8.3°C)per minute.The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch <br /> octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of <br /> SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to <br /> identify its temperature rating and activation method.The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be <br /> restorable,to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. <br /> Physical/Operating <br /> Maximum Installation Temperature 5601 P,5603,5621,and 5623: 100°F(38°C) <br /> 5602,5604,5622,and 5624: 150OF(65.6°C) <br /> Operating Humidity Range 5 to 95%RH non-condensing <br /> Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) <br /> Height: 1.69 inches(4.3cm) <br /> Alarm Temperature 5601 P,5603,5621,and 5623: 135°F(57°C) <br /> 5602,5604,5622,and 5624: 194OF(90°C) <br /> Weight 6 oz.(170 grams) <br /> Rate-of-Rise Threshold 150F(8.3°C)rise per minute(models 5601 P,5602,5621,and 5622 only) <br /> Mounting 31/2-inch octagonal back box <br /> 4-inch octagonal back box <br /> Single gang back box <br /> 4-inch square back box with a square to round plaster ring <br /> Electrical Specifications <br /> Operating Voltage/Contact 6-125VAC/3A <br /> Ratings 6-28VDC/1 A <br /> 125VDC/0.3A <br /> 250VDC/0.1A <br /> Input Terminals 14-22 AWG <br /> e "yd <br /> O O O O O <br /> a o o c o 0 0 0 <br /> 5601 P 5602,5622 5603,5623 5604,5624 5621 <br /> Ordering Information <br /> MethodIdentification <br /> .. <br /> Model Circuit on Exterior Rating Activation Ceiling* <br /> 5601 P Single None 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) <br /> 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) <br /> 5603 Single Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) <br /> 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) <br /> 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) <br /> 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) <br /> —► 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) <br /> 5624 Dual Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) <br /> `NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. <br /> SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. <br /> Product specifications subject to change without notice.Visit systemsensorcom <br /> Phone:800 SENSOR2•Fax:630 377 6495 or current product information,including the latest version of this data sheet. <br /> SENSOR" <br /> www.systemsensor.com SPDS30001.7/13 <br />