Laserfiche WebLink
Application Installation <br /> The SIGA-RM1 mounts to a standard North American two-gang The SIGA-RM1: mounts to North American 2-1/2 inch(64 mm) <br /> electrical box, making it ideal for locations where only one module deep 2-gang boxes and 1-1/2 inch(38 mm)deep 4 inch square <br /> is required. Separate 1/0 and data loop connections are made to boxes with 2-gang covers and SIGA-MP mounting plates.The <br /> each module. terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2) <br /> wire size. <br /> The SIGA-MRM1 is part of the UIO family of plug-in Signature <br /> Series modules. It functions identically to the SIGA-RM1, but takes <br /> advantage of the modular flexibility and easy installation that char- O <br /> acterize all UIO modules.Two-and six-module UIO motherboards <br /> are available.These can accommodate individual risers for each <br /> on-board module,or risers that are shared by any combination 0 ° <br /> of its UIO modules.All wiring connections are made to terminal <br /> blocks on the motherboard. UIO assemblies may be mounted in <br /> EDWARDS enclosures. <br /> Electronic Addressing ®� <br /> The loop controller electronically addresses each module saving ~ <br /> valuable time during system commissioning. Setting complicated <br /> switches or dials is not required. Each module has its own unique SIGA-MRM1: mount the UIOxR motherboard inside a suitable <br /> serial number stored in its"on-board memory".The loop control- EDWARDS enclosure with screws and washers provided. Plug the <br /> ler identifies each device on the loop and assigns a"soft"address module into any available position on the motherboard and secure <br /> to each serial number. If desired,the modules can be addressed the module to the motherboard with the captive screws.Wiring <br /> using the SIGA-PRO Signature Program/Service Tool. connections are made to the terminals on the motherboard(see <br /> wiring diagram). UIOxR motherboard terminals are suited for#12 <br /> to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. <br /> Personality Codes <br /> Signature modules require the Signature loop controller to down- Uo Motherboard <br /> load the personality code that determines how it will operate. <br /> The Riser Monitor Module provides personality codes 23 and 24, <br /> which are described below. -- -- -�--� <br /> PersonalityCode 23: Riser Monitor facto default Plug-in le <br /> (factory � Module <br /> Personality code 23 configures the Riser Monitor Module to moni- <br /> tor 70 Vac audio, 25 Vac audio, or 12 Vdc and 24 Vdc risers.A <br /> trouble condition is reported back to the panel wherever the volt- <br /> age on the riser drops below the trouble threshold.The hardware <br /> jumper on the Riser Monitor Module must be configured for either Cabinet or electrical enclosure <br /> 70 Vac or 25Vac/24Vdc/12Vdc. <br /> Personality Code 24:Telephone Riser Monitor <br /> Personality code 24 configures the Riser Monitor Module to Testing & Maintenance <br /> monitor telephone risers.A trouble condition is reported back to The module's automatic self-diagnosis identifies when it is defec- <br /> the panel whenever voltage on the riser drops below the trouble tive and causes a trouble message.The user-friendly maintenance <br /> threshold. program shows the current state of each module and other perti- <br /> The delay time from when the device falls below the trouble nent messages. Single modules may be turned off(de-activated) <br /> threshold to when it sends a trouble signal to the panel is user temporarily,from the control panel. <br /> definable in the appropriate data entry program.A delay of 5 to 75 Scheduled maintenance(Regular or Selected)for proper system <br /> seconds can be assigned to the device;the default delay period is operation should be planned to meet the requirements of the <br /> 15 seconds. Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and <br /> ULC CAN/ULC 536 standards. <br /> Warnings & Cautions Compatibility <br /> This module will not operate without electrical power.As fires fre- These modules are part of EDWARDS's Signature Series intelligent <br /> quently cause power interruption,we suggest you discuss further processing and control platform.They are compatible with EST3, <br /> safeguards with your fire protection specialist. EST3X and iO Series control panels. <br /> EDWARDS recommends that these modules be installed accord- <br /> ing to latest recognized edition of national and local fire alarm <br /> codes. <br /> Page 2 of 4 DATA SHE, E85001-0535 <br /> Not to be used for installa, purposes. Issue 1.1 <br />