Application Accessories <br /> The SIGA-HRD combination fixed temperature/rate-of-rise heat Detector mounting bases have wiring terminals that are acces- <br /> detector provides a 15°F(9°C)per minute rate-of-rise heat sen- sible from the"room-side"after mounting the base to the electrical <br /> sor for the detection of fast-developing fires, as well as a 135°F box.The bases mount to North American 1-gang boxes and to <br /> 3 <br /> (57°C)fixed temperature sensor for slow building-fires.The SIGA- /2 inch or 4 inch octagon boxes, 1/2 inches(38 mm)deep.They <br /> also mount to European BESA and 1-gang boxes with 60.3 mm <br /> HFD fixed temperature detector provides a 135°F(57°C)fixed fixing centers.The SIGA-SB4, SIGA-RB4, and SIGA-IB4 mount to <br /> temperature sensor for slow building-fires. North American 4 inch sq. electrical boxes in addition to the above <br /> boxes.They include the SIGA-TS4 Trim Skirt,which is used to <br /> cover the"mounting ears"on the base.The SIGA-AB4G mounts <br /> Compatibility to a 4 inch square box only. <br /> Signature Series heat detectors are compatible only with the Sig- <br /> nature Loop Controller. , <br /> SIGA-AB4G/T/LF SIGA-SB SIGA-IB SIGA-RB SIGA-LED <br /> Installation Audible Base Standard Base Isolator Base Relay Base Remote LED <br /> Signature Series detectors mount Remote LED SIGA-LED-The remote LED connects to the <br /> to North American 1-gang boxes, SIGA-SB or SIGA-SB4 Standard Base only. It features a North <br /> 3-1/2 inch or 4 inch octagon d American size 1-gang plastic faceplate with a white finish and red <br /> boxes,and to 4 inch square elec- self-locking tab alarm LED. <br /> trical boxes 1-1/2 inches(38 mm) SIGA-TS4 Trim Skirt-Supplied with 4 inch bases, it can also <br /> deep.They mount to European be ordered separately to use with the other bases to help hide <br /> BESA and 1-gang boxes with 60.3 surface imperfections not covered by the smaller bases. <br /> mm fixing centers. See mounting LED Indicator Sounder Bases-Signature Series sounder bases are designed <br /> base installation and wiring for for use where localized or group alarm signaling is required. <br /> more information. <br /> • SIGA-AB4G bases provide sounder capability to Signature <br /> Series to heat and smoke detectors.They are not intended <br /> for use with combination carbon monoxide detectors in Fire- <br /> Sensing and reporting technology plus-CO mode. <br /> The microprocessor in each detector provides additional benefits- • SIGA-AB4GT bases provide sounder capability to Signature <br /> Self-diagnostics and History Log,Automatic Device Mapping, and Series smoke and heat detectors,as well as carbon monox- <br /> Fast, Stable Communication. ide detectors when used with a SIGA-TCDR Temporal Pattern <br /> Generator. <br /> Self-diagnostics and History Log - Each Signature Series o SIGA-AB4G-LF bases provide 520 Hz low frequency <br /> detector constantly runs self-checks to provide important mainte- sounder capability to Signature Series smoke and heat detec- <br /> nance information.The results of the self-check are automatically tors, as well as carbon monoxide detectors when used with a <br /> updated and permanently stored in the detector's non-volatile SIGA-TCDR Temporal Pattern Generator.The SIGA-AB4G-LF <br /> memory. is suitable for applications requiring low frequency audible <br /> Automatic Device Mapping-The loop controller learns where tones. <br /> each device's serial number address is installed relative to other <br /> devices on the circuit.The mapping feature provides supervision <br /> of each device's installed location to prevent a detector from being Warnings & Cautions <br /> reinstalled(after cleaning etc.)in a different location from where it 0 This detector does not operate without electrical power.As <br /> was originally. fires frequently cause power interruption, discuss further safe- <br /> Fast Stable Communication-On-board intelligence means less guards with the local fire protection specialist. <br /> information needs to be sent between the detector and the loop • This detector does not sense fires in areas where heat cannot <br /> controller. Other than regular supervisory polling response,the reach the detector. Heat from fires in walls, roofs,or on the <br /> detector only needs to communicate with the loop controller when opposite side of closed doors may not reach the detector. <br /> it has something new to report. This heat detector by itself does not provide life safety protec- <br /> tion Use this detector with ionization and/or photoelectric <br /> smoke detectors. <br /> • This detector does not detect oxygen levels, smoke,toxic <br /> gases, or flames. Use this device as part of a broad-based <br /> life safety program which includes a variety of information <br /> sources pertaining to heat and smoke levels, extinguishment <br /> systems,visual and audible devices,and other safety mea- <br /> sures. <br /> • Independent studies indicate that heat detectors should only <br /> be used when property protection alone is involved. Never <br /> rely on heat detectors as the sole means of fire protection. <br /> Page 2 of 4 DATA S H E E- E85001-Ov47 <br /> Not to be used for installat.. roses. Issue 2.2 <br />