Laserfiche WebLink
convergjnt <br /> 450 Shattuck Avenue South,Renton,Washington 98057 <br /> Phone:425-272-2250 Fax:425-251-0949 <br /> Tnia d--t and the mrormanontdepict contamedrahown <br /> is the exclusive property of Convergent Technologies LLC and shall <br /> be handled as proprietary and confidential far--and must be <br /> returned upon request.Tha document cannot be reproduced by any <br /> a_without tha wnttan authorization of Convergent Technologies LLC. <br /> BPS6A NAC 1-Battery Calculation BPS6A NAC 2-Battery Calculation BPS6A NAC 3-Battery Calculation <br /> POWER SUPPLY DESIGNATOR NAC I POWER SUPPLY PREFIX 1 1 STANDBY DURATION REQUIRED(HRS) 24 POWER SUPPLY DESIGNATOR NAC I POWER SUPPLY PREFIX 2 STANDBY DURATION REQUIRED(HRS) 24 POWER SUPPLY DESIGNATOR NAC POWERSUPPI. PREFIX 3 STANDBY DURATION REQUIRED(HRS) 24 <br /> PANEL LOCATION Lower Level ALARM RING TIME REQUIRED(MIN) 15 PANEL LOCATION Lower Level ALARM RING TIME REQUIRED(MIN) 15 PANEL LOCATION Lower Level ALARM RING TIME REQUIRED(MIN) 15 <br /> AREASERVED Lower Level SPARE CAPACITY(%) 25% AREA SERVED Lower Level SPARE CAPACITY(%) 25% AREA SERVED Lower Level SPARE CAPACITY(%) 25% <br /> POWER SUPPLY BASE LOAD/AUXILIARY POWER OUTPUT POWER SUPPLY BASE LOAD/AUXILIARY POWER OUTPUT POWER SUPPLY BASE LOAD/AUXILIARY POWER OUTPUT <br /> PART# DESCRIPTION CITY SUPV.CURRENT(mA) ALARM CURRENT(mA) PART# DESCRIPTION CITY SU PV.CURRENT(mA) AWRM CURRENT(mA) PART# DESCRIPTION CITY SU PV.CU RRENT(mA) ALARM CU RRENT(mA) <br /> EACH TOTAL EACH TOTAL EACH TOTAL EACH TOTAL EACH TOTAL EACH TOTAL <br /> BP56A REMOTE BOOSTER POWER SU PP LY 1 70 70 270 270 BP56A REMOTE BOOSTER POWER SU PP LY 1 70 70 270 270 BPS6A REMOTE BOOSTER POWER SUPPLY 1 70 70 270 270 <br /> BPSAUX BPS CIRCUITS SETTO AUX OUTPUT 1 35 35 35 35 BPS AUX BPS CI RCUITS SET TO AUX OUTPUT 1 35 35 35 35 BPS AUX BPS CIRCUITS SETTO AUX OUTPUT 1 35 35 35 35 <br /> SIGA-CC15 ISICNAL MODULE WITH STROBE SYNC 1 1 0 0 1 6 6 SIGA-CC15 ISIGNAL MODULE WITH STROBE SYNC 1 0 0 6 6 SIGA-CC15 SIGNAL MODULE WITH STROBE SYNC 1 0 0 6 6 <br /> NAC/AUX OUTPUTS NAC/AUX OUTPUTS NAC/AUX OUTPUTS <br /> NAC/AUXOUTPUTS DESCRIPTION SU PV.CURRENT(mA) ALARM CURRENT(.A) NAC/AUXOUTPUTS DESCRIPTION SUPV.CURRENT(mA) ALARM CURRENT(mA) NAC/AUX OUTPUTS DESCRIPTION SUPV.CURRENT(mA) ALARM CURRENT(mA) <br /> CKT.#1 TYPE TOTAL TOTAL CKT.# TYPE TOTAL TOTAL CKT.# TYPE TOTAL TOTAL <br /> 1 AUX.POWER Shunt Trip Panel Power 0 15 1 AUX.POWER Shunt Trip Panel Power 0 15 1 AUX.POWER Shunt Trip Panel Power 0 15 <br /> 2 SPARE Spare 0 0 2 SPARE Spare 0 0 2 SPARE Spare 0 0 <br /> 3 SPARE Spare 0 0 3 SPARE Spare 0 0 3 SPARE Spare 0 0 <br /> 4 SPARE Spare 0 0 4 SPARE Spare 0 0 4 SPARE Spare 0 0 <br /> SUBTOTAL SUPERVISORY CURRENT(AMPS): 0.105 SUBTOTAL SUPERVISORY CURRENT(AMPS): 0.105 SUBTOTAL SUPERVISORY CURRENT(AMPS): 0.105 <br /> TOTAL SUPERVISORY CURRENT WITH STANDBY(AMPS): 2.520 TOTAL SUPERVISORY CURRENT WITH STANDBY(AMPS): 2.520 TOTAL SUPERVISORY CURRENT WITH STANDBY(AMPS): 2.520 <br /> SUBTOTAL ALARM CURRENT(AMPS): 0.326 SUBTOTAL ALARM CURRENT(AMPS): 0.326 SUBTOTAL ALARM CURRENT(AMPS): 0.326 <br /> TOTALALARM CURRENT WITH ALARM RING TIME(AMPS): 0.082 TOTALALARM CURRENT WITH ALARM RING TIME(AMPS): 0.082 TOTALALARM CURRENT WITH ALARM RING TIME(AMPS): 0.082 <br /> SPARE CAPACITY: 25% SPARE CAPACITY: 25% SPARE CAPACITY: 25% <br /> TOTAL AMP HOUR REQUIRED(AMPS): 3.252 TOTAL AMP HOUR REQUIRED(AMPS): 3.252 TOTAL AMP HOUR REQUIRED(AMPS): 3.252 <br /> convergInt BATTERY SIZE REQUIRED(Aft 7 convergInt BATTERY SIZE REQUIRED(AH): 7 convergInt BATTERY SIZE REQUIRED(AH): 7 <br /> BATTERY CABINET PROVIDED: NO BATTERY CABINET PROVIDED: NO BATTERY CABINET PROVIDED: NO <br /> JOBR-DESCRIPTION DALE BY <br /> OR <br /> I J00150M ISSUED FOR PERMIT <br /> 0 <br /> 0 <br /> w <br /> a Iaa,-PN-.-7l <br /> U DATE 0211312123 <br /> to <br /> Q <br /> U PROVIDENCE PACIFIC CAMPUS <br /> F <br /> ELEVATOR T.I. <br /> PACIFIC916 <br /> v EVERETT,WA,98201 <br /> x <br /> 0 <br /> M <br /> zz CALCULATIONS <br /> c� <br /> z FIRE ALARM SYSTEM <br /> WIND. <br /> o FA-5-1 <br /> LL <br />