My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3201 SMITH AVE BASE FILE 2025-09-24
>
Address Records
>
SMITH AVE
>
3201
>
BASE FILE
>
3201 SMITH AVE BASE FILE 2025-09-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2025 9:35:27 AM
Creation date
8/18/2025 9:50:18 AM
Metadata
Fields
Template:
Address Document
Street Name
SMITH AVE
Street Number
3201
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L w <br /> EXISTING FAC P EVE re D Ermit <br /> .. <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> f1simplex 41000 Fire Control 02/21/20PM12:39:09 <br /> UL, CSFM Listed, FM Approved, XA Loop Interface to the 4100ES or 41000 Fire <br /> MEA (NYC)Acceptance* Alarm Control Panel, Module 4100-3115 <br /> MITI M- XA device loop, Simplex IDNetTM <br /> Class B or Class A addressable devices <br /> Allows the Simplex 4100ES or 41000 to operate <br /> as either an XA Loop Master Panel or an XA Loop ------- <br /> Data Gathering Panel device <br /> When operating as an XA loop Master Panel: <br /> • Connects to up to 255 input devices and up to 255 output - <br /> devices on a single XA loop to monitor, supervise,and device <br /> control <br /> • Monitoring status includes Normal,Trouble,or Alarm XA � <br /> • XA loop devices can be 4-wire if command output device <br /> functions are used,or 3-wire if used for monitoring only <br /> • XA loop devices appear to the 4100ES/4100U similar to <br /> IDNetTM addressable devices including custom labels <br /> with up to 40 characters <br /> When operating as an XA loop Data Gathering Panel: <br /> • Communicates status and receives control from the XA <br /> loop's Autocall compatible Master Panel <br /> • Control includes Acknowledge,Silence,Reset,and ------ <br /> device level commands <br /> • 4100ES/4IOOU operates as a stand-alone fire alarm <br /> control panel for its connected devices and appliances 4100-3115 <br /> 4100ES or 41000 panels a ui ed with Sim lex XA Loop <br /> p q pp p Module <br /> Network communications can send XA loop <br /> device information to other Network nodes <br /> 4100ES/41000 Fire Alarm <br /> - Control Panel(4100ES shown) <br /> System Flexibility.When a fire alarm system using 4100ES/41000 XA Loop Interface Block Diagram <br /> existing XA loop devices requires expansion,use of the <br /> 4100-3115 XA Loop Interface Module allows the <br /> expansion to include the capabilities of the 4100ES or <br /> 410OU fire alarm control panel. This module allows the Power Requirements <br /> host control panel to be selected to function as either the 24 VDC from expansion bay <br /> XA loop master controller(head end)or as a Data Voltage power supply if present;or wired <br /> Gathering Panel as an intelligent device on the XA loop to AUX(+)and AUX(-)from <br /> reporting to a remote master controller. Auxiliary 24 VDC in panel <br /> Current 570 mA @ 24 VDC <br /> Multiple XA Loop Interface Modules can be XA Loop Specification Reference <br /> installed in the 4100ES/4I OOU allowing a variety of <br /> system expansion situations to be satisfied.The Maximum Resistance 100 Q per wire <br /> 4100ES/4100U accepts up to a total of 30 modules of this Maximum Capacitance 1.5 pF wire-to-wire <br /> type which also includes IDNet modules,MAPNET II® 1.5 pF wire-to-shield <br /> modules,and VESDA®modules Current 500 mA <br /> On-Board LEDs are provided for service diagnostics to Voltage/Frequency 24 VAC,250 Hz <br /> indicate XA loop status,internal 4100ES/4100U Maximum Addresses per Loop 1255 <br /> communications status,and supervision status when General Specifications <br /> functioning as a master controller for the XA loop. Operating Temperature Range 32°F to 120°F(0°C to 49°C) <br /> For additional information,refer to Installation and Up to 93%RH,non-condensing <br /> Programming Guide 579-513. Humidity Range @ 90°F(32°C) <br /> *This product has been approved by the California State Fire Marshal(CSFM)pursuant to 4"x 10"(102 mm x 254 mm) <br /> Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7165-0026:251 Mounting module requires two vertical <br /> (non-high rise)and 7170-0026:250(high rise)for allowable values and/or conditions expansion bay blocks <br /> concerning material presented in this document.It is subject to re-examination,revision,and <br /> possible cancellation.Accepted for use—City of New York Department of Buildings— On-board terminal blocks for field <br /> MEA35-93E.This product was not ULC listed as of document revision date.Additional Output Wiring Connections wiring 18 to 12 AWG(0.82 mm2 <br /> listings may be applicable;contact your local Simplex product supplier for the latest status. to 3.31 mm2) <br /> Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety <br /> Products Westminster. <br /> S4100-0041-3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.