Gamewell velocitiO Series <br /> _ FIRE CONTROL <br /> INSTRUMENTS MMO=6SF <br /> by Honeywell <br /> Description Multi-MOD Six Signal <br /> The Gamewell-FCI Velociti® Series, multi-mod six signal Output Module <br /> output module (MMO-6SF) provides six(6), Style Y (Class <br /> B)or three(3), Style Z(Class A)supervised control circuits - <br /> suitable for a wide range of signaling applications. Each <br /> supervised circuit may be used as a: <br /> • Audio speaker circuit. <br /> • Notification applicance circuit. <br /> • Supervised control output. <br /> The Velociti® Series use a communication protocol that <br /> substantially increases the speed of communication <br /> between the sensors and certain Gamewell-FCI analog <br /> addressable fire alarm controls. These devices operate in <br /> a grouped fashion. If one of the devices in the group has a <br /> status change,the panel's microprocessor stops the group <br /> poll and concentrates on the single device. The net effect MW-68F <br /> is response speed up to five times greater than earlier <br /> designs. Features <br /> The MMO-6SF connects to the signaling line circuits(SLC) . Each MMO-6SF module provides six(6),Style Y(Class <br /> of the Gamewell-FCI analog addressable series fire alarm B)or three(3), Style Z(Class A)individually address- <br /> control panels. Each of the MMO-6SF supervised control able, individually programmable notification appliance <br /> circuits occupies its own address on the system's SLC or supervised output circuits <br /> allowing each to be fully programmable in its control-by- • Removable wiring terminal blocks allow ease of installa- <br /> event sequence of operation. tion and servicing <br /> • Terminal blocks can accommodate 12 to 18 AWG wire <br /> The address of the first supervised output circuit is set with • Flexible jumper configuration feature allowing up to <br /> a pair of rotary dials. Each remaining circuit is automati- three(3), output circuit addresses to be disabled <br /> cally assigned to its own subsequent address. The MMO- • Accommodates multiple external power inputs <br /> 6SF module includes an address disable jumper matrix • External power monitoring <br /> that allows one, two, or three addresses to be turned off to • Short circuit protection of external power supplies <br /> free these addresses for other purposes. An additional • Sources providing AC, DC, or audio inputs <br /> jumper setting selects either Style Y or Style Z circuit con- • Designed for use with Gamewell-FCI analog address- <br /> figurations. A wide range of configurations are possible able series fire alarm control panels <br /> including 30 VDC, audio input at 25 or 70.7 VRMS, 125 • Individual LED indicators* <br /> VAC,etc. More than one circuit can share a power supply if • Ideal for retrofit applications <br /> the current capacity does not exceed the power supply's . Two(2), mounting cabinets available for two(2), (MBB- <br /> output. 2 cabinet)to six(6), (MBB-6 cabinet)units <br /> Each output circuit on the MMO-6SF monitors its own con- Note: *Only the red LED is operative in panels that do not <br /> nection to its power supply and will indicate a fault condi- operate in Velociti®mode. <br /> tion by address if the power source should fail. The MMO- <br /> 6SF is also provided with short circuit monitoring to protect <br /> SIGNALINGthe external power source from short circuits on the notifi- <br /> cation appliance circuit wiring.This feature can be disabled U� <br /> FM MEA <br /> per individual circuit if the application requires. LISTED APPROVED Approved <br /> Velociti®andB Series®are registered trademarks ofHoneyvvellInternational Inc. S1913 3023594 219-02-E Vol.VI 7300-1703:0124 <br /> ISO 9001 GAMEWELL-FCI <br /> Q�IIEITY SYSTEMS 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel: (203)484-7161 •Fax:(203)484-7118 <br /> Specifications are for infom ation only,are not intended for installation purposes,and are subject to change w thout notice.Nb responsibility is assumed by Cramewell-FCI for their use. <br /> 12013 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0634 Rev. D page 1 of 2 <br />