My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3201 SMITH AVE BASE FILE 2025-09-24
>
Address Records
>
SMITH AVE
>
3201
>
BASE FILE
>
3201 SMITH AVE BASE FILE 2025-09-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2025 9:35:27 AM
Creation date
8/18/2025 9:50:18 AM
Metadata
Fields
Template:
Address Document
Street Name
SMITH AVE
Street Number
3201
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications, Duct Smoke Detector Accessories <br /> APA151 Piezo Annunciator RTS1 51 Remote Test Station <br /> Voltage Regulated 24 VDC Power Requirements Alarm LED:2.8 to 32 VDC, 12 mA max. <br /> Operating Voltage 16 to 33 VDC Total Current: 105 mA max. <br /> Maximum Alarm Current 30 mA Test Switch 10 VA @ 32 VDC <br /> Temperature Range 0°C to 490C(32°F to 120°F) Reset Switch 10 VA @ 32 VDC <br /> Relative Humidity 10 to 93%non-condensing Alarm Response Time 40 seconds max. <br /> Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60oC(14°F to 140°F) <br /> Dimensions 4.6"H x 2.9"W x.45"D Relative Humidity 95%non-condensing <br /> ©Advance Wire Gauge 14 to 18 AWG <br /> Voltage Regulated 12 DC or FWR(Full Wave Dimensions 4.8-H x 2.90-W x 1.4-D <br /> Rectified)or Regulated 24 VDC or FWR RTS1 51 KEY Remote Test Station with Key <br /> Sounder Current Draw 22 mA RMS max.at 8 to 17.5 Volts DC Power Requirements Power LED(Green): 14 to 35 VDC, <br /> 29 mA RMS max.at 16 to 33 Volts DC 12 mA max. <br /> Temperature Range 0°C to 49°C(32°F to 120°F) Alarm LED(Red):2.8 to 32 VDC, <br /> Humidity Range 10 to 93%non-condensing 12 mA max. <br /> Nominal Sounder 3 kHz Total Current: 105 mA max. <br /> Frequency Alarm Response Time 40 seconds max. <br /> Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60oC(14°F to 140°F) <br /> Dimensions 4.6-H x 2.9-W x 0.45-D Relative Humidity 95%non-condensing <br /> Remote Annunciator Wire Gauge 14 to 18 AWG <br /> Voltage Range Conventional System:3.1 to 32 VDC Dimensions 4.6-H x 2.75-W x 1.8-D <br /> Intelligent System: 18 to 32 VDC RTS2 and RTS2-AOS Multi-signaling Accessory <br /> Maximum Alarm Current 10 mA Voltage 20 to 29 VDC <br /> Dimensions 4.6-H x 2.8"W x 1.3"D Power Requirements Standby:3.0 mA max. <br /> Trouble: 16.0 mA max. <br /> Alarm without strobe:30 mA max. <br /> Alarm with strobe:55 mA max. <br /> Sounder 85 dBA at ten feet <br /> Temperature Range —10°C to 60oC(14°F to 140°F) <br /> Relative Humidity 95%non-condensing <br /> Wire Gauge 14 to 22 AWG <br /> Dimensions 4.8-W x 5.3-H x 1.6-D <br /> For the very latest product specifications and listing information, <br /> please visit the System Sensor Web site at www.systemsensor.com. <br /> O � <br /> a SMOKE <br /> s <br /> RTS151 UL S4011 RTS151 KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 <br /> RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AOS <br /> fSYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. <br /> 1 Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensorcom <br /> w SOR^ for current product information,including the latest version of this data sheet. <br /> SENSOR www.systemsensor.com HVDS20202•8/13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.