My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6830 HIGHLAND DR 2025-09-11
>
Address Records
>
HIGHLAND DR
>
6830
>
6830 HIGHLAND DR 2025-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 2:20:07 PM
Creation date
8/18/2025 10:19:16 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGHLAND DR
Street Number
6830
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6820 COMPATIBLE DEVICES AND B20OS-LF:Low-frequency intelligent WSK-PHOTO-T.Wireless Multi-criteria <br /> ACCESSORIES sounder base photoelectric smoke detectorwith thermal <br /> See the data sheets listed below for a B224RB: Relay base detection(1350F fixed temperture)and <br /> complete listing of the SK,SD or SWIFT B224B1: Isolator base B51OW 4"base <br /> devices. WSK-HEAT:Wireless Heat,(1351Ffixed <br /> 53623:SK Devices Data Sheet SD COMPATIBLE ADDRESSABLE temperture)and B51OW 4"base <br /> 53624:SD Devices Data Sheet DEVICES WSK-HEAT-ROR:Wireless heat,ROR <br /> 350614,350616&350618:SWIFT SD505-6AB:Addressable 6"base (135°F fixed temperture)and 13510W 4" <br /> wireless devices SD505-61B:Addressable 6"short circuit base <br /> For a complete and current listing of isolator base WSK-MONITOR:Wireless monitor module <br /> compatible devices and accessories go to SD505-6RB:Addressable 6"relay base WSK-RELAY:Wireless relay module <br /> www.siLentknight.com SD505-6SB:Addressable 6"sounder base W-USB:SWIFT Tools USB transceiver used <br /> Important:You cannot mix SK and SD SD500-AIM:Addressable input module for communication with SWIFT devices <br /> devices in the same fire alarm system. (switch input) <br /> SD500-ANM:Addressable notification SBUS ACCESSORIES <br /> SK COMPATIBLE ADDRESSABLE module 6815:Each Single Line Circuit allows for <br /> DEVICES <br /> SK-ACCLIMATE:Multi criteria SD500-ARM:Addressable relay module an additional 159 SK modules and 159 SK <br /> SD505-DTS-K:Remote test switch and sensors to be added to the system-up to <br /> photoelectric smoke detector with thermal 1,110 total points.Supports System Sensor <br /> 135°F fixed tem temperture LED indicator for theSD505-DUCTR <br /> p SK devices only. <br /> SK-BEAM:Reflected beam smoke detector SD505-DUCT:Addressable Duct Smoke <br /> Detector. 5815XL:Each Single Line Circuit provides <br /> without test feature an additional 127 SD devices to be added to <br /> SK-BEAM-T.Reflected beam smoke SD actor housing <br /> Addressable Duct the system-for a maximum of 635 points. <br /> detector with test feature Detector housing with relay base. Supports SD devices only. <br /> SK-CONTROL:Supervised control module SD505-HEAT:Absolute temperature 5496:A 6 amp notification power expander <br /> heat detector.Trip point range from power-limited notification <br /> SK-CONTROL-6:Six circuit supervised 1350E-150°F(0°C-370C). with four p <br /> control module appliance circuit outputs. <br /> module <br /> SK-DUCT:Photoelectric duct smoke LIM:Addressable Line isolator 5883:Relay Interface.Provides 10 Form C <br /> module <br /> detector with extended airspeed range relays. <br /> SD500-MIM:Addressable Mini input <br /> SK-FIRE-CO:Four criteria fire and carbon monitor module(switch input) 5824:Serial/Parallel Printer Interface <br /> monoxide detector Module for printer connection. <br /> SK-HEAT:Fixed thermal detector(135°F) SD505-PHOTO:Photoelectric smoke detector 5895XL:Power Supply with six Flexputr"" <br /> Max.16 per <br /> s <br /> SK-HEAT-ROR:Fixed rate of rise detector SD500-PS/-PSDA:Addressable Single or stem.circuits,and two Form C relays. p <br /> (135 F) dual action pull station y <br /> SK-HEAT-HT:Fixed high temperature 5815RMK:Remote mounting kit. <br /> thermal detector(190°F) module <br /> SDM:Addressable smoke detector Dimensions 10 3/8"W x 10-3/16"H x 3"D <br /> odule <br /> SK-ISO:Fault isolator module <br /> COMMUNICATION OPTIONS <br /> SK-MINIMON:Mini monitor module AUDIBLE/VISIBLE DEVICES CELL-CAB-SK:Cellular communicator, <br /> SK-MONITOR:Monitor module These AV devices are all 2-wire.Color:°R" metal enclosure with lock/key* <br /> SK-MONITOR-2:Dual input monitor indicates red;"W"denotes white.Fora CELL-MOD:Cellular communicator,plastic <br /> module complete listing of Silent Knight AV devices enclosure* <br /> SK-MON-10:10 input monitor module go to www.silentknight.com. <br /> CHSRL/CHSWL:Wall chime/strobe Sole path,powered panel. <br /> SK-PHOTO:Photoelectric smoke detector IPGSM-4G:Dual path <br /> fire alarm <br /> SK-PHOTO-T.Photoelectric smoke CHSCRL/CHSCWL:Ceiling chime/strobe <br /> detectorwith thermal(135°Ffixed CHRL/CHWL:Watt chime communicator, grand/orlP(primary <br /> abl <br /> or backup,selectable) <br /> temperture) HRL/HWL:Wall horn SK-IP-2:Remote reporting via the Internet. <br /> SK-PHOTOR:Photoelectric detector with P2RL/P2WL:Wall horn/strobe Requires a VisorAlarm°receiver at the <br /> remote test capability PC2RL/PC2WL:Ceiling horn/strobe central station <br /> SK-PULL-SA:Addressable single action SRL/SWL:Wall strobe <br /> pull station SCRL/SCWL:Ceiling strobe MISC.ACCESSORIES <br /> SK-PULL-DA:Addressable dual action pull SPSCRL/SPSCWL:Ceiling speaker/strobe SK-NIC:Network Interface Card.Provides a <br /> station SPSRL/SPSWL:Wall speaker/strobe common communications link for the 6820. <br /> SK-RELAY:Addressable relay module SK-NIC-KIT:Installation Accessory Kit <br /> SK-RELAY-6:Addressable Six relay control SPRL/SPWL:Wall speaker SK-FML:Fiber-Optic Multi Mode, <br /> module SPCRL/SPCWL:Ceiling speaker transmitter and receiver <br /> SK-RELAYMON-2:Addressable Dual relay/ SWIFT WIRELESS DEVICES SK-FSL:Fiber-Optic Single Mode <br /> monitor module SWIFT is only compatible with RBB:Remote battery box accessory cabinet <br /> SK-ZONE:Addressable zone interface for batteries that are too large to fit in the <br /> module System Sensor(SK)devices.It is not FACP cabinet.Dimensions:16"W x 10"H x <br /> SK-ZONE-6:Six zone interface module compatible with Hochiki(SD)devices. 6"D(406mm W x 254mm H x 152mm D). <br /> B21OLP:6"mounting base WSK-WGI:Wireless Gateway SK-SCK:Seismic Compliance Kit used to <br /> B501:4"Flan eless mounting base securely fasten batteries to the fire panel. <br /> g g WSK-PHOTO:Wireless Photoelectric <br /> B20OS:Intelligent sounder base smoke detector <br />
The URL can be used to link to this page
Your browser does not support the video tag.