3003 W CASINO RD BLDG 07-587 2025-09-26
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 07-587
>
3003 W CASINO RD BLDG 07-587 2025-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2025 10:42:46 AM
Creation date
8/18/2025 10:36:04 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 07-587
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E) POTTER PSN SERIES <br /> ® The Symbol of Protection POWER SUPPLY <br /> PSN-106 Wiring Diagram <br /> 4'n 120/240 VAC GND FAULT <br /> Jumper Position DETECT ENABLE <br /> ON o o n OFF <br /> 120VAC 50Hz-60Hz <br /> 240VAC 50Hz-6OHz Black <br /> Connect to separate white <br /> unswitched AC circuit Ground status LBD s <br /> NACI NAC2 NAC3 NAC4 NAC5 NAC6 DCPWR <br /> ® ® ® aaaaaaaa aaaaaaaa <br /> Elo eases 3I <br /> H N COMM. <br /> Fuse0 ❑ o eases sx <br /> ❑❑ ° ° o °11 o eases 33 <br /> ° ° o Besse S4 <br /> Pac[ory Installed 0 ° ° <br /> Interconnect. a <br /> AC Power o eases SS <br /> Low Battery 0 <br /> Commault ❑ ❑ ❑ ❑ ❑ ❑ 0 eases S6 <br /> 8 ❑ El <br /> ease❑Bulk Options DEEDEE ❑ ❑ �❑ <br /> El <br /> ® ® ® ® ® ® ® ® NAC NAC2 NAC3 NAC4 NA 5 NAC6 CP R REF INl rN <br /> + <br /> NC CO M NO NC COM NO Battery+ <br /> Ll <br /> Common relays are Battery- <br /> Optional E.O.L. <br /> O <br /> non-power limited. Ref ce <br /> E.o.L. <br /> E.O.L. <br /> DC Power Trigger <br /> ii; - - + - + <br /> Battery connection(non-power limited). Note:PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power <br /> Use two(2)12V batteries connected in series. supply is triggered.There is no current draw in Standby Mode. <br /> Engineering Specification <br /> The contractor shall supply and install the Potter PSN power supply.The assemblies.The LEDs shall have distinct flash patterns to provide further <br /> power supply shall operate on either 120 or 240 VAC input.The panel indication ofthe troubles present.The panel shall have selectable Trouble <br /> shall be capable of continuous load power without any degradation to Memory to provide the installer an indication that a past trouble existed <br /> the main supply or the distribution board.The cabinet shall be capable of on a circuit for diagnostic purposes. <br /> housing up to 18 AH batteries and the panel shall be capable of charging Each output of the power supply shall be capable of 3 amps of continuous <br /> up to 55 AH batteries in an external cabinet. power without degradation over time.The power supply shall provide for <br /> The panel shall have dip switches for simplistic configuration of the multiple circuits of strobe appliances.The power supply shall synchronize <br /> system and LEDs to provide visual indication to the installer of the status the flashes of any of the above listed strobe appliances on a per circuit <br /> of the system.The dip switches shall allow forAC power delay selection, basis.Up to four different strobe circuits may be connected and all of <br /> Class A/B operation per output,Door Holder Power options,constant the strobes shall flash in unison as required by UL 864.In addition to <br /> auxiliary power,trigger input type,ANSI Code 3 Temporal Code,Pass this Quadrasync feature, the panel shall allow any of the four above <br /> Thru(input tracking),Potter/AMSECO®sync,Gentex®Sync, System mentioned sync patterns as an input and pass this signal through and <br /> Sensor®Sync or Wheelock®sync.The LEDs shall provide indication synchronize the outputs to match the input flash pattern. <br /> of communication between the power supply and distribution circuit <br /> PRINTED IN USA MKT.#8910013-REV D PAGE 2 OF 2 <br /> 1/18 <br />