My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6801 SEAWAY BLVD 2024 MCKESSON CORP 2025-09-12
>
Address Records
>
SEAWAY BLVD
>
6801
>
MCKESSON CORP
>
6801 SEAWAY BLVD 2024 MCKESSON CORP 2025-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2025 1:29:26 PM
Creation date
8/18/2025 11:00:01 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6801
Tenant Name
MCKESSON CORP
Year
2024
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Application <br /> Kidde VS Series life safety systems are powerful intelligent solutions Flexibility built right in <br /> for small to mid-sized buildings.Advanced intelligent technology Two fully-programmable front panel switch/LED combinations pro- <br /> delivers the benefits of flexible system installation,while clean and vide an added measure of flexibility.Their slide-in labels take the <br /> easy-to-operate user interfaces make panel operation and system mystery out of custom applications, and present a clean finished <br /> maintenance quick and intuitive. appearance. <br /> The smart choice Perfect for retrofits <br /> Electronic addressing eliminates the tedium of setting dipswitches, Kidde VS Series control panels are particularly well-suited to <br /> and automatic device mapping ensures that each device resides retrofit applications.All connections are made over standard wiring <br /> on the system at its correct location. Meanwhile, innovative pro- -no shielded cable required.This means that in most situations <br /> gramming allows the designer to customize the system to pre- existing wiring can be used to upgrade a legacy control panel <br /> cisely suit the needs of the building owner. to VS technology without the expense or disruption of rewiring <br /> the entire building.VS control panels also support the ingenious <br /> Reliability you can count on RZI16-2 zone module,which adds up to 16 conventional circuits <br /> The inherent fault-tolerant characteristics of Analog/Address- and two NACs.This combination easily accommodates new intel- <br /> able Technology boosts the reliability of Kidde fire alarm systems. ligent detection alongside existing conventional circuits, making it <br /> When combined with VS Series smoke and heat detectors,these an superior solution in the retrofit market. <br /> systems deliver a level of dependability not previously available <br /> for small to mid-sized applications.All Kidde systems are built to Signals with a difference <br /> exacting reliability benchmarks and meet international standards VS Series NACs are configurable to fully support the advanced <br /> for quality, in addition to agency listings for dependability. signaling technology of Kidde Genesis and Enhanced Integrity no- <br /> tification appliances.These devices offer precision synchronization <br /> Clear-cut remote annunciation of strobes to UL 1971 standards. For Genesis devices, enabling <br /> Remote annunciation is a strong suit of the VS Series fire alarm this feature allows horns to be silenced while strobes on the same <br /> systems. Up to eight annunciators can be installed on a single two-wire circuit continue to flash until the panel is reset. <br /> system. Compatible annunciators include a range of LED and LCD <br /> models that provide zone or point annunciation,as well as com- A complete line of accessories <br /> mon control capabilities.VS control panels also supports graphic VS Series life safety systems are supported by a complete line of <br /> annunciation with optional graphic annunciator interface modules. analog/addressable detectors, modules and related equipment. <br /> Each interface provides common control and 32 LEDs. Consult the Ordering Information section for details. <br /> Programming and remote diagnostics Dimensions <br /> Kidde VS Series life safety systems are simple to set up,yet offer (1) <br /> �Oz-� �03 (2) (3) NI <br /> advanced programming features that put these small building D7� <br /> panels into a class of their own.The auto programming feature O O O a0 •O O <br /> quickly gets the panel operational using factory default settings. l• I O <br /> Basic zone and point settings can be programmed through the T O O <br /> front panel interface,so the system is up and running in no time. 1 1 O <br /> O O <br /> For more advanced system configuration and correlation groups O1 1 D4 <br /> programming,VS Series systems interface to a PC running com- O <br /> O O <br /> patible VS-CU software.This option offers full system configura- <br /> tion in the familiar Windows®operating environment. Connection is ° ® o <br /> made to a laptop through the panel's optional RS-232 communi- <br /> cations port,which can also be used to connect a system printer. <br /> Among the many innovative features of VS Series control panels �-D6� 'I <br /> is the optional network card.This module provides a standard (1)Surface Mounting Holes (3)Backbox with Door Attached <br /> 10/100 Base T Ethernet®network connection that permits access (2)Semi-flush mounting Holes (4)Backbox with door and trim kit attached. <br /> to the control panel from any remote location with the correct <br /> communications protocols.The connection can be used to down- Panel dimensions,in(cm) <br /> load to the panel from the VS-CU,or upload and view system Mode( Di* D2 D3 D4 D5* D6 D7 D8 D9 <br /> reports using the VS-CU. VS4 28.0 3.85 9.0 22.0 15.75 10.25 4.9 30.1 2.7 <br /> (71.1) (9.8) (22.8) (55.8) (40.0) (26.0) (12.4) (76.4) (6.8) <br /> Available system reports include: vS1 21.5 3.85 7.5 15.5 14.25 10.25 4.9 23.6 2.7 <br /> (54.6) (9.8) (19.0) (39.4) (36.2) (26.0) (12.4) (59.9) (6.8) <br /> • Correlation groups • Device details *Add 1-112 in.(3.81 cm)to D1 and D5 dimensions for trim kit.The trim kit <br /> • Device maintenance • History provides 0.75 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. <br /> • Internal status • System configuration <br /> • System status • Walk test <br /> • Dialer • CO runtime <br /> Page 2 of 8 DATA S H� V85005-0135 <br /> Not to be used for insta Issue 1 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.