My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6801 SEAWAY BLVD 2024 MCKESSON CORP 2025-09-12
>
Address Records
>
SEAWAY BLVD
>
6801
>
MCKESSON CORP
>
6801 SEAWAY BLVD 2024 MCKESSON CORP 2025-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2025 1:29:26 PM
Creation date
8/18/2025 11:00:01 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6801
Tenant Name
MCKESSON CORP
Year
2024
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications <br /> VS1 VS4 <br /> Device loops 1 loop Class B or Class A(Styles 4,6,7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), <br /> 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 <br /> modules) detectors and 125 modules max.).Addresses 1 to 125 are <br /> Maximum T-taps:63 for detectors and addresses 126 to 250 are for modules <br /> (each device can be on its own branch) Maximum T-taps/loop: 124 <br /> Notification appliance 2 Class B(Style 1),Class A(Style Z)optional 4 Class B(Style 1r)or 2 Class A(Style Z) <br /> circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz <br /> 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz <br /> 2.5 A FWR each max.per circuit 2.5 A FWR each max.per circuit <br /> Primary power 120 VAC,60 Hz, 1.3 A max. 120 VAC,60 Hz,2.0 A max. <br /> 230 VAC,50-60 Hz,0.62 A max. 230 VAC,50-60 Hz,0.97 A max. <br /> Base panel current standby 155 mA 172 mA <br /> Base panel current alarm 204 mA 267 mA <br /> Input zones 16 max. 32 max. <br /> Remote annunciator 8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B <br /> Data line length:4,000 ft.(1,219 m) Data line length:4,000 ft.(1,219 m) <br /> Operating voltage 24 VDC panel <br /> Auxiliary power output Aux power 1:500 mA,24 VDC <br /> circuit Aux power 2:500 mA,24 VDC(1 A possible if you reduce total available NAC power by 500 mA) <br /> Output:28.3 to 21.9 VDC,special application <br /> Note:For a list of compatible devices,see the VS1 and VS4 Series Compatibility List(P/N 3102354-EN) <br /> Loop circuit Maximum loop resistance:66 0 <br /> Maximum loop capacitance:0.5 uF <br /> Communication line voltage: Maximum 20.6 V peak-to-peak <br /> Operating current(fully loaded loop)Stand by:55 mA/45 mA <br /> Alarm: 125 mA/115 mA(not including two-wire smoke modules) <br /> Circuit current:0.5 A max.Style 4,6,and 7 wiring <br /> Max.resistance between isolators: Limited only by overall wire run lengths <br /> 64 isolators maximum per loop(total both isolator bases and modules) <br /> Batteries Type:Sealed lead acid <br /> Voltage:24 VDC <br /> Charging current:2.47 A max.Amp hour capacity:26 Ah <br /> Standby operation:24 hour or 60 hour <br /> Placement: Up to two 10 Ah batteries will fit in the VS1 control panel cabinet and two 18 Ah batteries will fit in the VS4 <br /> control panel cabinet. If larger batteries are required,use a battery cabinet. <br /> SA-DACT dialer Phone line type:One or two loop-start lines on a public,switched network <br /> Phone line connector: RJ-31/38X(C31/38X) <br /> Communication formats:Contact ID(SIA DC-05) <br /> Operating current Standby/Alarm:41 mA Max.: 100 mA <br /> FCC registration number:GESAL01 BSADACT <br /> Industry Canada Registration number:3944A-SADACT <br /> Ringer equivalence number:0.1 B <br /> Ground fault impedance 0 to 5 kQ <br /> Alarm contact Form C N.O.24 VDC at 1 A(resistive load) <br /> Trouble contact Form C 24 VDC at 1 A(resistive load) <br /> Supervisory contact Form A N.O.24 VDC at 1 A(resistive load) <br /> Environmental Temperature:0 to 49°C(32 to 120°F)Relative humidity:0 to 93%noncondensing <br /> Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm2) <br /> Page 7 of 8 DATA S h, V85005-0135 <br /> Not to be used for instz Issue 1 <br />