Laserfiche WebLink
__._.._.._.-___......�__.......„_.---__....--..--_ _-._. _.-__.-.w_�_..._........._..__...---.---.-- .LYON 1 KILDARE <br />' 73042110 <br /> T e Qly Ply .__ DTR78020937 <br /> Tot Common 10 1 <br /> .-._...------- -- ----------...._....-__._ -----_-- _-- Job Referenc_e_�Optional)-____-- <br /> Louws Truss,Inc, Femdafe,WA-98248, 8.530 s Aug 2 2023 MiTek Industries,Inc. Wed Aug 2318:05:55 2023 Page i <br /> ID:Yj4l3ODlJzAFepdzJJDykOykvr5-UFdOMg EMbg6vL5Rdm-iimmRUC13Dp&ikO9gm9?ykuGq <br /> -2.0.0 7.7.12 15-3-8 17-3-8 <br /> -2-0-0 7_7_12------ -- I--- - ---- 7 7 12 ---2-0-0 i <br /> i <br /> I Scale=1:34.2 <br /> 4x4 fl <br /> /3 <br /> 6.00[12 `\ <br /> 11 12 <br /> 10 13 <br /> 9 14 <br /> 6x6= 6x6= <br /> 2 4 <br /> 7 <br /> 3x4 11 400= 6 3x4 Il <br /> i <br /> i <br /> �----- 7-7-12 - <br /> i 7-7-12 <br /> I Plate Offsets(X,Y)-- 12:0-2-8,0-2-0_1L[3:0-2-12,0 2.01,14:0-2-8,0-2-01_-„ <br /> LOADING (pit) SPACING- 2-0-0 CSI. DEFL, In (loc) Udefl Ud PLATES GRIP <br /> TCLL 25.0 plate Grip DOL 1.15 TC 0.93 Vert(LL) -0.06 6-7 >999 360 MT20 2201195 <br /> (Roof Snow 25.0) Lumber DOL 1.15 BC 0,40 Vert(CT) -0.11 6-7 >999 240 <br /> TCDL .0 Rep Stress Incr YES WB 0.08 Horz(CT) 0.00 6 rda n1a <br /> BCLL 0.0 BCDL 10.0 Code IBC20181TP12014 Matrix-SH Wind(LL) 0.01 7 >999 240 Weight:78 lb FT=10% <br /> LUMBER- BRACING- <br /> TOP CHORD 2x4 DF No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purtins, <br /> BOT CHORD 2x4 DF No2 except end verticals, <br /> WEBS 2x4 DF No2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. <br /> REACTIONS. (size) 8=0-5-8,6=0-5-8 <br /> Max Horz 8=-95(LC 12) <br /> Max Uplift 8=-183(LC 14),6=-183(LC 15) <br /> Max Grav 8=853(LC 21),6=853(LC 22) <br /> FORCES. (Ib)-Max.Comp./Max.Ten.-Ail forces 250(Ib)or less except when shown. <br /> TOP CHORD 2-3=-74 9124 3,34=-74 9124 3,2-8=-7861361,4-6=-7861361 <br /> SOT CHORD 7-8=-1631374,6-7=-1141374 <br /> WEBS 3-7=01270,2-7=-211437,4-7=-231437 <br /> NOTES- <br /> 1)Wind:ASCE 7-16;Vuft=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=3.Opsf;h=25fl;Cat.11;Exp C;Enclosed; <br /> MWFRS(envelope)gable end zone and C-C Exterior(2E)-2-0-0 to 1-7-3,interior(1)1-7.3 to 7-7-12,Exterior(2R)7-7-12 to 11-2-15. <br /> Interior(1)11-2-15 to 17-0-8 zone;cantilever left and right exposed:end vertical left and right exposed;C-C for members and forces <br /> &MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 <br /> 2)TCLL:ASCE 7-16;Pf=25.0 psf(Lum DOL=1.15 Plate DOL=1.15);Is=1.0;Rough Cat C;Partially Exp.;Ce=1.0;Cs=1.00;Ct=1.10 <br /> 3)Unbalanced snow loads have been considered for this design. <br /> 4)This truss has been designed for greater of min roof live load of 18.0 psi or 2.00 times fiat roof load of 25.0 psf on overhangs <br /> non-concurrent with other live loads. <br /> 5)Plates checked for a plus or minus 115 degree rotation about its center. <br /> 6)This truss has been designed for a 10.0 psf bottom chord tive load nonconcurrent with any other live loads. <br /> 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2.0-0 wide -,j'y0NI0 ' <br /> will fit between the bottom chord and any other members. <br /> 8)Provide mechanical connection(by others)of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s)except et--lb) O� 04 ASNt� y, <br /> 8=183,6=183. <br /> 9)This truss is designed in accordance with the 2018 International Building Code section 2306.1 and referenced standard ANSVTPI 1. O <br /> 49639 AW. <br /> Off, �l'CIST6Rf'4 <br /> �SSIQNAL��� <br /> August 25,2023 <br /> ®WARNING-Verify destgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.N272023 BEFORE USE. <br /> Design valid for use only with MiTekO connec m rs tors.This design Is based only upon paraete shown,and Is for an individual building component,not MiTek" <br /> a buss system.Before use,the builcirg designer must verify the applicability of design parameters and property incorporate this desgn Into the overal <br /> burd'arg design.Bracing indicated Is to prevent budding of Individual truss web and/or Word members only.Adddional temporary and permanent bracing <br /> is aWiys required for stability and to prevent collapse with possite personal iyury and property damage.For general guidance regarding the 400 Sunrise Ave.,Suite 270 <br /> fabrioation,storage,delivery,erection and Macktg of trusses and truss systems,we ANSUTPII Quality Criteria and DSB•22 available from Truss Piale tnstitule(v ww.tpinsLwg) Rosevi@e,CA 95661 <br /> and SCSI Building Component Safety information ovalaue from via Structural Balding Component Association(www.sbcsonmponenls-can) 9116,755.357111 MiTek-US ram <br />