i <br /> i <br /> I <br /> 2u.18 Washington State Energy Code--Residetwal <br /> .Prescriptive Energy Code Compliance for All Climate Zones in Washington <br /> Sin le'Famil --New&Additions effective ebrua 1 2021 version 1.1 <br /> These requirements apply to all IRC building types,including detached one- and two-family <br /> dwellings and multiple single-family dwellings(townhouses). <br /> ......... <br /> E Project information Contact Information <br /> 13FT57- 0077 <br /> Instructions:This single-family project will use the requirements of the Prescriptive Path below and <br /> incorporate the minimum values listed.Based on the size of the structure,the appropriate riumber of <br /> i <br /> additional credits are checked as chosen by the permit applicant. <br /> Provide all information from the following tables as building permit drawings:Table R402.1-Insulation and <br /> Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits. <br /> Authorized Representative i �f� / Date �, _ <br /> I P e �r L.d :I `Z `CD -Z, <br /> - - <br /> AII_�Iimate Zones(table..R402, 1�- — --—........ <br /> __.. . -- --- <br /> R Value U-Factors <br /> Fenestration U-Factor b n/a f 0.30 <br /> __...................._........... ..._._._........._....-------...........__.....__.......... .... . .................----------- ...._....._._......__....._ _.._......_._........ ....: <br /> Sky light„U-Factorb n/a_.....----.-.._............._._. 0.50 <br /> __..__..__.....—— --........._ ._. _ _ _..................... <br /> _-._....--._.... .. . <br /> Glazed Fenestration SHGC b,e n/a I n/a <br /> C... -.....-.e-.... .......... .............................__._......._........................,._._._......................................................._._.................................._...._....._...._..... . ....... ............... <br /> Wood Frame Wall a,b 21 int 0.055 __.._.........._._....._............ <br /> _._..........-........_.....--..-......_... _...._......_....... . .. . <br /> Floor 30 i 0.029 <br /> :Below Grade WaII c.b 10/15/21 int+TB i- .............__-0.042 --------- - <br /> €--- -- - -- ... ........................._..__ __..__.._.......—_.............._____ __._.--- --..._.._........._..._-.-.-........_...._. __... _......---- ------............._...... <br /> Slab", R-Value&Depth 10,2 ft n/a <br /> ( j R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity that is less I <br /> a than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix <br /> Table A101.4 shall not be less tha.... _._.._..._................_........._._..._.._.............. <br /> b j The fenestration U-factor column excludes_skylights <br /> 10/15/21+5TB"means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on i <br /> I the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at I <br /> c 3 the interior of the basement wall."10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on <br /> the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall.05TB" <br /> means R-5 thermal break between floor slab and basement wall. <br /> ...-.-... -.._.............................. <br /> 1 d J R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. <br /> _..... _. ...... _...- <br /> e For single rafter-or joist-vaulted ceilings,the Insulation may be reduced to R-38 if the full insulation depth <br /> i extends over the top plate of the exterior wall. <br /> — _ . .._._... __...- ----- ---- -------- r_... -----: <br /> R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter <br /> I f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used,it shall <br /> meet the requirements for thermal barriers protecting foam plastics. <br /> _......... ..... <br /> i For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements far <br /> g climate zone 5 of ICC 400 <br /> -- - ---- --- -_._ .----- ---._.. ...........__._.... _- - ------ - - ---- _.._...._.....-- <br /> I Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard <br /> h ;framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 <br /> insulation. <br /> Prescriptive Path—Single Family 2018 Washington State Energy Code-R 1 <br />