Laserfiche WebLink
e. Where the building is not visible from the street or a single access road or private roadway <br /> serves more than one building,provision shall be made to clearly identify which driveway or <br /> roadway serves the appropriate address. <br /> 2. Surface(Emergency Access)Code Requirement: <br /> • Approved Fire Apparatus Access Roads shall be constructed of asphalt,concrete or other <br /> approved driving surface capable of supporting the imposed load of fire apparatus weighing <br /> at least 75,000 pounds. <br /> 3. Vertical Clearance(Emergency Access)Code Requirement: <br /> • Fire Apparatus Access Roads shall have an unobstructed vertical clearance of not less than <br /> 13 feet 6 inches. <br /> 4. Grade(Emergency Access)Code Requirement: <br /> • Fire Apparatus Access Roads shall not exceed 10 percent(10%)in grade longitudinally.Cross <br /> Slope of a road section or within a turnaround area shall not exceed five percent(5%).In <br /> order to accommodate proper angles of approach and departure,the gradient in fire access <br /> roads shall not exceed a five percent(5%)change along any ten(10)foot section. <br /> Page <br /> SS2S20-00202 <br /> EVERETT <br />