• Please see'A402 Section'as I have added labels to the Exterior wall assembly. <br /> To meet with vapor barrier requirements, I have revised the exterior wall assembly to <br /> be comprised of 2"thick closed cell rigid foam installed against the exterior siding <br /> to be secured in place with'foamboard construction adhesive'and seated in <br /> place alongthe edges with spray foam.The rest of the space will be filled with R-15 fiberglass. <br /> This should satisfy vapor barrier requirements while providing a betterthan required R-rating <br /> 4. Please provide dwetting-garage separation per IRC table R302.6 accordingly. <br /> • Please see sheet'A402 Section'where I have added 5/8"type X GWB to the garage ceiling, <br /> and after demo'ing existing 5/8"interior GWB on the North wall to replace the existing <br /> insulation with the rigid foam and R-15 detail, I will replace in kind with new 5/8"GWB. <br /> 5. Per WSEC-R 2021, please refer to WSEC-R Table R402.1.3 for watt insulation and window u-factor <br /> requirement. <br /> I think l understand howthis works. Please see how table below explaining each condition: <br /> Fenestration U-factor- 0.30 Required I will be replacing the old windows and sliding door that are only U- <br /> 0.24 for Energy factor 0.50 with windows that are under 0.24.Compliant. <br /> credits <br /> Skylight"U-factor- NoW14.project <br /> Ceiling U factor- 0.026 Required Unvented 2"closed cell rigid insulation R-10 <br /> R21+R212x12joist 24 o.c.=0.019.Welt above Compliant. <br /> Above grade wall U factor 0.056 Required RA103.2.3 Advanced <br /> 2x6 @2ft oc,2 stud insulated corners <br /> Closest I could find,as I will exceed this with R-25 in a similar <br /> configuration <br /> Table RA103.3.1(5)R21batt T-1-11 ADV=0.053. Compliant. <br /> Floor U-factor 0.029 Required Table RA105.1(1) R-30 Floor, R-0 perimeter=0.029. Compliant <br /> I reallythink I have R-30 Floor, R-11 Perimeter=0.028. Compliant <br /> Stab of grade,F-factor None�n projc " <br /> Betow grade 2'17epth None�r►prpect .. <br /> Below'; rade 3 5'Depth Nong�nrpjec# <br /> . " <br /> 6etbw'grade 'Depth None to prpjec# <br /> 6. Please add smoke detector and heat detector per IRC 314.2,and add CO alarm per IRC <br /> 315.2.And please indicate that smoke detector,heat alarm and CO monitor are <br /> interconnected, hardwired with battery backup per IRC 314.4&314.6&315.5&315.6. <br /> •Smoke/Carbon monoxide combo(per R315.5)and separate but intertied <br /> heat alarm added to'A102 Reflected ceiling plan'. <br /> • Both will be on dedicated circuit per(R314.6),shown on'E101 Electrical panel'. <br /> •Since there is only one room,one of each will be installed. <br /> •Smoke/CO alarm is over 3ft from bathroom,and Heat alarm is over 10 ft from stove <br /> to avoid false alarms per R314.3. <br />