My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5718 COMMERCIAL AVE B 2025-09-10
>
Address Records
>
COMMERCIAL AVE
>
5718
>
5718 COMMERCIAL AVE B 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 10:31:32 AM
Creation date
8/18/2025 3:08:11 PM
Metadata
Fields
Template:
Address Document
Street Name
COMMERCIAL AVE
Street Number
5718
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Greg Raymond <br /> 5718 Commercial Ave Unit B <br /> B2405-066 <br /> b. Two complete sets of revised construction drawings, cloud all revised parts. <br /> c. Two copies of supplemental structural calculations (if applicable). <br /> Submittal documents should contain sufficient information and detail to review the proposed project <br /> for compliance with the adopted building codes. Upon submittal of the revised documents, your <br /> application will be given priority and the review will recommence. <br /> Architectural (Reviewer: Yin Lu, R.A.) <br /> 1. Please look up the permit record and include complete, uncropped existing drawing if you <br /> want to refer to that. <br /> https://Ifportal.everettwa.gov/WebLink/DocView.aspx?id=893856&searchid=34196219- <br /> 92ec-4aa4-813b-2e7738cle78d&dbid=0 <br /> 2. Please refer to City of Everett Residential Construction Submittal Checklist, page 2, II <br /> Structural plan requirement, item 2 for floor plan requirement. <br /> https://www.everettwa.gov/DocumentCenter/View/117/Residential-construction-submittal- <br /> checklist-PDF <br /> 3. This proposal is converting an unconditioned and unhabitable space to a habitable space, <br /> please provide wall assembly design accordingly. The wall assembly should include exterior <br /> finish, sheathing, water resistance barrier, stud, insulation, vapor retarder, drywall, <br /> PT wood and etc.. <br /> 4. Please provide dwelling-garage separation per IRC table R302.6 accordingly. <br /> 5. Per WSEC-R 2021, please refer to WSEC-R Table R402.1.3 for wall insulation and window u- <br /> factor requirement. <br /> 6. Please add smoke detector and heat detector per IRC 314.2, and add CO alarm per IRC <br /> 315.2. And please indicate that smoke detector, heat alarm and CO monitor are <br /> interconnected, hardwired with battery backup per IRC 314.4 & 314.6 & 315.5 & 315.6. <br /> 7. Please provide unvented roof assembly design per IRC 806.5 accordingly. Unvented roof <br /> assembly is permitted when the listed conditions are met, kindly indicate which condition(s) <br /> work for this project. <br /> 8. Please indicate the new addition whole house ventilation design on the floor plan <br /> accordingly. IRC Table M1505.4.3(1-3). Please indicate the cfm, cont. vs intermitted, 1.0 <br /> sone max and all requirements will be met. <br /> 9. Please provide kitchen local exhaust per IRC Table M1505.5.4.4(1). <br /> 10. Please claim additional energy credit per WSEC 406.3 for new conditioned habitable space. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> 3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.