My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8909 CORBIN DR 2025-09-10
>
Address Records
>
CORBIN DR
>
8909
>
8909 CORBIN DR 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 10:47:36 AM
Creation date
8/18/2025 3:44:04 PM
Metadata
Fields
Template:
Address Document
Street Name
CORBIN DR
Street Number
8909
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ktuecuve r-eo. .i, zuci <br /> WAC 51-51-0330 <br /> Section R330—Adult family home <br /> SECTION R330 <br /> ADULT FAMILY HOMES <br /> R330.1 General.This section shall apply to all newly constructed adult family homes and all existing single family homes being <br /> converted to adult family homes. This section shall not apply to those adult family homes licensed by the state of Washington <br /> department of social and health services prior to July 1, 2001. <br /> R330.2 Reserved, <br /> R330.3 Sleeping room classification. Each sleeping room in an adult family home shall be classified ss: <br /> 1. Type S-Where the means of egress contains stairs, elevators or platform lifts. <br /> 2. Type NS1 -Where one means of egress is at grade level or a ramp constructed in accordance with R330.9 is provided. <br /> 3. Type NS2-Where two means of egress are at grade level or ramps constructed in accordance with R330.9 are provided. <br /> R330.4 Types of locking devices and door activation.Ali bedroom and bathroom doors shall be openable from the outside when <br /> locked. <br /> Every closet shall be readily openable from the inside. <br /> Operable parts of door handles, pulls, latches, locks and other devices installed in adult family homes shall be operable with one <br /> hand ands all not re uirq e tight grasping pinchingor twisting of the wrist. Pocket doors shall have graspable hardware available <br /> when in the closed or open position. <br /> The force required to activate operable parts shall be 5.0 pounds(22.2 N) maximum. Required exit doors shall have no additional <br /> locking devices. <br /> Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing reentry into the adult <br /> family home without the use of a key,tool or special knowledge. <br /> R330.5 Smoke and carbon monoxide alarm requirements.All adult family homes shall be equipped'iwith smoke and carbon <br /> monoxide alarms installed as required in Sections R314 and R315.1. Alarms shall be installed in such a manner so that the <br /> detection device warning is audible from all areas of the dwelling upon activation of a single alarm. <br /> R330.6 Escape windows and doors. Every sleeping room shall be provided with emergency escape and rescue windows as <br /> required by Section R310. No alternatives to the sill height such as steps, raised platforms or other devices placed by the openings <br /> will be approved as meeting this requirement. <br /> R330.7 Fire apparatus access roads and water supply for fire protection.Adult family homes shall be served by fire apparatus <br /> access roads and water supplies meeting the requirements of the local jurisdiction. <br /> R330.8 Grab bar general requirements.Where facilities are designated for use by adult family home:clients, grab bars for water <br /> closets, bathtubs and shower stalls shall be installed according to this section. <br /> R330.8.1 Grab bar cross section. Grab bars with a circular cross section shall have an outside diameter of 1 1/4 inches minimum <br /> and 2 inches maximum. Grab bars with noncircular cross section shall have a cross section dimension iof 2 inches maximum and a <br /> perimeter dimension of 4 inches minimum and 4 5/8 inches maximum. <br /> R330.8.2 Grab bar installation. Grab bars shall have a spacing of 1 1/2 inches between the wall and the bar. Projecting objects, <br /> control valves and bathtub or shower stall enclosure features above, below and at the ends of the grab'bar shall have a clear space <br /> of 1 1/2 inches to the grab bar. <br /> EXCEPTION: Swing-up grab bars shall not be required to meet the 1 1/2 inch spacing!requirement. <br /> Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar, fastener, mounting device or <br /> supporting structural member. Grab bars shall not be supported directly by any residential grade fiberglass bathing or showering <br /> unit. Acrylic bars found in bathing units shall be removed. <br /> Fixed position grab bars, when ounted, shall not rotate, spin or move and have a graspable surface finish. <br /> R330.8.3 Grab bars at water c�osets.Water closets shall have grab bars mounted on both sides. Grab bars can be a combination <br /> of fixed position and swing-up burs. Grab bars shall meet the requirements of R330.8. Grab bars shall;mount between 33 inches <br /> and 36 inches above floor grad . Centerline distance between grab bars, regardless of type used, shill be between 25 inches <br /> minimum and 30 inches maxim m. <br /> Implementation Date: 2021 February 01 <br /> Updated: 2021 February <br /> .._.._._.—_....... <br />
The URL can be used to link to this page
Your browser does not support the video tag.