Laserfiche WebLink
SmartOneOj Kidde <br /> Addressable Contact Input Device Fire Systems <br /> Effective: May 2020 <br /> K-76-701 <br /> FEATURES <br /> • Monitors N.O. or N.C. Unpowered Contacts • Class B Initiating Device Circuit <br /> • Full Digital Communications • Maximum 100 Ohm Loop Resistance(both conductors) <br /> • Remote LED Output • UL Listed, ULC Listed <br /> • Alarm Test from Control Unit Keypad • FM Approved <br /> DESCRIPTION <br /> The SmartOne® Addressable Contact Input Device (AI) is an rMONITORR.,.mo <br /> MODELAl <br /> intelligent field device with its own microprocessor, memory and electronics necessary to interface N.O. or N.C. unpoweredcontacts to Kidde® intelligent control units. All of the electronics are contained in a high-impact polymer case, creating a very <br /> small and durable device for installation.A silicone-free version is <br /> available for applications where silicone is not desired. <br /> Two types of Al's are available: an AI/NC for interfacing to nor- SPECIFICATIONS <br /> mally-closed devices and an AI/NO for interfacing to normally- IDC Wiring Style:Wired as NFPA 72 Class B <br /> open devices. The Al may be located up to 3,500 feet from the Input Voltage: 24 VDC nominal <br /> monitored device with#18 AWG wiring. An end-of-line-resistor is Standby Current:580 IJA Max <br /> required for supervision of the wiring to the device. Alarm Current: 580 pA Max <br /> FIELD PROGRAMMING Max. Circuit Resistance: 100 Ohm(50 Ohm to conductor) <br /> System address, owner location message and reporting type are Operating Environment:-31 to 151°F(-35 to 66°C)at 0 to 95% RH <br /> programmable via the compatible control unit configuration soft- LED Pulse Modes: <br /> ware program. The system address is a 3-digit number that Normal: 9 second interval <br /> uniquely identifies each device. The owner location message is a Trouble: LED is off <br /> 40-character, alpha numeric message that describes the location Alarm: 2 second interval <br /> of the device. The reporting type is assigned to the Al depending Acceptable Wire Size: 14, 16, 18 AWG <br /> on the functionality of the device being monitored. The Al can be mounted in a North American 2-1/2-in. (64 mm)deep, <br /> SUPERVISION 1-gang box or standard 4-in.square box, 1-1/2-in.(38 mm)deep with <br /> cover. <br /> The Al continuously monitors the integrity of the following: <br /> COMPATIBLE CONTROL UNITS <br /> • Continuity of supervised wiring <br /> • Power/Communications circuit voltage Fire Alarm Current Legacy <br /> • Internal power supply Control Unit Product Product <br /> • Memory data (FACU)Type <br /> • Faulty entering of data into Al memory Single Loop ARIES®-SLX ARIES <br /> STATUS LED FenwaINET'"6000 <br /> A remote status LED may be connected to the Al. MICRO SLX <br /> PEGAsys"* <br /> Any Aor all RM TEST <br /> can be tested by command from the compatible FenwaINET 2000* <br /> control unit. Results of the test may be printed. Multiple Loop ARIES®-MLX ARIES NETLink <br /> FenwaINET 8000-ML <br /> ORDERING INFORMATION <br /> MICRO MLX <br /> Addressable Contact Input Device N.O 70-417008-001 PEGAsys* <br /> Addressable Contact Input Device N.O, 70-417018-001 FenwaINET 2000* <br /> non-silicone <br /> * FACUs running software revision 82.4 are compatibility-tested but <br /> Addressable Contact Input Device N.C. 70-417008-002 not agency listed with the device(s)in this data sheet. <br /> Package of 10 End-of-Line Resistors 70-411001-005 EXPORT INFORMATION(USA) <br /> Jurisdiction:EAR <br /> Kidde,SmartOne and ARIES are registered trademarks of Kidde-Fenwal,Inc.,or US ECCN:EAR99 <br /> its parents,subsidiaries or affiliates. This document contains technical data subject to the EAR. <br /> This literature is provided for informational purposes only.KIDDE-FENWAL,INC.believes this data to be accurate,but it is pub- 0AW <br /> lished and presented without any guarantee or warranty whatsoever.KIDDE-FENWAL,INC.assumes no responsibility for the ' Kidde <br /> product's suitability for a particular application.The fire suppression system design,installation,maintenance,service and the <br /> Fire Systems <br /> Iems <br /> shooting must be performed by trained,authorized Kidde Fire Systems distributors for the product to work correctly.If you need <br /> more information on this product,or if you have a particular problem or question,contact: KIDDE-FENWAL,INC.,Ashland,MA 400 Main Street <br /> 01721 USA,Telephone:(508)881-2000. Ashland,MA 01721 USA <br /> K-76-701 Rev AC ©2020 Kidde-Fenwal Inc. Tel:508.881.2000 <br /> www.kiddefiresystems.com <br />