3003 W CASINO RD 2025 BLDG 40-53 Plans 2025-08-19
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-53
>
Plans
>
3003 W CASINO RD 2025 BLDG 40-53 Plans 2025-08-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2025 12:00:53 PM
Creation date
8/19/2025 12:00:39 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-53
Permit
FA2501-007
Year
2025
Notes
MONITOR WF AND TAMPER SWITCH WITH EXISTING FIRE ALARM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SmartOneOj Kidde <br /> Addressable Contact Input Device Fire Systems <br /> Effective: May 2020 <br /> K-76-701 <br /> FEATURES <br /> • Monitors N.O. or N.C. Unpowered Contacts • Class B Initiating Device Circuit <br /> • Full Digital Communications • Maximum 100 Ohm Loop Resistance(both conductors) <br /> • Remote LED Output • UL Listed, ULC Listed <br /> • Alarm Test from Control Unit Keypad • FM Approved <br /> DESCRIPTION <br /> The SmartOne® Addressable Contact Input Device (AI) is an rMONITORR.,.mo <br /> MODELAl <br /> intelligent field device with its own microprocessor, memory and electronics necessary to interface N.O. or N.C. unpoweredcontacts to Kidde® intelligent control units. All of the electronics are contained in a high-impact polymer case, creating a very <br /> small and durable device for installation.A silicone-free version is <br /> available for applications where silicone is not desired. <br /> Two types of Al's are available: an AI/NC for interfacing to nor- SPECIFICATIONS <br /> mally-closed devices and an AI/NO for interfacing to normally- IDC Wiring Style:Wired as NFPA 72 Class B <br /> open devices. The Al may be located up to 3,500 feet from the Input Voltage: 24 VDC nominal <br /> monitored device with#18 AWG wiring. An end-of-line-resistor is Standby Current:580 IJA Max <br /> required for supervision of the wiring to the device. Alarm Current: 580 pA Max <br /> FIELD PROGRAMMING Max. Circuit Resistance: 100 Ohm(50 Ohm to conductor) <br /> System address, owner location message and reporting type are Operating Environment:-31 to 151°F(-35 to 66°C)at 0 to 95% RH <br /> programmable via the compatible control unit configuration soft- LED Pulse Modes: <br /> ware program. The system address is a 3-digit number that Normal: 9 second interval <br /> uniquely identifies each device. The owner location message is a Trouble: LED is off <br /> 40-character, alpha numeric message that describes the location Alarm: 2 second interval <br /> of the device. The reporting type is assigned to the Al depending Acceptable Wire Size: 14, 16, 18 AWG <br /> on the functionality of the device being monitored. The Al can be mounted in a North American 2-1/2-in. (64 mm)deep, <br /> SUPERVISION 1-gang box or standard 4-in.square box, 1-1/2-in.(38 mm)deep with <br /> cover. <br /> The Al continuously monitors the integrity of the following: <br /> COMPATIBLE CONTROL UNITS <br /> • Continuity of supervised wiring <br /> • Power/Communications circuit voltage Fire Alarm Current Legacy <br /> • Internal power supply Control Unit Product Product <br /> • Memory data (FACU)Type <br /> • Faulty entering of data into Al memory Single Loop ARIES®-SLX ARIES <br /> STATUS LED FenwaINET'"6000 <br /> A remote status LED may be connected to the Al. MICRO SLX <br /> PEGAsys"* <br /> Any Aor all RM TEST <br /> can be tested by command from the compatible FenwaINET 2000* <br /> control unit. Results of the test may be printed. Multiple Loop ARIES®-MLX ARIES NETLink <br /> FenwaINET 8000-ML <br /> ORDERING INFORMATION <br /> MICRO MLX <br /> Addressable Contact Input Device N.O 70-417008-001 PEGAsys* <br /> Addressable Contact Input Device N.O, 70-417018-001 FenwaINET 2000* <br /> non-silicone <br /> * FACUs running software revision 82.4 are compatibility-tested but <br /> Addressable Contact Input Device N.C. 70-417008-002 not agency listed with the device(s)in this data sheet. <br /> Package of 10 End-of-Line Resistors 70-411001-005 EXPORT INFORMATION(USA) <br /> Jurisdiction:EAR <br /> Kidde,SmartOne and ARIES are registered trademarks of Kidde-Fenwal,Inc.,or US ECCN:EAR99 <br /> its parents,subsidiaries or affiliates. This document contains technical data subject to the EAR. <br /> This literature is provided for informational purposes only.KIDDE-FENWAL,INC.believes this data to be accurate,but it is pub- 0AW <br /> lished and presented without any guarantee or warranty whatsoever.KIDDE-FENWAL,INC.assumes no responsibility for the ' Kidde <br /> product's suitability for a particular application.The fire suppression system design,installation,maintenance,service and the <br /> Fire Systems <br /> Iems <br /> shooting must be performed by trained,authorized Kidde Fire Systems distributors for the product to work correctly.If you need <br /> more information on this product,or if you have a particular problem or question,contact: KIDDE-FENWAL,INC.,Ashland,MA 400 Main Street <br /> 01721 USA,Telephone:(508)881-2000. Ashland,MA 01721 USA <br /> K-76-701 Rev AC ©2020 Kidde-Fenwal Inc. Tel:508.881.2000 <br /> www.kiddefiresystems.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.