Laserfiche WebLink
Seaway Commercial Center Subsurface Exploration,Geologic Hazard, <br /> 7007 Seaway Boulevard and Geotechnical Engineering Evaluation <br /> Everett, Washington Design Recommendations <br /> 10.4 Structural Fill Testing <br /> The contractor should note that any proposed fill soils must be evaluated by AESI prior to their <br /> use in fills. This would involve providing us with a sample of the material at least 3 business <br /> days in advance to perform a Proctor test to determine its field compaction standard. <br /> A representative from our firm should observe the stripped subgrade and be present during <br /> placement of structural fill to document the work and perform a representative number of <br /> in-place density tests. In this way, the adequacy of the earthwork may be evaluated as filling <br /> progresses and problem areas may be corrected at that time. It is important to understand that <br /> taking random compaction tests on a part-time basis will not assure uniformity or acceptable <br /> performance of a fill. As such, we are available to aid the owner in developing a suitable <br /> monitoring and testing frequency. <br /> 11.0 FOUNDATIONS <br /> Spread footings may be used for building support when founded either directly on the medium <br /> dense to dense native sediments (lodgement till and/or ice-contact deposits) or on compacted <br /> structural fill placed over the native sediments. The existing topsoil and near-surface zones of <br /> loose weathered lodgement till are not considered suitable for foundation support due to its <br /> potential for excessive settlements. When topsoil or loose native sediments are encountered <br /> during footing excavation, we recommend undercutting to medium dense to dense native soils <br /> and replacing with structural fill compacted to 95 percent of the modified Proctor maximum dry <br /> density. <br /> 11.1 Allowable Soil Bearing Pressure <br /> Based on the current building FFE of 522 feet, we anticipate that the bottom of footing <br /> excavations will extend to about elevation 519 feet. Therefore, we anticipate the footings will <br /> bear on structural fill within the northern half of the building footprint, medium dense native <br /> sediments near the center of the building, and dense native sediments within the southern <br /> portion of the building. <br /> For footings founded either directly on the medium dense native sediments or on compacted <br /> structural fill placed over the native sediments, we recommend that an allowable bearing <br /> pressure of 3,000 pounds per square foot (psf) be used for design purposes. A higher allowable <br /> bearing pressure of 6,000 psf may be used for footings bearing on dense native sediments.The <br /> zone of foundation bearing soils suitable for 3,000 psf loading are expected to be encountered <br /> within the northern half of the site where structural fill is required to achieve final grade and <br /> within at-grade areas underlain by medium dense ice-contact deposits or weathered till. The <br /> zone of foundation bearing soils suitable for 6,000 psf loading are expected to be encountered <br /> within the southern portion of the site where the proposed grading requires approximately 5 to <br /> December 17,2021 ASSOCIATED EARTH SCIENCES,INC. <br /> PEL/Id-20200319E001-002 Page 13 <br />