GENERAL STRUCTURAL NOTES <br /> (The following apply unless shown otherwise on the plans) <br /> CRITERIA <br /> 1. ALL MATERIALS WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE <br /> 2021 INTERNATIONAL BUILDING CODE (IBC) INCLUDING WASHINGTON STATE MODIFICATIONS. <br /> 2. DESIGN LOADING CRITERIA <br /> SNOW LOAD <br /> ROOF SNOW LOAD, Pr= 25 PSF <br /> IMPORTANCE FACTOR, Is= 1.0 <br /> EXPOSURE FACTOR, C.= 1.0 <br /> THERMAL FACTOR, Cc= 1.0 <br /> SLOPED ROOF FACTOR, Cs= 1.0 <br /> FLOOR LIVE LOAD (RESIDENTIAL) 40 PSF <br /> WIND PARAMETERS BASIC WIND SPEED = 110 MPH <br /> IMPORTANCE FACTOR, IW= 1.0 <br /> RISK CATEGORY = II <br /> TOPOGRAPHIC FACTOR, KZt = 1.0 <br /> EXPOSURE CATEGORY = B <br /> INTERNAL PRESSURE <br /> COEFFICIENT, (GCpi)= 0.18/-0.18 <br /> EARTHQUAKE DESIGN PERAMETERS Ss= 1.206 <br /> Sds = 0.965 <br /> S,= 0.429 <br /> Sd, = NULL <br /> IMPORTANCE FACTOR, le= 1.0 <br /> SITE CLASS D <br /> SEISMIC DESIGN CATEGORY= D <br /> RISK CATEGORY = II <br /> 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. <br /> CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY <br />