My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1009 COLBY AVE 2024 Plans 2025-08-19
>
Address Records
>
COLBY AVE
>
1009
>
Plans
>
1009 COLBY AVE 2024 Plans 2025-08-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2025 1:32:04 PM
Creation date
8/19/2025 1:30:21 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1009
Permit
B2407-051
Year
2024
Notes
New Kitchen and Bathroom on the Main Floor
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
19. WOOD FASTENERS: <br /> A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: <br /> SIZE LENGTH DIAMETER <br /> 6d 2" 0.113" <br /> 8d 2-1/2" 0.131" <br /> 10d 3" 0.148" <br /> 12d 3-1/4" 0.148" <br /> 16d 3-1/2" 0.162" <br /> DESIGN IS BASED ON COMMON STEEL WIRE NAILS MEETING THE REQUIREMENTS OF ASTM F1667. USE OF ALTERNATE <br /> FASTENERS MUST BE SUBMITTED FOR REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER PRIOR TO THE START OF <br /> CONSTRUCTION. <br /> B. NAILS— PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING <br /> WITH NO COUNTERSINKING PERMITTED. <br /> WOOD FRAMING NOTES—THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: <br /> A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE <br /> INTERNATIONAL BUILDING CODE. MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.10.1 OF <br /> THE INTERNATIONAL BUILDING CODE. UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE AS SPECIFIED ABOVE. <br /> COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE <br /> WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. INSTALLATION OF BOLTS <br /> AND LAG SCREWS SHALL CONFORM TO SECTIONS 12.1.3 AND 12.1.4 OF THE 2018 NATIONAL DESIGN SPECIFICATION FOR <br /> WOOD CONSTRUCTION. NATURALLY DURABLE OR PRESSURE TREATED WOOD SHALL BE PROVIDED WHERE REQUIRED BY <br /> SECTION 2304.12 OF THE INTERNATIONAL BUILDING CODE. <br /> B. WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2X6 AT 16" O.C. TWO STUDS MINIMUM <br /> SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS. TWO 2 x 8 HEADERS SHALL BE <br /> PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED AND SHALL BEAR FULLY ON A MINIMUM OF TWO STUDS. SOLID <br /> BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE SOLID <br /> BLOCKING BETWEEN STUDS AT MID-HEIGHT OF ALL STUD WALLS OVER 10, IN HEIGHT. <br /> STUDS MAY BE NOTCHED, CUT, OR PENETRATED WITH ROUND BORED HOLES AS FOLLOWS: <br /> STUD SIZE MAXIMUM NOTCH /CUT MAXIMUM BORED HOLE <br /> 2X4 7/8" 1-3/8" <br />
The URL can be used to link to this page
Your browser does not support the video tag.