POS & COD ISOLATED GROUND/DEDOCATED CIRCUIT m <br /> SOLID#12 AWG KEY NOTES <br /> CEILING 4•SHOWS CONNECTION/BONDING POINT OPPER CONDUCTORSONLY. 8 THIS IS THE ONLY POINT WHERE THE ISOLATED 2 <br /> EQUIPMENT GROUNDING CONDUCTOR SHALL BE O <br /> CONNECTED TO THE BUILDING'S GROUNDING <br /> CONTRACTOR TO UTILIZE SYSTEM. o cn <br /> CONDUCTORS PROVIDED <br /> WITH RETROFIT POWER BASE SERVICE ENTRANCE 3 PANEL CP COMPUTER 9 ❑ m B,2 SEE BUILDING GROUNDING DETAIL THIS SHEET. o: U1 o; <br /> KIT TO POWER (TYPICALLY MDP) ONLY <br /> RECEPTACLES WITHIN BASE. A B C 1-1/2" METAL CONDUIT: 4-#1 CU + 1-#6 CU <br /> REFER TO RETROFIT KIT <br /> A B C BLK 10EE EQUIP OLD + 1- 4 CU ISOLATED GND. W <br /> INSTRUCTIONS. SIDE BY SIDE OR STACKED LTZA-3 RED �'jr <br /> cRN vLw STRI ❑ a o <br /> CASH HANDLER 1LI1 RN METAL JUNCTION 11 4 ALL ISOLATED GROUND/ DEDICATED CIRCUIT o, <br /> WHT RECEPTACLE COVER PLATES SHALL BE ORANGE <br /> 4 AWG GRN YLw STRBOX HUBBELL PJ7C0 (SINGLE), PJSCO (ONE DUPLEX) <br /> GRN 12 OR P182C0 (TWO DUPLEX) MARKED "COMPUTER d, <br /> KIOSK RETROFIT POWER BASE KIT. 5 ONLY". W N N <br /> KIT REPLACES EXISTING KIOSK 13 <br /> LEGS AND BASE. KIT INCLUDES - GRN YLW METAL CONDUIT SHALL CONTAIN ONLY P.O.S. p N N <br /> RECEPTACLES FOR CASH 6 CIRCUIT CONDUCTORS (DEDICATED CIRCUIT). ONLY o 4D 0 <br /> HANDLERS, WIRED BY CONTRACTOR FLOOR N USE RIGID NON-METALLIC CONDUIT BELOW GRADE <br /> WHEN REQUIRED BY LOCAL CODE. a a 7 <br /> g EQUIPMENT GROUNDING BONDING CONDUCTOR <br /> (TYPICAL) Professional of Record: <br /> NOTES: <br /> 1. THIS EXAMPLE IS FOR A SIDE BY SIDE CASH HANDLER THAT DOES ❑ ISOLATED GROUND BUS, ELECTRICALLY INSULATED PM <br /> NOT HAVE A GC WALL BEHIND IT AND IS NEXT TO A KIOSK. IT IS ALSO 7 FROM PANEL ENCLOSURE USED TO TERMINATE <br /> INTENDED FOR ALL STACKED CASH HANDLERS. ONLY ISOLATED EQUIPMENT GROUNDING <br /> 2. EACH SIDE BY SIDE CASH HANDLER UTILIZES 3 PLUGS AND ADDS 4.4 CONDUCTORS. <br /> AMPS OF LOAD TO THE KIOSK CIRCUIT. NOTES ALL CONDUCTORS SHALL BE SOLID COPPER AND DESIGN <br /> 3. EACH STACKED CASH HANDLER UTILIZED 2 PLUGS AND ADDS 3.6 TERMINATED TO THEIR APPROPRIATE TERMINAL <br /> AMPS OF LOAD TO THE KIOSK CIRCUIT. 1. ALL P.O.S. EQUIPMENT 5. EC SHALL DETERMINE CORRECT POLARITY AT SCREWS BY WRAPPING THE CONDUCTOR Architectural <br /> 4. ONLY 1 SIDE BY SIDE CAN BE CONNECTED TO A KIOSK, HOWEVER (COMPUTERS,PRINTERS,MONITORS, KVS, MODEM, RECEPTACLE. COMPLETELY AROUND THE SCREW BARREL AND Solutions Group <br /> TWO STACKED UNITS CAN BE CONNECTED. REFER TO DECOR PLANS HUB & COD) SHALL BE POWERED FROM THE TIGHTENING THE SCREW PER MANUFACTURER'S <br /> FOR EXACT CONFIGURATIONS. COMPUTER PANEL. 6. EC SHALL DETERMINE THAT SUBPANEL CP TORQUE SPECIFICATIONS. 1940140TH AVEW <br /> DOES NOT CONTAIN ANY ILLEGAL NEUTRAL TO SUITE 420 <br /> ALL OTHER COMPUTER/DIGITAL EQUIPMENT GROUND BONDS. ISOLATED GROUND RECEPTACLE LYNNWOOD,WA 98036 <br /> �� TYP. CASH HANDLER POWER DETAIL SHALL BE POWERED FROM PHASE "A" IN THE1fl HUBBELL-IG4700,IG471OJG5262 OR IG5261. SEE LAMES 1REARE <br /> COMPUTER PANEL. 7. PANEL CP SHALL ONLY BE USED TO POWER ROUGH IN SCHEDULE FOR THE APPROPRIATE vHONE:(425)401 <br /> E1.3 FOR REFERENCE ONLY SENSITIVE ELECTRONIC EQUIPMENT, AS RECEPTACLE TO USE. EMwcJrer IR MDOINCCOM <br /> 2. ISOLATED GROUND INSTALLATION SHALL COMPLY OUTLINED IN NOTE #1. IT SHALL NOT BE USED 10 <br /> WITH THE REQUIREMENTS OF NEC SECTION TO POWER ANY OTHER LOADS. ISOLATED GREEN GROUND SCREW. <br /> 250. ISOLATED EQUIPMENT GROUNDING CONDUCTOR (GRN <br /> 8. IT IS A SAFETY HAZARD AND AN NEC VIOLATION <br /> 02 11 <br /> 3. EACH 20 AMP CIRCUIT SHALL HAVE IT'S OWN FOR THE POS SYSTEM TO HAVE ITS OWN W/YLW STRIP) <br /> ISOLATED EQUIPMENT GROUNDING CONDUCTOR. INDEPENDENT GROUNDING ROD. IF AN <br /> INDEPENDENT GROUND ROD IS FOUND FOR 12 NEUTRAL CONDUCTOR TERMINATED ON SILVER <br /> 4. ENTIRE GROUNDING SYSTEM SHALL COMPLY THE POS SYSTEM, IT SHALL BE BONDED TO SCREW. <br /> WITH NEC ARTICLE 250 AND MCDONALD's THE BUILDING GROUNDING SYSTEM. 13 PHASE CONDUCTOR TERMINATED ON BRASS SCREW <br /> BUILDING GROUNDING DETAIL. <br /> 5'-O" CEILING ° �S A Ye�9°Oo <br /> EQUAL EQUAL C,I P OF(�Niyc'A��o <br /> MI 4c <br /> O SIDE BY SIDE CASH HANDLER <br /> Seal <br /> N CONTRACTOR TO PROVIDE QUAD IG5262 GROUND RECEPTACLE. � ° <br /> a ° ceo�o'o <br /> CONTRACTOR TO PROVIDE JUNCTION BOX WITH 1" CONDUIT ROUTED TO V .8-$'1'§ <br /> ABOVE ACCESSIBLE CEILING FOR DATA CABLES 0 _ J Q85� <br /> N r-1o„ - J U <br /> FLOOR °u o <br /> `°g3jE•6p <br /> NOTES: 'R=n o <br /> 3�08 <br /> 1. THIS EXAMPLE IS FOR A SIDE BY SIDE CASH HANDLER WITH THE POWER � �REAR OF OF THE UNIT FACING A FULL HEIGHT GC BUILT WALL. RECEPTACLES o c, <br /> 2. EACH SIDE BY SIDE CASH HANDLER UTILIZES 3 PLUGS AND ADDS 4.4 O =-6o 8o 5 <br /> AMPS OF LOAD. <br /> EQUAL EQUAL N o c °E 'R.o <br /> 3 TYP. CASH HANDLER POWER DETAIL W REAR TO WALL .o�c,sa; <br /> E1.3 FOR REFERENCE ONLY a =v ia° <br /> MEDIA PLAYER INSTALLED BEHIND ® ® I.h sl8B <br /> z SCREEN. REFER TO MANUFACTURER'S <br /> 'z INSTALLATION INSTRUCTIONS ij o <br /> x � <br /> CABLE ENTRY OPENING 14"X14" -BOX(S)FOR DATA <br /> a <br /> ° DATA CABLE CONTRACTOR TO PROVIDE IG5262 POWER RECEPTACLE FLUSH ON CEILING CONTRACTOR TO PROVIDE IG5262 RECEPTACLE w <br /> MODULAR COUNTER RACEWAY TYP. <br /> o AND J-BOX WITH 1" CONDUIT TO ABOVE 1 o a <br /> CEILING CEILING WITH BUSHINGS FOR DATA CABLES. E1.3 FOR REFERENCE ONLY <br /> SUPPLY WITH GROMMETED OPENING IN COVER m o r <br /> GROMMIT FOR POWER CORD TO EXIT <br /> PLATE AT LOCATION SHOWN o o <br /> N o 0 <br /> SYMBOL CATALOG# DESCRIPTION <br /> o ® HBLALU57DR&IG4700 RECEPTACLE COVERPLATE WITH ORANGE, <br /> TWIST LOCK,ISOLATED GROUND <br /> 0 <br /> DUPLEX RECEPTACLE <br /> U FLOOR OO ANDHBILALJ57DR262 &5-20R FOR BAKED GOODS RECEPTACLE RECEPTACLE <br /> LATE WITH STRAIGHT <br /> NOTES: AND IG5262 FOR CASH BLADE RECEPTACLE <br /> ` MEDIA PLAYER INSTALLED BEHIND SCREEN. REFER TO MANUFACTURER'S 1. THIS EXAMPLE IS FOR A WALL MOUNTED DIGITAL MERCHANDISER. ® HBLAws7LPB coMMUNlcnnoNs covERPUTE <br /> 0 INSTALLATION IN <br /> O HBLALU762OB02M290 2'SECTION OF RACEWAY.INCLUDES <br /> 3 <br /> COUPLERS 3 <br /> F CEILING IS ABOVE 10' TALL, PROVIDE IG5262 RECEPTACLE AND J-BOX o HBLALu7620B03M290 3•SECTION OF RACEWAY.INCLUDES <br /> DIGITAL MERCHANDISER POWER DETAIL COUPLERS <br /> WITH 1" CONDUIT TO ABOVE CEILING FOR DATA CABLES AT LOCATION 5 HBLALu761OB2M2 SERVICE ENTRANCE FILLING&BUSHING r� <br /> w SHOWN FOR REFERENCE ONLY <br /> FOR DATA CABLES (�I <br /> ® HBLALU7610B BLANK END FITTING 3 <br /> hf N/A HBLALJ5701 COUPLER(INCLUDED WITH RACEWAY z Q <br /> NOTES: FLOOR SECTION) Ul <br /> 1. DIGITAL MERCHANDISER CHANNELS ARE DESIGNED TO REACH UP TO A N A HBLALJ5709 I GROUND ADAPTER z <br /> 10' CEILING. IF CEILING IS TALLER, EXTENDER KIT CAN BE ORDERED TO NOTES: N w <br /> REACH 15'. 1. REFER TO SERVICE POD MANUFACTURER INSTRUCTIONS FOR EXACT PLACEMENT ELL z <br /> OF RACEWAY Z0 <br /> o <br /> O aY <br /> 2. RACEWAY AND RECEPTACLES TO BE PROVIDED WITH SERVICE POD, INSTALLED BY w � W 4� FREESTANDING MERC POWER DETAIL coNTRACTOR. _ > o a o <br /> a E1 3 FOR REFERENCE ONLY 3. DETAIL SHOWN IS A TYPICAL CONFIGURATION ONLY. SITE SPECIFICS MIGHT CAUSE h W o Un <br /> d DEVIATIONS. I�L� <br /> e 4. PART NUMBERS SHOWN REFLECT HUBBELL, SOME SUPPIERS MAY USE WIREMOLE Ir <br /> EQUIVALENT. = LLLLLL u 3 U <br /> COUNTER DETAILS <br /> 16 <br /> City of Everett Permit Services <br /> EVERETT Reviewed for Permit 11/14/2024 <br />