My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7920 EVERGREEN WAY 2024 Plans 2025-08-19
>
Address Records
>
EVERGREEN WAY
>
7920
>
Plans
>
7920 EVERGREEN WAY 2024 Plans 2025-08-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2025 2:24:08 PM
Creation date
8/19/2025 2:22:47 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7920
Permit
B2404-061
PW2404-062
Year
2024
Notes
NEW INTERIOR PARTITIONS, UPDATED SUSPENDED CEILING, ADA. PARKING LOT IMPROVEMENTS FOR MCDONALDS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POS & COD ISOLATED GROUND/DEDOCATED CIRCUIT m <br /> SOLID#12 AWG KEY NOTES <br /> CEILING 4•SHOWS CONNECTION/BONDING POINT OPPER CONDUCTORSONLY. 8 THIS IS THE ONLY POINT WHERE THE ISOLATED 2 <br /> EQUIPMENT GROUNDING CONDUCTOR SHALL BE O <br /> CONNECTED TO THE BUILDING'S GROUNDING <br /> CONTRACTOR TO UTILIZE SYSTEM. o cn <br /> CONDUCTORS PROVIDED <br /> WITH RETROFIT POWER BASE SERVICE ENTRANCE 3 PANEL CP COMPUTER 9 ❑ m B,2 SEE BUILDING GROUNDING DETAIL THIS SHEET. o: U1 o; <br /> KIT TO POWER (TYPICALLY MDP) ONLY <br /> RECEPTACLES WITHIN BASE. A B C 1-1/2" METAL CONDUIT: 4-#1 CU + 1-#6 CU <br /> REFER TO RETROFIT KIT <br /> A B C BLK 10EE EQUIP OLD + 1- 4 CU ISOLATED GND. W <br /> INSTRUCTIONS. SIDE BY SIDE OR STACKED LTZA-3 RED �'jr <br /> cRN vLw STRI ❑ a o <br /> CASH HANDLER 1LI1 RN METAL JUNCTION 11 4 ALL ISOLATED GROUND/ DEDICATED CIRCUIT o, <br /> WHT RECEPTACLE COVER PLATES SHALL BE ORANGE <br /> 4 AWG GRN YLw STRBOX HUBBELL PJ7C0 (SINGLE), PJSCO (ONE DUPLEX) <br /> GRN 12 OR P182C0 (TWO DUPLEX) MARKED "COMPUTER d, <br /> KIOSK RETROFIT POWER BASE KIT. 5 ONLY". W N N <br /> KIT REPLACES EXISTING KIOSK 13 <br /> LEGS AND BASE. KIT INCLUDES - GRN YLW METAL CONDUIT SHALL CONTAIN ONLY P.O.S. p N N <br /> RECEPTACLES FOR CASH 6 CIRCUIT CONDUCTORS (DEDICATED CIRCUIT). ONLY o 4D 0 <br /> HANDLERS, WIRED BY CONTRACTOR FLOOR N USE RIGID NON-METALLIC CONDUIT BELOW GRADE <br /> WHEN REQUIRED BY LOCAL CODE. a a 7 <br /> g EQUIPMENT GROUNDING BONDING CONDUCTOR <br /> (TYPICAL) Professional of Record: <br /> NOTES: <br /> 1. THIS EXAMPLE IS FOR A SIDE BY SIDE CASH HANDLER THAT DOES ❑ ISOLATED GROUND BUS, ELECTRICALLY INSULATED PM <br /> NOT HAVE A GC WALL BEHIND IT AND IS NEXT TO A KIOSK. IT IS ALSO 7 FROM PANEL ENCLOSURE USED TO TERMINATE <br /> INTENDED FOR ALL STACKED CASH HANDLERS. ONLY ISOLATED EQUIPMENT GROUNDING <br /> 2. EACH SIDE BY SIDE CASH HANDLER UTILIZES 3 PLUGS AND ADDS 4.4 CONDUCTORS. <br /> AMPS OF LOAD TO THE KIOSK CIRCUIT. NOTES ALL CONDUCTORS SHALL BE SOLID COPPER AND DESIGN <br /> 3. EACH STACKED CASH HANDLER UTILIZED 2 PLUGS AND ADDS 3.6 TERMINATED TO THEIR APPROPRIATE TERMINAL <br /> AMPS OF LOAD TO THE KIOSK CIRCUIT. 1. ALL P.O.S. EQUIPMENT 5. EC SHALL DETERMINE CORRECT POLARITY AT SCREWS BY WRAPPING THE CONDUCTOR Architectural <br /> 4. ONLY 1 SIDE BY SIDE CAN BE CONNECTED TO A KIOSK, HOWEVER (COMPUTERS,PRINTERS,MONITORS, KVS, MODEM, RECEPTACLE. COMPLETELY AROUND THE SCREW BARREL AND Solutions Group <br /> TWO STACKED UNITS CAN BE CONNECTED. REFER TO DECOR PLANS HUB & COD) SHALL BE POWERED FROM THE TIGHTENING THE SCREW PER MANUFACTURER'S <br /> FOR EXACT CONFIGURATIONS. COMPUTER PANEL. 6. EC SHALL DETERMINE THAT SUBPANEL CP TORQUE SPECIFICATIONS. 1940140TH AVEW <br /> DOES NOT CONTAIN ANY ILLEGAL NEUTRAL TO SUITE 420 <br /> ALL OTHER COMPUTER/DIGITAL EQUIPMENT GROUND BONDS. ISOLATED GROUND RECEPTACLE LYNNWOOD,WA 98036 <br /> �� TYP. CASH HANDLER POWER DETAIL SHALL BE POWERED FROM PHASE "A" IN THE1fl HUBBELL-IG4700,IG471OJG5262 OR IG5261. SEE LAMES 1REARE <br /> COMPUTER PANEL. 7. PANEL CP SHALL ONLY BE USED TO POWER ROUGH IN SCHEDULE FOR THE APPROPRIATE vHONE:(425)401 <br /> E1.3 FOR REFERENCE ONLY SENSITIVE ELECTRONIC EQUIPMENT, AS RECEPTACLE TO USE. EMwcJrer IR MDOINCCOM <br /> 2. ISOLATED GROUND INSTALLATION SHALL COMPLY OUTLINED IN NOTE #1. IT SHALL NOT BE USED 10 <br /> WITH THE REQUIREMENTS OF NEC SECTION TO POWER ANY OTHER LOADS. ISOLATED GREEN GROUND SCREW. <br /> 250. ISOLATED EQUIPMENT GROUNDING CONDUCTOR (GRN <br /> 8. IT IS A SAFETY HAZARD AND AN NEC VIOLATION <br /> 02 11 <br /> 3. EACH 20 AMP CIRCUIT SHALL HAVE IT'S OWN FOR THE POS SYSTEM TO HAVE ITS OWN W/YLW STRIP) <br /> ISOLATED EQUIPMENT GROUNDING CONDUCTOR. INDEPENDENT GROUNDING ROD. IF AN <br /> INDEPENDENT GROUND ROD IS FOUND FOR 12 NEUTRAL CONDUCTOR TERMINATED ON SILVER <br /> 4. ENTIRE GROUNDING SYSTEM SHALL COMPLY THE POS SYSTEM, IT SHALL BE BONDED TO SCREW. <br /> WITH NEC ARTICLE 250 AND MCDONALD's THE BUILDING GROUNDING SYSTEM. 13 PHASE CONDUCTOR TERMINATED ON BRASS SCREW <br /> BUILDING GROUNDING DETAIL. <br /> 5'-O" CEILING ° �S A Ye�9°Oo <br /> EQUAL EQUAL C,I P OF(�Niyc'A��o <br /> MI 4c <br /> O SIDE BY SIDE CASH HANDLER <br /> Seal <br /> N CONTRACTOR TO PROVIDE QUAD IG5262 GROUND RECEPTACLE. � ° <br /> a ° ceo�o'o <br /> CONTRACTOR TO PROVIDE JUNCTION BOX WITH 1" CONDUIT ROUTED TO V .8-$'1'§ <br /> ABOVE ACCESSIBLE CEILING FOR DATA CABLES 0 _ J Q85� <br /> N r-1o„ - J U <br /> FLOOR °u o <br /> `°g3jE•6p <br /> NOTES: 'R=n o <br /> 3�08 <br /> 1. THIS EXAMPLE IS FOR A SIDE BY SIDE CASH HANDLER WITH THE POWER � �REAR OF OF THE UNIT FACING A FULL HEIGHT GC BUILT WALL. RECEPTACLES o c, <br /> 2. EACH SIDE BY SIDE CASH HANDLER UTILIZES 3 PLUGS AND ADDS 4.4 O =-6o 8o 5 <br /> AMPS OF LOAD. <br /> EQUAL EQUAL N o c °E 'R.o <br /> 3 TYP. CASH HANDLER POWER DETAIL W REAR TO WALL .o�c,sa; <br /> E1.3 FOR REFERENCE ONLY a =v ia° <br /> MEDIA PLAYER INSTALLED BEHIND ® ® I.h sl8B <br /> z SCREEN. REFER TO MANUFACTURER'S <br /> 'z INSTALLATION INSTRUCTIONS ij o <br /> x � <br /> CABLE ENTRY OPENING 14"X14" -BOX(S)FOR DATA <br /> a <br /> ° DATA CABLE CONTRACTOR TO PROVIDE IG5262 POWER RECEPTACLE FLUSH ON CEILING CONTRACTOR TO PROVIDE IG5262 RECEPTACLE w <br /> MODULAR COUNTER RACEWAY TYP. <br /> o AND J-BOX WITH 1" CONDUIT TO ABOVE 1 o a <br /> CEILING CEILING WITH BUSHINGS FOR DATA CABLES. E1.3 FOR REFERENCE ONLY <br /> SUPPLY WITH GROMMETED OPENING IN COVER m o r <br /> GROMMIT FOR POWER CORD TO EXIT <br /> PLATE AT LOCATION SHOWN o o <br /> N o 0 <br /> SYMBOL CATALOG# DESCRIPTION <br /> o ® HBLALU57DR&IG4700 RECEPTACLE COVERPLATE WITH ORANGE, <br /> TWIST LOCK,ISOLATED GROUND <br /> 0 <br /> DUPLEX RECEPTACLE <br /> U FLOOR OO ANDHBILALJ57DR262 &5-20R FOR BAKED GOODS RECEPTACLE RECEPTACLE <br /> LATE WITH STRAIGHT <br /> NOTES: AND IG5262 FOR CASH BLADE RECEPTACLE <br /> ` MEDIA PLAYER INSTALLED BEHIND SCREEN. REFER TO MANUFACTURER'S 1. THIS EXAMPLE IS FOR A WALL MOUNTED DIGITAL MERCHANDISER. ® HBLAws7LPB coMMUNlcnnoNs covERPUTE <br /> 0 INSTALLATION IN <br /> O HBLALU762OB02M290 2'SECTION OF RACEWAY.INCLUDES <br /> 3 <br /> COUPLERS 3 <br /> F CEILING IS ABOVE 10' TALL, PROVIDE IG5262 RECEPTACLE AND J-BOX o HBLALu7620B03M290 3•SECTION OF RACEWAY.INCLUDES <br /> DIGITAL MERCHANDISER POWER DETAIL COUPLERS <br /> WITH 1" CONDUIT TO ABOVE CEILING FOR DATA CABLES AT LOCATION 5 HBLALu761OB2M2 SERVICE ENTRANCE FILLING&BUSHING r� <br /> w SHOWN FOR REFERENCE ONLY <br /> FOR DATA CABLES (�I <br /> ® HBLALU7610B BLANK END FITTING 3 <br /> hf N/A HBLALJ5701 COUPLER(INCLUDED WITH RACEWAY z Q <br /> NOTES: FLOOR SECTION) Ul <br /> 1. DIGITAL MERCHANDISER CHANNELS ARE DESIGNED TO REACH UP TO A N A HBLALJ5709 I GROUND ADAPTER z <br /> 10' CEILING. IF CEILING IS TALLER, EXTENDER KIT CAN BE ORDERED TO NOTES: N w <br /> REACH 15'. 1. REFER TO SERVICE POD MANUFACTURER INSTRUCTIONS FOR EXACT PLACEMENT ELL z <br /> OF RACEWAY Z0 <br /> o <br /> O aY <br /> 2. RACEWAY AND RECEPTACLES TO BE PROVIDED WITH SERVICE POD, INSTALLED BY w � W 4� FREESTANDING MERC POWER DETAIL coNTRACTOR. _ > o a o <br /> a E1 3 FOR REFERENCE ONLY 3. DETAIL SHOWN IS A TYPICAL CONFIGURATION ONLY. SITE SPECIFICS MIGHT CAUSE h W o Un <br /> d DEVIATIONS. I�L� <br /> e 4. PART NUMBERS SHOWN REFLECT HUBBELL, SOME SUPPIERS MAY USE WIREMOLE Ir <br /> EQUIVALENT. = LLLLLL u 3 U <br /> COUNTER DETAILS <br /> 16 <br /> City of Everett Permit Services <br /> EVERETT Reviewed for Permit 11/14/2024 <br />