&NAUTOCALL <br /> 4007ES Hybrid, Fire Detection and Control Unit with Addressable and/or Conventional Initiation <br /> Battery compartment(bottom)accepts two batteries,up to 18 Ah,to CO sensor bases <br /> be mounted within the cabinet without interfering with module space; CO sensor bases combine an electrolytic CO sensing module with a <br /> charger capacity is up to 33 Ah;for information about batteries greater TrueAlarm analog sensor to provide a single multiple sensing assembly <br /> than 18 Ah and external battery cabinets,see Module and accessories using one system address.You can enable and disable the CO sensor, <br /> selection information and you can use it in LED/Switch modes and custom control.Refer to <br /> Cabinet assembly design has been seismic tested and is certified to data sheet AC4098-0052 for more details. <br /> IBC and CBC standards as well as to ASCE 7 categories A through F, <br /> requires battery brackets,refer to data sheet AC2081-0019 for more TrueAlarm heat sensors <br /> information You can select TrueAlarm heat sensors for fixed temperature detection, <br /> Seismically compliant under the State of California Statewide Office with or without rate-of-rise detection.Utility temperature sensing is also <br /> of Housing and Development(OSHPD)Special Seismic Certification available,typically to provide freeze warnings or alert to HVAC system <br /> (SSC)program guidelines.Refer to Simplex Seismic Application Guide problems.Readings are selectable as either Fahrenheit or Celsius. <br /> 579-1213AC and Battery Brackets for Seismic Activity Applications TrueSense early fire detection <br /> AC2081-0019 for details. Multi-sensor A4098-9754 provides photoelectric and heat sensor data <br /> using a single IDNet address.The panel evaluates smoke activity,heat <br /> IDNet 2 addressable device control activity,and their combination,to provide TrueSense early detection.For <br /> The 4007ES Hybrid provides an IDNet 2 addressable initiating device more details on this operation,refer to data sheet AC4098-0024. <br /> signaling line circuit(SLC)that supervises wiring connections and the <br /> individual device communications status on the SLC.With 2-wire IDNet Diagnostics and default device type <br /> 2 SLCs,initiation,monitoring,and control devices such as manual <br /> fire alarm stations,TrueAlarm sensors,control relays,and sprinkler Sensor status <br /> waterflow switches can communicate their identity and status and TrueAlarm operation allows the FACU to automatically indicate when <br /> receive fire alarm system control.Additional addressable interface a sensor is almost dirty,dirty,and excessively dirty.The NFPA 72 <br /> modules include circuit isolators,conventional IDC zone adapters,and requirement for a test of the sensitivity range of the sensors is fulfilled <br /> interface to other system circuits such as fans,dampers,and elevator by the ability of TrueAlarm operation to maintain the sensitivity level of <br /> controls. each sensor.CO sensors track their 10 year active life status providing <br /> indicators to assist with service planning.Indicators occur at:1 year,6 <br /> IDNet 2 addressable device operation months,and end of life. <br /> Each addressable device on the IDNet 2 communication channel Modular TrueAlarm sensors <br /> is continuously interrogated for status condition such as:normal, TrueAlarm sensors use the same base and different sensor types(smoke <br /> off-normal,alarm,supervisory,or trouble.Both Class B and Class A or heat sensor)and can be easily interchanged to meet specific location <br /> operation is available.Sophisticated poll and response communication requirements.This allows intentional sensor substitution during building <br /> techniques ensure supervision integrity and allow for T-tapping of construction when conditions are temporarily dusty.Instead of covering <br /> the circuits for Class B operation.Devices with LEDs pulse the LED to smoke sensors causing them to disable,heat sensors may be installed <br /> indicate receipt of a communications poll and can be turned on steady without reprogramming the FACU.The FACU will indicate an incorrect <br /> from the panel.With addressable devices,the location and status of the sensor type,but the heat sensor will operate at a default sensitivity to <br /> connected device is monitored,logged,and displayed on the operator provide heat detection for building protection at that location. <br /> interface LCD with each device having its own 40-character custom label <br /> for precise identification. <br /> IDNet 2 addressable channel capacity <br /> TrueAlarm addressable sensor operation The 4007ES Hybrid provides an isolated output IDNet 2 SLC that <br /> Addressable initiating device communications include operation of supports up to 250 addressable monitor and control points intermixed <br /> TrueAlarm smoke and temperature sensors.Smoke sensors transmit on the same pair of wires.250 total requires two A007-9803 IDNet 2 <br /> an output value based on their smoke chamber condition and the CPU loop expansion modules. <br /> maintains a current value,peak value,and an average value for each Table 1:IDNet 2 SLC wiring specifications <br /> sensor.Status is determined by comparing the current sensor value to Specification Rating <br /> its average value.Tracking this average value as a continuously shifting 0 to <br /> reference point filters out environmental factors that cause shifts in Maximum distance from 125 4000 ft(1219 m);50 ohms <br /> sensitivity. control panel for each device 126 to <br /> load 250 2500 ft(762 m);35 ohms <br /> ° Total wire length allowed with T-taps Up to 12,500 ft(3.8 km);0.60 <br /> for Class B wiring pF <br /> Maximum capacitance between <br /> Figure 3:TrueAlarm Figure 4:TrueAlarm Photo/ IDNet 2 channels 1 NF <br /> Photo Sensor with base Heat Sensor in CO base Shielded or unshielded, <br /> Wire type and connections twisted or untwisted wire,see <br /> Programmable sensitivity note. <br /> Programmable sensitivity of each sensor is selectable at the control Terminal blocks for 18 AWG <br /> panel for different levels of smoke obscuration,shown directly in Connections to 12 AWG <br /> percent,or for specific heat detection levels.To evaluate whether the Compatibility includes:IDNet communicating devices and TrueAlarm <br /> sensitivity should be revised,the peak value is stored in memory and can sensors including QuickConnect and QuickConnect2 sensors;see data <br /> be easily read or downloaded as a report and compared to the alarm sheet AC4090-0011 for additional reference. <br /> threshold directly in percent. <br /> Note:Some applications may require shielded wiring.Review your sys- <br /> tem with your local Autocall product supplier. <br /> Page 3 AC4007-0001 Rev.20 11/2021 <br />