My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10710 EVERGREEN WAY 2025-09-11
>
Address Records
>
EVERGREEN WAY
>
10710
>
10710 EVERGREEN WAY 2025-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 8:08:21 AM
Creation date
8/19/2025 3:22:14 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10710
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
&NAUTOCALL <br /> 4007ES Hybrid, Fire Detection and Control Unit with Addressable and/or Conventional Initiation <br /> Power supply output and zone/relay module details <br /> Power supply output details <br /> RUI Communications controls up to 10 remote devices at up to 2500 ft(762 m)for single run,or 10,000 ft(3048 m)total if wiring is Class B and T- <br /> tapped;selectable as Class B or Class A <br /> Compatible RUI remote equipment includes:A4606-9202 and A4606-9205 Color Touchscreen Annunciators(up to 6 total),4100 Series 24 1/0 and <br /> LED/Switch modules,A602 Series LED/Switch and 1/0 Annunciator modules,including A602-9101 Status Command Units(SCU),and A602-9102 <br /> Remote Command Units(RCU) <br /> IDNet 2 SLC output provides electrically isolated Class B or Class A communication;standard capacity is up to 100 addressable points with expansion <br /> for up to 250 points using up to two A007-9803 IDNet 2 Loop Expansion Modules;as described in IDNet 2 addressable channel capacity <br /> 6 A output rating,including current for:special application notification appliances;IDNet devices;module currents;and auxiliary output current <br /> (battery charging,CPU,and power supply current does not subtract from the 6 A);when NACs are controlling Regulated 24 DC Appliances,total NAC <br /> current available is 3 A <br /> Four on-board Class B/Class A NACs,rated 3 A each for Special Application appliances;selectable for SmartSync horn and strobe control,or strobe <br /> synchronization;rated 2 A each for Regulated 24 DC appliances <br /> NAC EOL resistor values are selectable as: 10 kohms,3.9 kohms,4.7 kohms,5.1 kohms,5.6 kohms,or 15 kohms <br /> Battery charger is dual rate,temperature compensated,and charges up to 18 Ah sealed lead-acid batteries mounted in the battery compartment, <br /> and charges up to 33 Ah batteries mounted in an external cabinet <br /> Battery and Charger Monitoring includes battery charger status and low or depleted battery conditions;status information provided to the master <br /> controller includes analog values for:battery voltage,charger voltage and current,actual system voltage and current,and NAC current <br /> Low Battery Voltage Cutout is selectable when required(required for ULC Listing applications) <br /> 2 A Auxiliary Output(AUX/SNAC)can be selected either as resettable auxiliary power of 2 A @ 24 VDC,or selected to be a simple NAC(SNAC)for <br /> sounder base power,four-wire detector power,or door holder power <br /> Zone/relay module details <br /> Select as IDC or Relay;configure up to eight Class B IDCs,or up to four Class A IDCs;or up to eight Relay outputs rated 2 A resistive @ 30 VDC(N.O.or <br /> N.C.);or combinations of IDCs and Relays;each zone is separately configurable as an IDC or Relay output <br /> IDC Support.Each IDC supports up to 30,two-wire devices <br /> IDC EOL resistor values are selectable as:3.3 kohms,2 kohms,2.2 kohms,3.4 kohms,3.9 kohms,4.7 kohms,5.1 kohms,5.6 kohms,6.34/6.8 kohms, <br /> and 3.6 kohms+1.1 kohms;see instructions for more details <br /> Page 5 AC4007-0001 Rev.20 11/2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.