WALL CONSTRUCTION <br /> TABLE R602.3(1)-continued <br /> FASTENING SCHEDULE <br /> ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENERa.°.` SPACING AND LOCATION <br /> 16d common(3'/2"x 0.162') 16"o.c.face nail <br /> 14 Bottom plate to joist,rim joist,band joist or <br /> blocking(not at braced wall panels) 16d box(3'/2"x 0.135,),or 12"o.c.face nail <br /> 3"x 0.131"nails <br /> 3-16d box(31/2"x 0.135'�;or 3 each 16"o.c.face nail <br /> 15 Bottom plate to joist,rim joist,band joist or 2-16d common(3'/2"x 0.162'1;or 2 each 16"o.c.face nail <br /> blocking(at braced wall panel) 43"x 0.131"nails 4 each 16"o.c.face nail <br /> 4-8d box(2'/2"x 0.113 0;or <br /> 3-16d box 0/2"x 0.135'�;or <br /> 4-8d common(2'/2"x 0.13 V);or Toe nail <br /> 4-10d box(3"x 0.12g'D;or <br /> 16 Top or bottom plate to stud 4-3"x 0.131"nails <br /> 3-16d box(31/2"x 0.1351;or <br /> 2-16d common(31/2"x 0.162'0;or End nail <br /> 3-10d box(3"x 0.128');or <br /> 3-3"x 0.131"nails <br /> 3-1Od box(3"x 0.128");or <br /> 17 Top plates,laps at corners and intersections 2-16d common(31/2"x 0.162');or Face nail <br /> 3-3"x 0.131"nails <br /> 3-8d box(2'/2"x 0.113');or <br /> 18 1"brace to each stud and plate 2-8d common(2'/2"x 0.131'�;or Face nail <br /> 2-10d box(3 x 0.128 D,or <br /> 2 staples 13/4" <br /> 3-8d box(2'/2"x 0.113');or <br /> 19 1"x 6"sheathing to each bearing 2-8d common(21/2"x 0.131");or Face nail <br /> 2-10d box(3"x 0.128),or <br /> 2 staples,I"crown,16 ga.,13/4"long <br /> 3-8d box(2'/2"x 0.113');or <br /> 3-8d common(21/2"x 0.13 V ;or <br /> 3-10dbox(311x 0.128'D;or <br /> 3 staples,1"crown,16 ga.,13/4"long <br /> 20 1"x 8"and wider sheathing to each bearing Wider than 1"x 8" Face nail <br /> 4-8d box(2'/2"x 0.113');or <br /> 3-8d common(2'/2"x 0.131'�;or <br /> 3-l0d box(3"x 0.128');or <br /> 4 staples,I"crown,16 ga.,13/4"long <br /> Floor <br /> 4-8d box(21/2"x 0.113');or <br /> 21 Joist to sill,top plate or girder 3-8d common(2'/2"x 0,131');or Toe nail <br /> 3-10d box(3 x 0.128�;or <br /> 3-311x 0.131"nails <br /> 8d box(21/2"x 0.113'� 4"o.c.toe nail <br /> 22 Rim joist,band joist or blocking to sill or top 8d common(21/2"x 0.13I'D;or <br /> plate(roof applications also) 10d box(3"x 0.128%or 6"o.c.toenail <br /> 3"x 0,131"nails <br /> 3-8d box(2'/2"x 0.113');or <br /> 23 1"x 6"subfloor or less to each joist 2-8d common(21/2"x 0.13l');or Face nail <br /> 3-10d box(3 x 0.128%or <br /> 2 staples,1"crown,16 ga.,I%"long <br /> (continued) <br /> 2018 INTERNATIONAL RESIDENTIAL CODE® 175 <br />