SCOPE OF WORK Permit#: K2407-010 <br /> 1. MODIFY EXISTING SPRINKLER SYSTEM TO ACCOMMODATE NEW TENANT IMPROVEMENT Site Address: 7007 Seaway BLVD <br /> WORK INCLUDING NEW WALLS AND CEILINGS. Applicant: Derek Strickland <br /> 2. EXISTING SYSTEM IS TO REMAIN OUTSIDE AREAS OF WORK. Application Date:0713012024 <br /> 3. EXISTING OVERHEAD PIPING, SPRINKLERS,AND HANGERS ABOVE NEW CEILINGS TO Description: Adding 254 new sprinkler heads for T.I. <br /> REMAIN. Review Date: 08/01/2024 <br /> 4. ALL NEW THREADED PIPING IS TO BE SCHEDULE 40 BLACK PIPE. <br /> EVERETT <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown HANGER LEGEND <br /> 08/01/2024 12:26:20 A "U" HOOK <br /> PM <br /> B COACH SCREW ROD <br /> D BM. CLAMP W "STRAP <br /> APPROVED E EYELET <br /> PUBLIC WORKS DEPARTMENT F FLUSH SHELL <br /> BY:THerman G CEILING FLANGE <br /> DATE:08/01/2024 H SIDE BEAM BRACKET <br /> CITY OF EVERETT REVIEWED FOR PERMIT K SHORT CLIP <br /> M ALL THREAD ROD <br /> IN TOGGLE NUT <br /> P POWDER DRIVEN STUD <br /> R EXPANSION BOLT <br /> TPO ROOFING SYSTEM T SAMMY XPRESS <br /> E OVER RIGID INSULATION B A D <br /> OVER 11/2" 20 GA METAL DECKING 12" w <br /> OVER METAL STRUCTURE 3/8" Y <br /> z <br /> APPROVAL REQUIRED <br /> CITY OF EVERETT <br /> METAL BAR JOISTS AT PEAK <br /> 30'-2" PER STRUCTURAL AT PE 30'-2" <br /> O ":iFMP RnilxG(r) J112 <br /> 212'286'S50' ti QM Soo' /1' <br /> —METAL COLUMNS FITTING LEGEND <br /> CONCRETE TILT WALL PANEL PER STRUCTURAL P PIPE LET <br /> SN GROOVVEE D SHAPED NIPPLE <br /> CONCRETE SLAB ON GRADE TSN THREADED SHAPED NIPPLE <br /> �` <br /> ADN ADJUSTABLE DROP NIPPLE <br /> FIG FLANGE <br /> RC REDUCING COUPLING <br /> 0 STRUCTURE TO CENTER <br /> / UNE OF PIPE IN INCHES <br /> r---o_____a/ 2-WAY EARTHQUAKE atACE <br /> I-WAY EARTHQUAKE BRACE <br /> A BUILDING SECTION a �3! SPRINKLER LEGEND <br /> 1 i'o 1 SPRINKLER <br /> ORIFICE SIZES EI '•' w ri <br /> FP 1 SCALE: 1/8"=1'-L" �r�e¢ d �= AND TYPE EI <br /> W �� <br /> 1 LVG 1 1 1 IG B IS I SPRAY O • I^ <br /> 1 E52 <br /> I ❑ <br /> YI <br /> Q ; C 1 3 I) A 3/I <br /> 3NI� )112J3d02Jd N 1 tz SPRAY a❑ 1^ <br /> 1 <br /> 1 Li a i e 1s z SIDEWAIL 4 <br /> INSTALL: <br /> .'.' INSTALL: <br /> 1-8" 45 BEND INSTALL: INSTALL: 1• 2 oar TYPE <br /> i1,-8"x6"TEE MJxMJ ® 1^ <br /> THRUST BLOCKING 1-S!-'a,xt6"TEE MJxMJxFL A 1-8"x6"TEE MJxMJxFL 2-8" GATE VALVES MJxMJ 60 LF 8" P 52 FLOW TEST <br /> T—rNtE HYDRANT ASSEMBLY A 1-FIRE HYDRANT ASSEMBLY SPRINKLER HEAD LEGEND <br /> THRUST BLOCKING THRUST BLOCKING 1-8' GATE VALVE BLOCKFLxMJING <br /> STALL: STATIC <br /> " <br /> FP-1 THRUST BLOCKING STATIC 61 PSI HEAD 11`A HERB fSC1TW <br /> -8" 45 BEND m uwuF. MODEL SIN nPE waxcx vzE FACTOR nxlsx nxnx Toe on <br /> H FH HRUST BLOCKING <br /> RESIDUAL 20 PSI <br /> 14 LF B" DIP CL 52�_ 84 LF 8"DIP CL 52 261 LF 8" DIP CL 52 <br /> 478 LF 8" DIP CL 52 <br /> F <br /> UG3 43 L " DIP CL 5N2 FLOW 2,052 GPM <br /> 3B LF B DIP CL 52� uc4 INS8A 2`BEND ELEV 517.81' <br /> IRIS A L: WALL DST RUS KING DATE 1 1 16/2022 <br /> 30 LF 8" DIP CL 52 FIRE SUPPLY LINE------ 1 INDIC OR LOCATION NODE 11546 <br /> 1-8" GATE VALVE MJEf�D <br /> THRUST BLOCKING DOUBLE DETECTOR CHECK VALVE ASSEMBL <br /> DATA BY EVERETT PUBLIC WORKS <br /> LOCATED INSIDE BUILDING <br /> VALVOTAL <br /> 90 LF 6" DIP LINE - CKI <br /> CKING �O� DUALIn CONTROL BY BATE <br /> 75 CL 52 �9 APPROVED FOR FABRICATION BY DATE <br /> G, GENERAL NOTES <br /> ALL NATfaAL AND IOURMLNT TO BE HEW AND UL USTED OR FM APPROVED. <br /> PROPOSED BUILDING N 2. PIPE ENIENSIOISTHUSLY ARE CENTER TO CENDR END.RISERS A DIMENSIONS <br /> 186,024 S F MJxMJ l SROWN KE GR(x-%)HALL ARE END ro END. <br /> 3. FARMQUAM MACIN.SHALL H PROVIDED IN ACCO�ANGf M1H <br /> P. 1- ANT A LY �,� xFP PAVPx1Er NO.a,zo1G Ean°x. <br /> FF=522.9T T KING 000000�o�� DESIGN CRITERIA: PIPFIRAPIK AND 13.2FON. �GRDNGEWRN <br /> NF A MORSIR NO.METHOD zOF HANGING EMNGX. <br /> ;11IS,2016 EDIIION <br /> 0000000000000000000000 MoouooUM ACTUAL STORAGE HEIGHTS VARY — 36" MUST BE """` o, BE IN �"°"""W�"FP"`"MPH ��IN GDRD'I <br /> r <br /> MAINTAINED BETWEEN TOP OF STORAGE AND SPRINKLER DEFLECTORS „",""" "EP"`o`FOIN"=ASE��"DED o000 0000 7.OWNER TO PROWDE ADEOUATE HEAT IN AREAS PROTECTED BY A WET PIPE GFRINKIER <br /> SYSTEM TO PREVENT WATER IN PIPES ROM FREEZING. <br /> 1. WAREHOUSE & MAIL ORDER: MAX STORAGE HEIGHT 12'-0" s.A�OTMIfGGGOr aECTRIU.GDNCES(IF REGUIRED)TO BE PROVIDED <br /> VVVV �V DESIGN STANDARD IS NFPA 13 USING RELIABLE'S JL-112 EXTENDED 9. PAINTING OF PIPE&EOUIPYENT(IF REQUIRED)TO BE PROVIpEO <br /> COVERAGE PENDENT SPRINKLER HEAD WITH A MINIMUM FLOW PRESSURE B OG. <br /> 10.FURRING Of PIPE k EQUIPMENT(IF REQUIRED)i0 BE PROVIDED <br /> OF 51 PSI WITH A MAXIMUM 15' HIGH ROOF FOR ORDINARY HAZARD BY OTHER` <br /> ` GROUP 2. THIS DESIGN ALLOWS FOR STORAGE OF THE FOLLOWING DESIGN CRITERIA <br /> 1 COMMODITIES: <br /> NSTALL: <br /> THRUSTS BBEND <br /> LOCKING !N1 TA L: PALLETIZED, BIN BOX, SHELF AND SOLID PILED STORAGE: <br /> 1a" 2zs EN INSTALL: PER TABLE 13.2.1 (NO OPEN TOP CONTAINERS) SEE NOTES THIS SHEET <br /> THRUST LOG <br /> G <br /> 1-8" INSTALL:x8" TAPPING TEE 22.5 BEND <br /> '''''' ''' THRUST BLOCK — ucs A. CLASS —IV ENCAPSULATED COMMODITIES <br /> ,',',',' INSTALL: 41 LF P CL 52 65 LF 8" DIP CL 52 ❑ 5ti 1-T TAPPING V E <br /> 45 BEND ° THRUST cKl MAXIMUM STORAGE HEIGHT = 12'-0" <br /> a'1-8"a"TE*VALVE MJxMJ F INSTALL:z B.CARTONLD NONEXPANDED PLASTICS <br /> ' 'T,NRLIST BLOCKING PIPE NOTES <br /> 1-8" 22.5 BEND F MAXIMUM STORAGE HEIGHT = 5'-0" <br /> ' THRUST BLOCKING <br /> 4z LF 6" DIP CL sz z7/F C. EXPOSED NONEXPANDED PLASTICS <br /> 58 LF CL 52 H a'°p 5 F 8" D CL 52 MAXIMUM STORAGE HEIGHT = 5'-0" <br /> ® -8"x6"TEE MJx MJxF <br /> 1-8"x6 xMJ 7 F 1-FIRE HYDRANT E LY <br /> 1-FIRE HY SSEMBLY. THRUST BLOCKI RACK STORAGE: PER TABLE 13.2.1 REVISIONS <br /> THRusT BLOC ING,','.','. INSTALL: H h`v INSTALL: SINGLE—ROW, DOUBLE—ROW, & MULTIPLE—ROW RACKING NO GATE BY BESCRIPTION <br /> 1E HYDRANT <br /> TEE ASSEMBLY v 1-8" 22.5 BEND FP (WITHOUT SOLID SHELVING) <br /> 1-FIRE HYDRANT ASSEMBLY -I Q THRUST BLOCKING �PZ <br /> THRUST BLOCKING S<F o (NO OPEN TOP CONTAINERS) <br /> • 56 LF 8" DIP CL 52 g, � �� <br /> °'pc �g 18 LF 8" D 2 <br /> INSTALL: A. CLASS I—IV ENCAPSULATED OR NONENCAPSULATED COMMODITIES <br /> 1-8%6"TEE MJxMJxFL sz� MAXIMUM STORAGE HEIGHT = 10'-0" <br /> -B GATE VALVE BFLxMJ <br /> LOCKING <br /> B.CARTONED NONEXPANDED PLASTICS <br /> THRUST BLOCKING O — <br /> ucz MAXIMUM STORAGE HEIGHT — 5'-0" J <br /> INSTALL: 45 LF 8" DIP CL 52 C. EXPOSED NONEXPANDED PLASTICS < <br /> 1-8° TEE MJxMJxFL MAXIMUM STORAGE HEIGHT 5'-0" FOUSHEE & ASSOCIATES COMPANY, INC. <br /> ' 1-12" GATE VALVE <br /> BELL - , WA AVE 11 SE <br /> 1-12x8" REDUCER MJxFL UGl � BELLEVUE, WA 98005 <br /> 2-8" GATE VALVES FLxMJ INSTALL: 2. OFFICES, BATHROOMS & BREAK ROOMS: MATTHEW CHILES: 425-746-1000 <br /> THRUST BLOCKING INSTALL: 1-16"x8"TAPPING TEE <br /> 2-8" 22.5 BEND / 1-8"TAP PROJECT MINE: <br /> VALVE LIGHT HAZARD C <br /> THRUST BLOCKING THRUST BLOCKING G <br /> SRC m MCKESSON TI <br /> 55 LF 8" DIP C 52 <br /> 7007 SEAWAY BLVD <br /> EVERETT, WA 98203 <br /> ' �/P PATRIFP099CF <br /> , ' +PATRIOT WWW.PATRIOrFIRE.COM <br /> pielrod®pOlriotf ire.com <br /> SITE PLAN FIRE PROTECTION,INC. <br /> TACO A, AVENUE EAST TEL: (253) 922-6150 <br /> _ SCALE:1"=50'-O" TACO MA, EK 98424 FAX:(253) 922-6150 <br /> DESIGNER EREK STRICKLAN SHEET <br /> DATE 7/29/24 F P 1 <br /> JOB NO. 11-2410 OF 5 <br />