Laserfiche WebLink
SLIDING GLASS DOOR <br /> SELF ADHESIVE PER AN - y <br /> MEMBRANE PAN SLIDING GLASS DOOR EXTEND MIN,6'UP JAMB - <br /> FLASHING \ NAIL FLANGE <br /> NAIL ON FLEXIBLE GALJ` < FLASHING NERVA5TRAL TO EXTEND <br /> 2'PAST THE INTERIOR \ HEADER/ \ HEADER <br /> / <br /> FLASHING / 2 M':N FROM IG'r OF OF THE DOOR <br /> FLOOR JOIST / LEDC,ER TO LAG SCREW \ / <br /> STD <br /> PER PLAN—� PER CEDAR DECKING _ ROUGH ROUGH <br /> PER PLAN BA RI - OPENING OPENING <br /> `\�N 2x P-JOIST PER PLAN BARRIER - - J AMB\ <br /> _IAMB <br /> JOIN ., r Ir- <br /> \ JAMB <br /> I H 11'D ANGER PER FLAN PIECE / SILL \ / SILL \ <br /> INS L r PL4,kh 1 <br /> RIM JOIST-� * I IN MJ�ERATE _ PENETRATION - <br /> l PT LEDGER PER PLAN CONTACT---- /ST 6" <br /> BUILDING-PAPER -. - P/ECE <br /> INSTALLED BEHIND SHEATHING PER PER PLAN 12• SILL <br /> SIDING DER FLASHING <br /> LEDGER AND PAN ---SIDING PER LEDGER NSTALLEDLAN BEF TIE 7;DPJu PLAN -- --r BUILDING PAPER TO EXTEND <br /> FLASHING.LAP _ J -..-_ <br /> MIN.12'HE BEYOND ALL EDGES S 1 STEP 2 <br /> OVER HOUSE WRAP EXTEND 12'BEYOND -ATTACH SILL STRIP OF 9'WIDE MOISTOP(OR EQ.)FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9"WIDE MOISTOP(OR EQ.), <br /> w/BUILDING PAPER BEHIND IT w!a' - OF THE PENETRATION <br /> EXPOSED ON ALL 4 SIDES - OPENING WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH IN51DE EDGE EVEN WITH THE JAMB <br /> _ _ -EXTEND THIS STRIP AT LEAST 12'BEYOND THE EDGE OF THE ROUGH OF THE ROUGH OPENING. <br /> DECK LEDGER DETAIL SI ul�u 1 J FLASHING OPENING. START JAMB STRIPS 2"BELOW SILL STRIP AND EXTEND 6" <br /> W�2 EXTERIOR DOOR FLASHING PENETRATION PROTECTION ATTACH FLASHING MATERIAL WITH CORROSION-RESISTANT STAPLES. ABOVE LOWER EDGE OF HEADER. �y� <br /> W16 1W15/ Wl <br /> N.T.S. SCALE N.T.o. \J SCALE:N.T.S. 4 SCALE:N.T.S. CID <br /> osrtrR iRn way cN o <br /> FFIXl���i w�w.as CONY.BEAD OF <br /> HEAD -- - SEALANT <br /> EQ. EQ. LASHING UNDER NAIL FIN <br /> OPERABLEI FlY.ED I PER P 2' 2°5G01- <br /> PARR I- - -- PANEL-JJ CUT AWAY <br /> LINE of _ 111J WINDOW EXCESS <br /> iel .1 <br /> NERVESTRAL __ ___ _. _____ �ARrw000 CEDAR TRIn, FRAME OR BLDG.PAPERFRAME OR <br /> 1 .AL sDEs ow1.K/SEAL SIMILAR @ OPENING SIMILARH ' I- - FA. OPENINGOPENING <br /> BI70MOF 3'•5'LANDING TYP. #NOTE: SEAL ALL.. 1 PaR AGAINST BUILDING PRONTO NERva5TRAL EXPOSED FASTENERS BUILDING PAPER <br /> BEND FRONT I PATIO SHEATHING PER PLAN PAPER TYP, <br /> ELECTRICAL V-6'LANDING TYP. TYP. <br /> METER MAIN tm—� <br /> @BACK PATIO's INSULATION -. BLDG PAPER NAIL FLANGE UNDER SILL STRIP <br /> APPROVED(LASHING <br /> FRONT-...__ PRONTO BENDPER PLAN <br /> INSTALLED ON axc HEAWT,00D cEnAR TRIM STEP 3 STEP 44 <br /> CORNER Ocrtt --PER PLAN.PouR APPLY(0.19 x 10"ROLL) O <br /> OF HOUSE €%S.OF NOOSE T +xO AGAINST NERVESTRu z:A HEARTrt•+oo0 CEDAR SIDING PER PLAN -I/2"GAP •HAING FLANGE I ALL USIpES OF T EAWINDOW THE BACK OF THE FRAME •fRRME OPENING)OVER LY THE NEXT �THE JAMB E OF FLASHBUILDING NGEMATERIAL.G TO THE <br /> AT GARAGE BIBBHOSE 30tt FELI -PE<. --- ----- Twn w/FLASHING P BTWN ROOF AND SIDING PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE .APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE <br /> BIBB NER4ESTRAL HGUSE INTERSECTION, co <br /> STARTER. TkIP - LANDINGpEP P au _ _ WHERE occuRs INSTALLED JAMB AND SILL t JAMB MOISTOP(OR EQ.)FLASHING MATERIAL. BOARD FASHION UP THE WALL,LAPPING COURSES A MINIMUM OF <br /> INSTALL (MIN .5',irF r ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS 1/2 PAPER WIDTH. <br /> GROUNDING GUTTER-'_k _ STEPS's0 BY LINE a NERVESTRAL •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER <br /> 3 MUD slu -7EcnJorFlors 1 30n FELT TO EXTEND UP <br /> ROD TO FROM .5 - _ - THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND <br /> SLAB qI�pDE WALL 12'MIN. <br /> PRONTO BENG Caec.wAu - ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING. <br /> FORTffLA56 0/FLASHING r= •ADD FORTIFLA514 STICK FLASHING @ BOTH SIDES OF WINDOW <br /> FLASHING <br /> Lu <br /> AND MOISTOP.TURN 9 tN.:TOr PLAN - ROOF TRUSS _ _; ,;! Ac - •APPLY SLOPED 28 GA 2'BACK,PREFIN15HED METAL FLASHING TO OPENING. <br /> FORTIFLA541 r ONTO PANEL, ROOF SHEATHING PER PLAN .APPLY 0 FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST <br /> FASCIA PE ` J EXT. LANDING DETAIL @ ROOF TRUSS <br /> ALL SIDES f CORNER:. JAMB FLASHING 2". <br /> 2,2TRIM1 PERIMETER— TY fL SIl�N� i, @ EAVE �n SLIDING GLASS DOOR/ TYP ROOF TO WALL FLASHING �p� STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS Q <br /> OPENING FOR ELEC.- -- u B G W13 COL_,Ni S WI2 SCALE:N.T.S. �I/ SCALE:N.T.5. '`I� <br /> METER BOX,PREPLACE A,_k Bt,.IJJL� SCALE:N.T.S. <br /> DIRECT VENT,RANGE VENT, METEk MAIN y _ <br /> DRYER VENT, ETC. SEALANT WINDOW FRAME <br /> +SEE DETAIL AID FOR iOiSTGP INSTALL IN5TROCTIC;iS 3/8'BEAD CAULK INSULATION 7/16"PLYWD.SHEATHING <br /> SILL ASSEMBLY <br /> M Ey <br /> ELECTRIC IETER t HOSE UIC PER SPEC-- SEALANT (WHERE OCCURS) fORTIFLASH 0/FLASHING <br /> �vI TRIM PER ELEVATION GYP.BD. HD.FRAME WALL SIDING PER PLAN <br /> 1rLOCATON (NO GAS I IETER) (WHERE APPLICABLE) INSULATION PER PLAN BUILDING PAPER <br /> W5/ SALE:N.T.S TRIMMER (WHERE OCCURS) R-10 INSULATION M015TOP(SEE DETAIL WINO <br /> GYP.BD. MOISTOP(SEE DETAIL KING STUD BEHIND HDR,TYP @ FOR INSTALL) <br /> WI0 FOR INSTALL) WD.FRAME WALL ALL HDR's <br /> SEALANT PER PLAN MIN.114"GAP BTWN SIDING <br /> fill <br /> ._. 'MIN.18' EXT WALL PER I FORTIFLASH ON ALL GYP.BD.- AND FLASHING COPYRIGHT NOTICE:TH15 <br /> PLAN ` SIDES OF WINDOW MOISTOP(SEE - PLAN 6 OWNED BY PACIFIC <br /> - - - DETAIL WIO 7/16'PLYWD.SHEATHING HEADER PER PLAN FLASHING <br /> HI EACUREN�N \ R�EI 15.PROW10EBITED BY <br /> - SIDING PER PLAN FOR INSTALL) 114' NITHM PAYMENT OF <br /> INSULATION WINDOW FRAME ---TRIM PER ELEVATIIXJ _ICtNSE FEE r0 PACIFIC <br /> APER TYP. (WHERE OCCURS) BLDG.PAPER BLDG.PAPER SEE ELEV.FOR RIDGE HOMES. <br /> 10'-6°TO HOSE B10 SEALANT (WHERE APPLICABLE) <br /> C 'ER PLAN SIDING PER PLAN WINDOW HT / <br /> I6°7/ PLYWD.SHEATHING <br /> 8'-6`70 C.L. 1 TRIM PER ELEVATION SEALANT PLAN SUMMARY <br /> 111 9ED TRIM FORTIFLASH ON ALL <br /> OF PRONTO BEND I (WHERE APPLICABLE) SIDES OF WINDOW SEALANT �-_WINDOW FRAME uvaassR�rnn. <br /> °° W9 �I Ih G l::.c )RNER WS WINDOW SILL @HOOD FRA�1E WALL WINDOW JAM6 DETAIL ( 1 WINDOW HEAD DETAIL . <br /> EWE TO EDGE TO LI'T I,I/ 814 <br /> EWE EWE _ ELECTd;.;-1 SCHLIE'J SCALE:N.T.5. VV! VVIO <br /> SCALE:N.T.S. SCALE:N.TS. <br /> i1ETER ftAlrV <br /> FRONT-1 ® f PRONTO BEND 'IIgS <br /> CORNER I _ INSTALLED ON <br /> EYT z'r @ <br /> O POINT LOADS ABOVE VENTS F HOUSE - OF dCUSE LAP SIDING,U.NO.(HOLD 1-1/2' 57UDS I6°a NO P0575/ - -2009 <br /> AT GARAGE - ''� H05E LAG SCREW OFF ADJOINING ROOF) / ) - wev�AaAm.... <br /> GAS BIB3 _Y ATTACHED METAL FLASHING f L SIDING PER PLAN---�_ � 405 <br /> METER �NSA,L'1 - STUDS.LAG (MAY BE STEPPED) it BOTTOM SILL PLATE <br /> i <br /> ROUND'+1 - D PENETRATE BUILDING PAPER ON J % GAS <br /> I_ MIN.,TYP.@ ..- 3/4 TK,SUBFLOOR - <br /> - ROD 1'��F SHEATHING(SIDING CUT I,I unnen.0 w.wc wvmuTwA <br /> - _-- PRGNTG EE`ID JG 2/3 HT OF AWAY FOR CLARITY) a ICI FLA5HING JWq <br /> FORTIFLASH o!FLASHING TACH w/1 +'*- 7-1/2 CEDAR RIM <br /> AND M015TOP TURN ��9 MGLTCr A.STRAP MIN METAL RAIN INVERTER(THE o I VENTS w/GALV SCREEN- F <br /> FORTIFLASH I'ONTO PANEL, PURPOSE 15 TO SHED THE I' PROVIDE LOUVERED VENTS BTL ENGINEERING <br /> ALL SIDES f CORNERS. HT HWT WATER OFF THE ROOF AND @FROM'ELEVATIONS <br /> -FLA.=r.li4G KEEP IT AWAY FROM THE ROOF SHINGLES RSEE REVISION LOG <br /> 22 TRIM @ PERIMETER TYP) VERTICAL WALL BENEATH), PER SPEC. RIM PER PLAN <br /> OPENING FOR ELEC_ -60 I'iIIJ.BIDE J7 OF NWT �-P.T.MUD SILL ° c <br /> METER BOX,FIREPLACE PAPER a LC FASCIA PER PLAN 30#ROOF FELT <br /> w/ '�%'� CONCRETE FWNDATION 5C•ALE: Y'=I'-0' <br /> mans <br /> VENT,ETC. 7/10 055 ROOF $ADO NOT INSTALL VENT(5)CLOSER THAN 3'TO GAS METER,, WATER <br /> DRYER VEN <br /> DIRECT VENT, R VENT,. METER s,I;J GUTTER / � \ SHEATHING -BUILDING PAPER 544OULD BE INSTALLED OVER FLASHING" INTRUSION <br /> SEE DETAIL WIO FOR MOISTOP INSTALL INSTRUCTIONS - [NOTE;PER WSEC R40'[.2.7:WHEN FOUNDATION VENTS ARE NOT PLACED SO THAT THE TOP DETAILS <br /> C NOTE: SEAL ALL THE VENT I5 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY <br /> ELECTRIC t GAS ["IETER HOSE TACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO <br /> 1 r USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS VERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. <br /> �815 CLEARANCES t LOCATIONS _ WATER HEATER (HWT) STRAPS T DETAIL @ ROOF/WALL INTERSECTION FOUNDATION VENT <br /> SCALE:N.T.S. yV' <br /> - SCALE:N.T.S. <br />