My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9506 7TH AVE SE 2024 Plans 2025-08-20
>
Address Records
>
7TH AVE SE
>
9506
>
Plans
>
9506 7TH AVE SE 2024 Plans 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 10:22:36 AM
Creation date
8/20/2025 10:20:35 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
9506
Permit
B2402-068
Year
2024
Notes
NEW SINGLE FAMILY HOME-RB2306-001 THELON-CHELSEA HEIGHTS 01
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLOOR PLAN NOTES <br /> CCU,a BHBER, <br /> Sloe <br /> I. CONTRACTOR SHALL VERIFY ALL NOTES,MATERIALS t CONDITIONS PRIOR TO ---- <br /> CONSTRUCTION. EQ. 69. .-... <br /> SGD PER PUN DOOR d JAMB- V <br /> WINDOWS B DOORS: OPPANELERABLE PANEL CAULK BACK OF <br /> 2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULATED w/R-IO INSULATION. __ THRESHOLD TO WRAP NERVASTRAL <br /> 3. WINDOWS t DOORS ARE SHOWN t NOTED AS NOMINAL SIZES. 'ESTRAL - -- --""---I 2a HEARTWOOD CEDAR TRIM, NERVESTRAL UP JAMB 6' <br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRESS WINDOW SILL HEIGHT R.O.@ ND CEO.ALL SIDES,CAUWSEAL t ALL SEAMS (2)R6'BEADS OF <br /> MAX.42'A.F.F. EQ. - I EQ. CAULK UNDER <br /> 5. ALL WOOD IN CONTACT WITH CONC.TO BE PRESSURE TREATED. IG Of i "'llll V&LANDING TrP. _ - NERVE5TRAL,(1) <br /> n. I POUR AGAINST P SIDES OF JAMB <br /> 6. EXTERIOR WALLS TO BE 2x6 STUDS @ 16'O.C.,U.NO. NERVASTRAL WRAP EWE t <br /> 7. GARAGE DOOR HEADERS @ 84'A.F.F. PRCNr PORCH PATIO THRESHOLD w/ I,I 30'-0. <br /> 8. EXTERIOR SWING DOOR HEADERS @ 83 1/2'A.F.F. 3'-0 LANDING TYP. m P.rae sxxxn owns ADD'L NERVASTRAL '.,I NERVASTRAL OR EQ - <br /> 9. INTERIOR SWING DOOR HEADERS @ 83'A.F.F. @BACK PATIO'S Q. BE Px.PEo IN TxE mRe 1. IT-0' 151-0' <br /> 10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS OR BE 3"MIN.ON HINGE SIDE, s4.o wrEBN�Evix� THRESHOLD DETAIL <br /> 11. GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD IV THICK 20-MINUTE FIRE-RATED DOOR �r1,� 2.6 HEARTWOOD CEDAR TRIM Dq SCALE: 1-1/2' 1'-0' 17'-0' 4'-0' 5'-0. 4'-0' ' <br /> w/A SELF CLOSING HARDWARE DEVICE. �I+; AGAINST PER PLAN.wUR <br /> 12. PER R311.3.1:THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL E/I LRiOR DOORS IRES40LD AGAINST PER PLAN L 2.6 HEARTWOOD CEDAR S <br /> 5'-I�1 6'-0" l-1 <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4'BELON THE TOP OF THE --- ------------- TRIM W FLASHING a 24'x36"NEAT <br /> NERVESTRAL I HOUSE INTERSECTION, PUMP BASE. <br /> THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER 7FIE LANDING 012 FLOOR I wJERE � <br /> -LANDING PER PLAN _ _ WHEN GARAGE �- <br /> 13. ALL BI-FOLD t BI-PASS DOORS TO BE CENTERED,U.N.O. WI2� OPT.SELECTED, <br /> (MIN.STEPS <br /> TYP.) I ///J II��`]� <br /> - O STEPS TB D BY ' LINE of NERVESTRAL D40 4 u VERIFY LOCATION <br /> :'a"L <br /> .SITE CONDITIONS 3 <br /> FRAM I 3'x4'CONC. w/SITE SUPER <br /> i4. VERIFY FIREPLACE STYLE t LOCATION w/SUPERVISOR PRIOR TO CONST. L BLAB ON GRADE _ -^I LANDING �'(1 <br /> 15. FRAMERS TO INSTALL ALL WINDOWS t INTERIOR COLUMNS _ <br /> 5040 XO <br /> SEE me Fca rmxr rox <br /> . TOWEL RING BLKG @ A.F.F 17 O I Q I 1 <br /> 17. TOWEL BAR BLK @'G 48'A.F F t BLOCK BOTH BAYS. /Y �- SOFFIT TO BTM OUTDOOR - O <br /> 18. TOILET PAPER HOLDER BLKG @ 22'A.F.F.AND 42'FROM BACK NAB iIE EXT. LANDING DETAIL l <br /> K r05515LE a 'r -.3`.°" 2568 U <br /> 19. THERMOSTAT BLKG @ 60'A.F.F ( OF BM'TYP 1710X510 <br /> 20. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRYS SHALL BE INSIALLED-.i 7''-6'A.FF. SLIDING GLASS DOOR TYP `.J <br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE LI <br /> GARAGE DOOR TRIM W12 SCALE:N.T.S. 6040 XOX NOOK <br /> 22. ADD CONT.BLOCKING FOR STAIR HANDRAIL BRACKETS IOIx1 b 1 1 <br /> 23. STAIRS w/WINDER STEPS WILL ALWAYS HAVE A CONTINUOUS HANDRAIL M57ALLED ON - L.L <br /> THE dSO OF THE STAIR's RUN EQ. EQ. CPT W <br /> 24. LADDER-BLOCK AT EXTERIOR WALLS AS NECESSARY FOR INSULA"f IOIv INS U;LL CPT <br /> T .n 3'-9' 28° 4-0" 2'-5' <br /> VENTILATION' ROUT O VR PER PUN INSTALL(2) <br /> 25 WHOLEACCOR HOUSE <br /> E VENTILATION <br /> ENTILATfl TIIONI SHALL BE PROVIDED BY A CENTRAL EXHAU5f FAN IN - -`I._ 2CM OVERHANGS TO BE 12 t BLKNG FOR <br /> N4 �DIa KID 3CM OVERHANGS TO BE 12" �+ = RANGE uceD <br /> 26. WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY. FRalT a SLAB -- BOTH SIDES <br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M1505.4.3(1).EXAMPLE:70 CI-M FOR 2600 - q�_p" 1325 _ D/W DW AIR I LAOF . <br /> SF HOME w/4 BEDROOMS,AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE ELEVATION+�T- <br /> DOOR THREs1aL0 s ELECTRIC GREAT ROOM . E GAP,S DK IDE <br /> MI505.4 3(2)TO ACCOUNT FOR NOT-BALANCED,NOT-DISTRIBUTED VENTILATItk!SYSTEM. 21B P ;� FIREPLACE I514XI71 '? B o I - <br /> 28. WHOLE HOUSE FAN SHALL BE 1.0 SONE5 OR LESS,AND SHALL HAVE AN EFFICACY OF 2.6 RAISE (2y1.4's TO BE <br /> CFM/WATT PER WSEC R403.6.1. RIPPERET70VED PRIOR ;, <br /> 21 W W TO FRONT c� <br /> DOOR <br /> 29. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE wINGOriS PER STATE N'wpo BER�BEING 5 ® CENTER <br /> CODE INTERPRETATION 17-15. ER <br /> _ ®y STUD BAY <br /> 30, PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN FHE ROOT 1 WITH THE ER PLAN _ 1�WHOLE HOUSE FAN. G PAPER -. o _ F ON RANGE <br /> DOOR <br /> 3I. PER IRC M1502.4.5.:WHERE THE DRYER VENT EXHAUST DUCT 15 CONCEALED WITHIN THE �� _ CPT CNEN SEE CABUT <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE PLA FRONT +T.O.RAISED RUN FAN _ I I FORLOCmIDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG oNALL BE LOCATED w FRONT xRa PORCH DUCT TO 3'_I 6,�,. T,_ m ql_1 10 bxl2 37,rSLAB.SLOPE STEM WALL TO �2' 2 SVi" - 1i' 1WITHIN 6FT OF THE EXHAUST WCT CONNECTION. N - N PER uN. 5 ,. T.O.FRONT POF TOILET or+ FT.MAN. STEM WALL•P SINK HALL, 2x6 WALL MINI-SPLIT 40 BF � <br /> LIFE SAFETY: DOWN ruRu REFER <br /> 26. A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR 7"EMPERATURES AND / � _ CRAWL P �3_4LR_ _______� � <br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE. D;ZFRONT PORCH EXT. DETAIL _� SPACE t _ -1 VJ/5(3) OPEN'G <br /> 27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE SCALE:I/2'=I'-0' ELECTRIC Ij VENT TO - SD/CO O <br /> ALARM THAT 15 INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY,ROOM OR m OUTSIDE - <br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION FIREPLACE OPT. 2 ALLED IN <br /> 660 F i/4Yx`d NWT TO BE p Y 1 <br /> 10. SMOKE DETECTOR5 TO BE IIOV, INTERCONNECTED,w/BATTERY BACKUP t CLNITRALL'E - b, x 7p D N5 'm W LR3,� THE 3rd CAR t--t--E <br /> LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE SCALE: 1/4' V-O' I 1 � 2866 GARAGE OR Cfl <br /> INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 3 6 GARAGE \ <br /> I. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROM THE 4'BOLLARD D' <br /> 3 BUMP-OUT WHEN <br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER(R314] - �TR �_ _ LINE OF THAT OPT.IS `. <br /> 12. IONIZATION SMOKE ALARMS: FUR ABV SELECTED. <br /> + SHALL NOT BE INSTALLED LE55 THAN 20 FT HORIZONTALLY FROI A PERINANENILY <br /> INSTALLED COOKING APPLIANCE. <br /> B IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH SHALL ItiF BE INSTALLED NI •x T LPTN <br /> LESS THAN 10 <br /> FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. -i t uu1 �i �� 2468 GARAGE <br /> 24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LE55 THAN 6 FT <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE IR314] IIT - Iq'IXIq'7 <br /> I8°x24'CRAWL coPrRIGUT NOTICE:THIS <br /> 25.GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2'G W.B.d 5/8" ;Ra Im GARAGE NOTE:WRAP ALL WARM ;' PLAN 15"ED BY PACIFIC <br /> TYPE'X'ON THE CEILING.POLY SEAL RIM,ENTIRE GARAGE TO I-IEET JURISDICTION r, m SPACE ACCESS WALLS AND SUPPORTING MEMBERS K$ r,IDGE HOMES.USE OF THIS <br /> DRAFT STOP REQUIREMENTS b WITH I/2°G.W.B.d 5/8"TYPE'X'ON alpW IS EWIIBITED 8Y LAW <br /> 26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECTED WIT H T'GWB A.T THE BT FOYER THE CEILING OF <br /> WITHOUT <br /> FEE TO PACIFIC <br /> WALLS,UNDER-STAIR SURFACES AND SOFFITS. Tnrr " RIDGE HOMES. <br /> 27. PROVIDE FIREBLCCKING PER PLAN AND @ ALL PLUMBING PENETRAliONS. <br /> 36'KNEE <br /> WALL BELOW 35%HALF AIO PLAN SUMMARY <br /> xT WALL uelLevaaexeen <br /> sr E FOR <br /> sr rr 'U UTILITY <br /> 3' <br /> LAYOUT, <br /> SEE W5/AIO 814 <br /> 44T <br /> '-�, r UP w,a ueu xi Fr <br /> Tns 3'-6 15,14T ro IIg5 <br /> -1 2030 V-W V-2' 1'-W 15070 GARAGE DOOR .700q= Plc FRO r-u'(%) PORC LINE OF FLOOR ABOVE 405 <br /> 4 68 5F - 27 5F GAS <br /> I AaHrCllpN n.Yc tMWiOu <br /> LJ 0 JINA <br /> 1 <br /> Ia - I I BTL ENGINEERING <br /> � 'E+1 i I IEwm <br /> ION 5EE REVISION LOG <br /> 8'- I' '-5' 2'-01 @' 4-9' 12' I'-II' 15'-3"R.O. °""` <br /> h I w3CALE: Y'-V-O' <br /> 101- 3'-81' 0-9' 19'-Gj' mnwro <br /> - DRIVEWAY <br /> 10' WIDTH 30-0" MAIN FLOOR PLAN <br /> EXTENDED FRONT PORCH <br /> 1_%I /PORCH PLAN OPTION - 'A' ELEV. MAIN FLOOR PLAN - 'A' ELEV. <br /> SCALE: 3/8'-1'-0' SCALE: 1/4'-1'-0' <br />
The URL can be used to link to this page
Your browser does not support the video tag.