0, <br /> EVERETT HOUSING AUTHORITY 0, 1 <br /> SILVER VIEW <br /> Permit#: FA2411-015 <br /> o <br /> L Site Address: 11109 16th Ave SE o <br /> FIRE ALARM SYSTEM z <br /> EVERETT Applicant: Guardian Security = <br /> Everett Fire Dept.Permit Review Application Date: 11/25/2024 cn X <br /> Status:Approved Description: Supply and installation of potter < Q <br /> Reviewed By:kbrown addressable fire alarm system <br /> 12/02/2024 3:59:54 Review Data: 12/02/2024 y w <br /> PM <br /> 11109 16TH AVENUE SE , EVERETT, WASHINGTON 98208 w <br /> oo �- � <br /> N <br /> SHEET No. DESCRIPTION FOR POTTER SYSTEM: a <br /> DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED o <br /> FA-01 SYSTEM INFORMATION WITH DEVICES ADDRESS. <br /> � J <br /> 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT LU <br /> FA-02A TYPICAL WIRING DETAILS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. Cz <br /> 1 FACP . <br /> 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. FIRE ALARM AFC-100 POTTER PROVIDED 66" A F.F. <br /> 0 CONTROL PANEL To TOP <br /> FA-02B TYPICAL DEVICE MOUNTING HEIGHTS 8C 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL 2 NAc REMOTE BOOSTER PSN-106 POTTER PROVIDED 66" A.F.F. <br /> SEQUENCE OF OPERATIONS MATRIX BRANCHING IS PERMISSIBLE POWER SUPPLY TO TOP r <br /> m � <br /> 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL FIRE ALARM 66" A.F.F. <br /> FA-03 SYSTEM CALCULATIONS ELECTRIC CODE, NFPA 72 2019, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 1 FPA ANNUNCIATOR RA-6500FR POTTER PROVIDED To TOP t <br /> 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, Es RADIO <br /> STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) E (1) A COMMUNICATOR 7707P-88—ULP—M AES PROVIDED WALL MOUNT <br /> FA-04 FIRST FLOOR FIRE ALARM PLAN ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. E (EXISTING) NEAR FACP <br /> 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY 1 ® AS BUILT DRAWINGS SS000685 SPACE AGE N/A 66" A.F.F. <br /> FA-05 SECOND FLOOR FIRE ALARM PLAN OUTLETS PER NFPA 72 2019 ANNEX A.17.7.4.1. PHOT <br /> CABINET ELECTRONICS TO TOP Z <br /> 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, 8 Qs SMOKOEELECTRIC SENS R PAD200—PD WITH POTTER 4S DEEP CEILING o 0 <br /> FA-06 THIRD FLOOR FIRE ALARM PLAN TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, (ADDRESSABLE) PAD100-613 BASE W/ 1G RING <br /> AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. _HD WITH w <br /> 84 �F (ADDREDSSABL�) PAD100-6B BASE POTTER Vy/DEEP <br /> RING CEILING w o N <br /> FA-07 RISER DIAGRAM 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED <br /> DRAWINGS FOR "AS BUILT" PURPOSES. MANUAL PULL STATION 4S DEEP 48" A.F.F. <br /> 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT 1 (ADDRESSABLE) PAD100—PSDA POTTER W/ 1G RING To CENTER a <br /> SHEET INDEX SHEETS AND/OR INSTALLATION INSTRUCTIONS. o <br /> ® <br /> 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS 2 DUAL MoouLINPUT PAD100—DIM POTTER 4S DEEP VERIFY LOCATION <br /> E w/ 1c RING N FIELD i <br /> MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND <br /> NFPA 72 2019 10.6.5.1 IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 1 ® SINGLE INPUT PAD100—SIM POTTER W DEEP VERIFY LOCATION <br /> 120voc POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT MODULE W/ 1G RING N FIELD <br /> NORTHWEST ALARM MONITORING SERVICE (NWAMS) DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. <br /> 1743 FIRST AVENUE SOUTH, SEATTLE,WASHINGTON 98134 4 E) RELAY PAD100—RM POTTER 4S DEEP VERIFY LOCATION o <br /> 11. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. MODULE W/ 1G RING IN FIELD <br /> PHONE NUMBER: 206-622-6545 12. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY 1 a MULTI—VOLTAGE MR—tot/C AIR PRODUCTS N/A VERIFY LOCATION o <br /> GENERATOR. CONTROL RELAY IN FIELD z V V <br /> NAME OF CENTRAL MONITORING STATION 13. PER NFPA 72 2019 17.7.1.12.2 WHERE DETECTORS ARE INSTALLED BUT NOT ,,YSZ,,LF LOW FREQUENCY 4S DEEP 80" A.F.F. <br /> OPERATIONAL DURING CONSTRUCTION, THEY SHALL BE PROTECTED FROM 75 IJ AUDIBLE SOUNDER GHLFW GENTEX W/ 1G RING TO BOTTOM <br /> CONSTRUCTION DEBRIS, DUST, DIRT AND DAMAGE IN ACCORDANCE WITH THE LF LOW FREQUENCY 4S DEEP 80" A.F.F. <br /> MANUFACTURERS RECOMMENDATIONS AND VERIFIED TO BE OPERATING IN 6 HORN STROBE GHSLF177W GENTEX W/ 1G RING TO BOTTOM O <br /> ACCORDANCE WITH THE LISTED SENSITIVITY, OR THEY SHALL BE REPLACED PRIOR LLJ <br /> PRIOR TO THE FINAL ACCEPTANCE TEST OF THE SYSTEM. 19 FIRE ALARM GEC3-24WW GENTEX 4S DEEP 80" A.F.F. > <br /> SUPPLY AND INSTALLATION OF POTTER ADDRESSABLE FIRE ALARM SYSTEM 14. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT IJ HORN STROBE W/ 1G RING TO BOTTOM <br /> AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR . II <br /> SCOPE OF WORK F IRE ALARM 4S DEEP 80" A.F.F. <br /> OTHER BACK BOXES OF DIFFERENT CIRCUITS. t2 ' ` STROBE GES3-24WW GENTEX W/ 1G RING To BOTTOM ; <br /> 15. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND FIRE ALARM 4S DEEP J <br /> AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO 3 GCS24CW GENTEX CEILING <br /> STROBE W/ 1G RING <br /> FINAL EQUIPMENT TRIM. C U) <br /> FIRE ALARM WALL MOUNT i CO <br /> WIRE DESIGNATION 16. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A 1wP STROBE WGES24-75WR GENTEX GOELP VERIFY LOCATION 0 <br /> PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. Y (WEATHERPROOF) IN FIELD IJi� <br /> SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE 17. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE FIRE ALARM WALL MOUNT <br /> E (1) �]B E BELL GB10-24 GENTEX EXISTING VERIFY LOCATION W� <br /> Z <br /> OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES (EXISTING) IN FIELD LU LUO O <br /> D DATA LINE — ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP AFTER COMPLETION OF THEIR INSTALLATION. Roots TEMPERATURE VERIFY LOCATION 0 Y Z(~'3 <br /> S STROBE CIRCUIT TWO #14 FPLP 1 © SWITCH RTS-0 POTTER iG BOX IN FIELD = �WZ <br /> 18. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH �_ <br /> T POWER SUPPLY TRIGGER TWO #14 FPLP IT IS LOCATED. 2 Q2 <br /> WATERFLOW VERIFY LOCATION E[z:W <br /> F.B.O. Q SWITCH F.B.O. F.B.O. IN FIELD Q <br /> INITIATION CIRCUIT Two #16 FPLP 19. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. Q Q to 3: <br /> A ANNUNCIATOR DATA TWO #16 FPLP 20. PER IFC 509-1: MOUNT A FIRE ALARM CONTROL PANEL SIGN WITH 2—INCH TAMPER VERIFY LOCATION !rt <br /> P ANNUNCIATOR POWER TWO #14 FPLP WHITE LETTERS ON A RED BACKGROUND LOCATED ON THE OUTSIDE OF THE F.B.O. SWITCH F.B.O. F.B.O. IN FIELD V LL p� <br /> DOOR LEADING TO THE FIRE PANEL LOCATION. Z li r� <br /> DOOR VERIFY LOCATION <br /> F.B.O. F.B.O. F.B.O. r W <br /> DEVICE ADDRESSING MISC. ABBREVIATIONS GENERAL NOTES HOLDER IN FIELD j W <br /> DEVICE ADDRESS DESCRIPTION MISC. DESCRIPTION END—OF—LINE VERIFY LOCATION <br /> SITE LOCATION --- � RESISTOR IN FIELD 0 <br /> X—XXX X= LOOP# E EXISTING TO REMAIN <br /> (SLC ADDRESSABLE DEVICE) XXX = DEVICE# , E' EXISTING <br /> SX—X—X SX= BPS# E DEVICE <br /> (NA ADRESS) X=CIRCUIT# RE RELOCATED EXISTING TO REMAIN N ti;0 FURNISHED <br /> X=DEVICE# °^'^' — "AS""k,. oalrl:.;u --- F.B.O. BY OTHERS LL.I /n <br /> (CANDELA) #=VISUAL CANDELA RATING DEMO EXISTING DEVICE TO BE REMOVED ,.. \W `V}J <br /> VX—X VX= AMP CIRCUIT# m"' / / <br /> w SPEAKER ADDRESS T.B.D TO BE DETERMINED ° W <br /> ( ) X=DEVICE# ••e.8."��"© <br /> o <br /> N <br /> rn (WATTS) #=SPEAKER TAP SETTING A.F.F ABOVE FINISHED FLOOR 'SCALE:NOT r <br /> N <br /> •E.. ° ;G9 o uw7., <br /> IL MISC. ABBREVIATIONS EB.O FURNISHED BY OTHERS DRAWN BY: TO SCALE <br /> >±a MISC. DESCRIPTION G ' D. GARCIA <br /> y o DESIGNED BY: <br /> w T'u N/A NOT APPLICABLE GREEN AS—BUILT REMOVE L. ALLEN <br /> �`` TAHARKA MUHAMMAD DATE:11 20 24 <br /> NICET LEVEL IV BACKROUND PLAN PROVIDED BY <br /> cd� RED AS—BUILT ADD OR CHANGE BLUE AS—BUILT NOTES TO CAD CERT. 138245 EXP. 01/07/2026 JOB NUMBER:76619-1 <br /> 'J A SHEET <br /> W' WIRE DESIGNATION & MISCELLANEOUS INFORMATION VICINITY MAP SYMBOLS LEGEND FA-01 <br /> Proprietary & Confidential, Copyright 2012 b Guardian SecuritySystems, Inc. All Rights Reserved <br />