11109 16TH AVE SE 2024 Plans 2025-08-20
>
Address Records
>
16TH AVE SE
>
11109
>
Plans
>
11109 16TH AVE SE 2024 Plans 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 11:12:39 AM
Creation date
8/20/2025 11:12:19 AM
Metadata
Fields
Template:
Address Document
Street Name
16TH AVE SE
Street Number
11109
Permit
FA2411-015
Year
2024
Notes
SUPPLY AND INSTALLATION OF POTTER ADDRESSABLE FIRE ALARM SYS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0, <br /> EVERETT HOUSING AUTHORITY 0, 1 <br /> SILVER VIEW <br /> Permit#: FA2411-015 <br /> o <br /> L Site Address: 11109 16th Ave SE o <br /> FIRE ALARM SYSTEM z <br /> EVERETT Applicant: Guardian Security = <br /> Everett Fire Dept.Permit Review Application Date: 11/25/2024 cn X <br /> Status:Approved Description: Supply and installation of potter < Q <br /> Reviewed By:kbrown addressable fire alarm system <br /> 12/02/2024 3:59:54 Review Data: 12/02/2024 y w <br /> PM <br /> 11109 16TH AVENUE SE , EVERETT, WASHINGTON 98208 w <br /> oo �- � <br /> N <br /> SHEET No. DESCRIPTION FOR POTTER SYSTEM: a <br /> DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED o <br /> FA-01 SYSTEM INFORMATION WITH DEVICES ADDRESS. <br /> � J <br /> 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT LU <br /> FA-02A TYPICAL WIRING DETAILS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. Cz <br /> 1 FACP . <br /> 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. FIRE ALARM AFC-100 POTTER PROVIDED 66" A F.F. <br /> 0 CONTROL PANEL To TOP <br /> FA-02B TYPICAL DEVICE MOUNTING HEIGHTS 8C 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL 2 NAc REMOTE BOOSTER PSN-106 POTTER PROVIDED 66" A.F.F. <br /> SEQUENCE OF OPERATIONS MATRIX BRANCHING IS PERMISSIBLE POWER SUPPLY TO TOP r <br /> m � <br /> 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL FIRE ALARM 66" A.F.F. <br /> FA-03 SYSTEM CALCULATIONS ELECTRIC CODE, NFPA 72 2019, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 1 FPA ANNUNCIATOR RA-6500FR POTTER PROVIDED To TOP t <br /> 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, Es RADIO <br /> STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) E (1) A COMMUNICATOR 7707P-88—ULP—M AES PROVIDED WALL MOUNT <br /> FA-04 FIRST FLOOR FIRE ALARM PLAN ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. E (EXISTING) NEAR FACP <br /> 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY 1 ® AS BUILT DRAWINGS SS000685 SPACE AGE N/A 66" A.F.F. <br /> FA-05 SECOND FLOOR FIRE ALARM PLAN OUTLETS PER NFPA 72 2019 ANNEX A.17.7.4.1. PHOT <br /> CABINET ELECTRONICS TO TOP Z <br /> 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, 8 Qs SMOKOEELECTRIC SENS R PAD200—PD WITH POTTER 4S DEEP CEILING o 0 <br /> FA-06 THIRD FLOOR FIRE ALARM PLAN TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, (ADDRESSABLE) PAD100-613 BASE W/ 1G RING <br /> AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. _HD WITH w <br /> 84 �F (ADDREDSSABL�) PAD100-6B BASE POTTER Vy/DEEP <br /> RING CEILING w o N <br /> FA-07 RISER DIAGRAM 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED <br /> DRAWINGS FOR "AS BUILT" PURPOSES. MANUAL PULL STATION 4S DEEP 48" A.F.F. <br /> 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT 1 (ADDRESSABLE) PAD100—PSDA POTTER W/ 1G RING To CENTER a <br /> SHEET INDEX SHEETS AND/OR INSTALLATION INSTRUCTIONS. o <br /> ® <br /> 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS 2 DUAL MoouLINPUT PAD100—DIM POTTER 4S DEEP VERIFY LOCATION <br /> E w/ 1c RING N FIELD i <br /> MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND <br /> NFPA 72 2019 10.6.5.1 IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 1 ® SINGLE INPUT PAD100—SIM POTTER W DEEP VERIFY LOCATION <br /> 120voc POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT MODULE W/ 1G RING N FIELD <br /> NORTHWEST ALARM MONITORING SERVICE (NWAMS) DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. <br /> 1743 FIRST AVENUE SOUTH, SEATTLE,WASHINGTON 98134 4 E) RELAY PAD100—RM POTTER 4S DEEP VERIFY LOCATION o <br /> 11. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. MODULE W/ 1G RING IN FIELD <br /> PHONE NUMBER: 206-622-6545 12. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY 1 a MULTI—VOLTAGE MR—tot/C AIR PRODUCTS N/A VERIFY LOCATION o <br /> GENERATOR. CONTROL RELAY IN FIELD z V V <br /> NAME OF CENTRAL MONITORING STATION 13. PER NFPA 72 2019 17.7.1.12.2 WHERE DETECTORS ARE INSTALLED BUT NOT ,,YSZ,,LF LOW FREQUENCY 4S DEEP 80" A.F.F. <br /> OPERATIONAL DURING CONSTRUCTION, THEY SHALL BE PROTECTED FROM 75 IJ AUDIBLE SOUNDER GHLFW GENTEX W/ 1G RING TO BOTTOM <br /> CONSTRUCTION DEBRIS, DUST, DIRT AND DAMAGE IN ACCORDANCE WITH THE LF LOW FREQUENCY 4S DEEP 80" A.F.F. <br /> MANUFACTURERS RECOMMENDATIONS AND VERIFIED TO BE OPERATING IN 6 HORN STROBE GHSLF177W GENTEX W/ 1G RING TO BOTTOM O <br /> ACCORDANCE WITH THE LISTED SENSITIVITY, OR THEY SHALL BE REPLACED PRIOR LLJ <br /> PRIOR TO THE FINAL ACCEPTANCE TEST OF THE SYSTEM. 19 FIRE ALARM GEC3-24WW GENTEX 4S DEEP 80" A.F.F. > <br /> SUPPLY AND INSTALLATION OF POTTER ADDRESSABLE FIRE ALARM SYSTEM 14. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT IJ HORN STROBE W/ 1G RING TO BOTTOM <br /> AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR . II <br /> SCOPE OF WORK F IRE ALARM 4S DEEP 80" A.F.F. <br /> OTHER BACK BOXES OF DIFFERENT CIRCUITS. t2 ' ` STROBE GES3-24WW GENTEX W/ 1G RING To BOTTOM ; <br /> 15. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND FIRE ALARM 4S DEEP J <br /> AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO 3 GCS24CW GENTEX CEILING <br /> STROBE W/ 1G RING <br /> FINAL EQUIPMENT TRIM. C U) <br /> FIRE ALARM WALL MOUNT i CO <br /> WIRE DESIGNATION 16. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A 1wP STROBE WGES24-75WR GENTEX GOELP VERIFY LOCATION 0 <br /> PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. Y (WEATHERPROOF) IN FIELD IJi� <br /> SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE 17. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE FIRE ALARM WALL MOUNT <br /> E (1) �]B E BELL GB10-24 GENTEX EXISTING VERIFY LOCATION W� <br /> Z <br /> OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES (EXISTING) IN FIELD LU LUO O <br /> D DATA LINE — ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP AFTER COMPLETION OF THEIR INSTALLATION. Roots TEMPERATURE VERIFY LOCATION 0 Y Z(~'3 <br /> S STROBE CIRCUIT TWO #14 FPLP 1 © SWITCH RTS-0 POTTER iG BOX IN FIELD = �WZ <br /> 18. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH �_ <br /> T POWER SUPPLY TRIGGER TWO #14 FPLP IT IS LOCATED. 2 Q2 <br /> WATERFLOW VERIFY LOCATION E[z:W <br /> F.B.O. Q SWITCH F.B.O. F.B.O. IN FIELD Q <br /> INITIATION CIRCUIT Two #16 FPLP 19. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. Q Q to 3: <br /> A ANNUNCIATOR DATA TWO #16 FPLP 20. PER IFC 509-1: MOUNT A FIRE ALARM CONTROL PANEL SIGN WITH 2—INCH TAMPER VERIFY LOCATION !rt <br /> P ANNUNCIATOR POWER TWO #14 FPLP WHITE LETTERS ON A RED BACKGROUND LOCATED ON THE OUTSIDE OF THE F.B.O. SWITCH F.B.O. F.B.O. IN FIELD V LL p� <br /> DOOR LEADING TO THE FIRE PANEL LOCATION. Z li r� <br /> DOOR VERIFY LOCATION <br /> F.B.O. F.B.O. F.B.O. r W <br /> DEVICE ADDRESSING MISC. ABBREVIATIONS GENERAL NOTES HOLDER IN FIELD j W <br /> DEVICE ADDRESS DESCRIPTION MISC. DESCRIPTION END—OF—LINE VERIFY LOCATION <br /> SITE LOCATION --- � RESISTOR IN FIELD 0 <br /> X—XXX X= LOOP# E EXISTING TO REMAIN <br /> (SLC ADDRESSABLE DEVICE) XXX = DEVICE# , E' EXISTING <br /> SX—X—X SX= BPS# E DEVICE <br /> (NA ADRESS) X=CIRCUIT# RE RELOCATED EXISTING TO REMAIN N ti;0 FURNISHED <br /> X=DEVICE# °^'^' — "AS""k,. oalrl:.;u --- F.B.O. BY OTHERS LL.I /n <br /> (CANDELA) #=VISUAL CANDELA RATING DEMO EXISTING DEVICE TO BE REMOVED ,.. \W `V}J <br /> VX—X VX= AMP CIRCUIT# m"' / / <br /> w SPEAKER ADDRESS T.B.D TO BE DETERMINED ° W <br /> ( ) X=DEVICE# ••e.8."��"© <br /> o <br /> N <br /> rn (WATTS) #=SPEAKER TAP SETTING A.F.F ABOVE FINISHED FLOOR 'SCALE:NOT r <br /> N <br /> •E.. ° ;G9 o uw7., <br /> IL MISC. ABBREVIATIONS EB.O FURNISHED BY OTHERS DRAWN BY: TO SCALE <br /> >±a MISC. DESCRIPTION G ' D. GARCIA <br /> y o DESIGNED BY: <br /> w T'u N/A NOT APPLICABLE GREEN AS—BUILT REMOVE L. ALLEN <br /> �`` TAHARKA MUHAMMAD DATE:11 20 24 <br /> NICET LEVEL IV BACKROUND PLAN PROVIDED BY <br /> cd� RED AS—BUILT ADD OR CHANGE BLUE AS—BUILT NOTES TO CAD CERT. 138245 EXP. 01/07/2026 JOB NUMBER:76619-1 <br /> 'J A SHEET <br /> W' WIRE DESIGNATION & MISCELLANEOUS INFORMATION VICINITY MAP SYMBOLS LEGEND FA-01 <br /> Proprietary & Confidential, Copyright 2012 b Guardian SecuritySystems, Inc. All Rights Reserved <br />
The URL can be used to link to this page
Your browser does not support the video tag.